耐火物
Online ISSN : 2759-3835
Print ISSN : 0039-8993
MgO-Cれんがにおける酸化試験方法の改良
市川 健治西尾 英昭星山 泰宏
著者情報
ジャーナル フリー

1993 年 45 巻 3 号 p. 128-135

詳細
抄録
Oxidation test using an air atmosphere electric furnace which is usually used for gaseous phase oxidation test was made verification.In this test,maximum error of weight loss by oxidation of carbon reached 30 percent when a space of samples was 30mm,It is inferred that a main cause of the error is distribution of oxygen concentration in the furnace.  We introduced a bottom rotating electric furnace to improve the gaseous phase oxidation test and tried it. As a result,error of weight loss was less than ± 1%.  Measured values of oxidation rate agreed well with a rate equation which was submitted by us,and it was cleared that oxidation rate of MgO-C bricks was dominated by laminar film and decarbonized layer.
著者関連情報
© 1993 耐火物技術協会