トライボロジスト
Online ISSN : 2189-9967
Print ISSN : 0915-1168
ISSN-L : 0915-1168
学術論文
電気鉄道における集電材料の通電による溶融体積の推定手法
山下 主税根本 公紀小原 拓也
著者情報
ジャーナル フリー

2022 年 67 巻 5 号 p. 366-372

詳細
抄録

In order to suppress electric wear of current collecting materials such as a contact wire and a contact strip in an electric railway, it is necessary to estimate the relationship between current and melting volume at a contact loss point. In this paper, we focused on a molten bridge which is considered as the main factor of electric wear at the contact loss point. And we proposed the estimation method of melting volume of contact wire and contact strip; in which film resistance is considered by using the relationship between the electric potential and the temperature at the contact spot. From estimation results, it is found that the melting volume increases as current increases, and that it increases as a contact boundary factor decreases. In addition, the authors carried out wear tests and measured a melting depth, a melting radius, and a melting volume under two conditions of current. From wear test results, experimental values of melting volume of the contact wire were in the range where contact boundary factor α was estimated from 0.90 to 0.94.

著者関連情報
© 2022 一般社団法人 日本トライボロジー学会
前の記事 次の記事
feedback
Top