Transactions of the Materials Research Society of Japan
Online ISSN : 2188-1650
Print ISSN : 1382-3469
ISSN-L : 1382-3469
Regular Papers
Wear test and Raman analysis of diamond-like carbon films prepared by bipolar-type plasma based ion implantation
S. NakaoN. TerayamaS. UedaD. SasakuraY. FujimakiA. Motoi
著者情報
ジャーナル フリー

2011 年 36 巻 3 号 p. 333-336

詳細
抄録
Diamond-like carbon (DLC) films are prepared on hard metal (WC-Co) substrates by a bipolar-type plasma based ion implantation. The mechanical properties and structural changes are examined by wear test and Raman spectroscopy as a function of negative pulse voltages (Vn) in the range of -5 to -15 kV. It is found that friction coefficient is around 0.2 for each sample. However, lower Vn causes better endurance (longer steady wear distance). Raman measurements reveal that the microstructure is changed to graphite-like structure after wear test. It is assumed that the degree of graphitization is larger as Vn increases.
著者関連情報
© 2011 The Materials Research Society of Japan
前の記事 次の記事