日本機械学会論文集
Online ISSN : 2187-9761
ISSN-L : 2187-9761
熱工学,内燃機関,動力エネルギーシステム
多孔質金属フィンの圧力損失と熱伝達率の予測法
近藤 義広越田 博之
著者情報
ジャーナル フリー

2016 年 82 巻 844 号 p. 16-00173

詳細
抄録

In order to evaluate the cooling performance of the porous metal fins, both the friction factor and heat transfer coefficient were taken into account. In this study, we compared six porous metal fins and four kinds of heat exchangers made of porous material. Moreover, we proposed a new model which predicts the cooling performance of the porous metal fins. Friction loss factor of porous metal fins became predictable in less than ±10% error by using effective cross-sectional flow area and Ergun coefficient in Forchheimer-extended Darcy model. Heat transfer coefficient of porous metal fins can be predicted within an error of 10% by our model. The predictive model has two assumptions. One is that the perimeter in the porous metal fin per cross-sectional area of porous metal fin is independent of the heights of fins and number of porous cells. Another assumption is that heat transfer coefficient of porous metal fin is also independent of the heights of fins and number of porous cells as long as the velocity is same.

著者関連情報
© 2016 一般社団法人日本機械学会