CO2ヒートポンプ給湯システムにおける給湯方式を考慮した貯湯量の評価
横山 良平安東 丈晴平良 繁治
著者情報
ジャーナル フリー

2013 年 30 巻 1 号 p. 31-42

詳細
抄録

Attention has been paid to the enhancement of the performance of CO2 heat pump water heating systems. One of the ways to increase the heat pump coefficient of performance (COP) and system efficiency as well as the volumes of stored and unused hot water is to revise the system by extracting water with middle temperatures from the middle of the storage tank, and the performance of the revised system has been evaluated by numerical simulation. However, the volumes of stored and unused hot water have been evaluated in a conventional method. In this paper, they are evaluated in consideration of hot water supply procedure. An evaluation method by numerical analysis of differential equations is proposed to take account of the discontinuities of the temperature in the storage tank. Through evaluation examples, it turns out that the volumes of stored and unused hot water are evaluated accurately and efficiently in all the cases by the proposed method. In addition, it is clarified how the volumes of stored and unused hot water evaluated by the proposed method differ from those by the conventional method.

著者関連情報
© 2013 公益社団法人 日本冷凍空調学会