種々な方法によるMn-Si-C鋼の残留オーステナイト体積率測定の比較
友田 陽関戸 信彰徐 平光川崎 卓郎ハルヨ ステファヌス田中 雅彦篠原 武尚蘇 玉華谷山 明
著者情報
ジャーナル オープンアクセス HTML

2017 年 103 巻 10 号 p. 570-578

詳細
抄録

Various methods were employed to measure the austenite volume fraction in a 1.5Mn-1.5Si-0.2C steel. It has been confirmed that the volume fractions determined by transmission electron microscopy, scanning electron microscopy/electron back scatter diffraction, X-ray diffraction and neutron diffraction exhibit a general trend to become larger in this order, although the values obtained by X-ray and neutron diffraction are similar in the present steel because austenite is relatively stable. The austenite volume fractions determined by diffraction methods have been found to be affected by the measuring specimen direction, i.e., texture, even by applying the conventional correcting procedure. To avoid this influence, it is recommended to measure both of volume fraction and texture simultaneously using neutron diffraction. Although synchrotron X-ray shows higher angle resolution, its small incident beam size brings poor statistic reliability. The influence of texture cannot be avoided for transmission Bragg edge measurement, either, which must be overcome to realize 2D or 3D volume fraction mapping.

著者関連情報
© 2017 一般社団法人 日本鉄鋼協会

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/