Microbiologically Influenced Corrosion of SUS304L and SUS316L Welds Caused by Aerobic and Anaerobic Bacteria in Groundwater (I)
Laboratory Simulation Studies and Corrosion Behavior
Yasushi KIKUCHI, Masayoshi OZAWA, Kenji TOHMOTO, Hideto ONISHI, Takeshi SAKANE, Toshio ANZAI
Author information
JOURNAL OPEN ACCESS

2002 Volume 88 Issue 10 Pages 658-663

Details
Abstract
Microbiologically influenced corrosion was suspected in a corrosion failure of stainless steel (SUS316L) piping, carrying saline groundwater. Laboratory simulation studies were planned to find out the mechanism of the corrosion. The groundwater from the same plant was transferred to the laboratory aseptically and used for the experiment. Both SUS316L and SUS304L welds (base metal, heat affected zone, weld metal) were exposed to the test solution. After 40 d, corrosion sites were observed on the surface of coupons exposed to non-sterile groundwater supplemented with nutrients. In case of both sterile and non-sterile groundwater devoid of nutrient, the corrosion sits were not observed. Therefore, it is assumed that the corrosion occurrence requires bacteria, their activity and metabolism. The form of corrosion was pitting for base metal and heat affected zone, whereas, weld metal showed skeletal corrosion caused by preferential attack on γ-austenite.
Generally, the pH showed no change during exposure test. The potential increased during exposure to nutrient contained non-sterile groundwater for all coupons. In the case of both sterile and non-sterile groundwater devoid of nutrient, the potential did not show an increase for all the coupons. The potential increase that is influenced by bacteria is assumed to be the reason for the easy occurrence of corrosion.
Content from these authors
© The Iron and Steel Institute of Japan

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top