日本建築学会論文報告集
Online ISSN : 2433-0027
Print ISSN : 0387-1185
ISSN-L : 0387-1185
325 巻
選択された号の論文の23件中1~23を表示しています
  • 原稿種別: 表紙
    1983 年 325 巻 p. Cover1-
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
  • 原稿種別: 表紙
    1983 年 325 巻 p. Cover2-
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
  • 原稿種別: 目次
    1983 年 325 巻 p. Toc1-
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
  • 原稿種別: 目次
    1983 年 325 巻 p. Toc2-
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
  • 日置 興一郎
    原稿種別: 本文
    1983 年 325 巻 p. 1-8
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    The effective strength is defined as the strength of the equivalent continuum and derived for the rigidly connected lattice structures which subjected to the elastic buckling of constituent members. Main conclusions are as follows. The intensity of the effective strength of a rigidly connected truss is between one and four times of that of the pin jointed truss of the same members if the latter is stable. The instability pattern unit appears on a few of structural units and may change according to the stress states. For example, in-plane three-way lattice, in-plane parallel chord trusses, and a double-layer lattice plate are treated. By using the effective strength, the structural design becomes easy especially for rigidly connected trusses. Also, the next theorem has been proved and used. The matrix of the equilibrium equation for lattice structures in difference expression is the transposed matrix of that of the compatibility equation by changing the sign of the power of the shift operator, and vice-versa.
  • 柴田 道生, 若林 實
    原稿種別: 本文
    1983 年 325 巻 p. 9-16
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    An elastic-plastic analysis was performed on the hysteretic behavior of a steel braced frame subjected to repeated horizontal load. Each member was assumed to be composed of three elastic-plastic springs and two straight segments. The relative rotation of the spring was dependent on the moment-curvature relationship of individual member. The governing equations included the second order terms of the large deflection of brace members, and the optimum increment of load and deformation parameters were obtained by solving the second order simultaneous equations. The computed results on the K-type braced frame reasonably agreed with the experimental results, and derived following conclusions. 1) The beam in K-type braced frame is subjected to the lateral force which is the sum of the vertical components of the axial forces of braces. The hysteretic characteristics of the system much depends on the elastic-plastic behavior of the beam, because the brace can not hold its full strength when the beam yields in bending by the lateral force caused by braces. 2) If the weak beam and stubby braces are combined, the large plastic deformation of the beam causes the severe deterioration of the hysteresis loop. 3) The lateral registance of the beam can be estimated by Q_<g0>=2M_<g0>/l_g, where M_<g0> and l_g is the full plastic moment and the clear span of the beam, respectively.
  • 金多 潔, 甲津 功夫
    原稿種別: 本文
    1983 年 325 巻 p. 17-24
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    H形鋼からなる鋼構造はり端部が, 繰り返し弾塑性曲げを受ける場合に, その局所のひずみ挙動と低サイクル疲労特性を明らかにするための基礎的な研究として, SS41, 圧延H-200×100×5.5×8はり部材から成る片持ばり型試験体を用いた定変位制御繰り返し実験を行った。本研究で得られた主な結果は, 1)はり端フランジ部のひずみは, 溶接熱履歴により大きな影響を受けるけれども, 繰り返し載荷に伴って, その履歴形状は安定し収束する傾向にあった。また, フランジ幅方向のひずみは, 履歴の安定する2サイクル目以降で, 中央部と両縁部で特に大きな差は見られなかった。はり端部のひずみ挙動のこのような特徴から, はり先端(自由端)の変位制御実験は, はり端(固定端)フランジのひずみ制御実験に対応することがわかる。2) 1)で述べたはり端フランジのひずみ挙動に着目して, 疲労強度実験式を求めることができる。本研究でははり端フランジ部のひずみの平均値に基づいて, Manson-Coffin流の指数近似式を導いた。はり端部の応力集中などの影響により, 本試験体の疲労強度は, 鋼素材の疲労強度と比較して大幅に低下することが示され, その疲労強度低下率は, 約1/4〜1/5程度となることがわかった。なお, 素材レベルの疲労実験結果との厳密な比較は, はり端フランジのスカーラップ止端部におけるひずみ集中を明確に把握して論ずるべきであるが, 本論ではこの点に関する資料を整備することができなかった。基礎模型実験と実構造物または実構造物を反映したモデルによる疲労実験の関連性と, 鋼構造物の疲労強度を予測するための基礎模型実験結果の適用性に関する研究としては, たとえば文献8), 9)などがあるが, 未だ基本段階であり, 今後この方面の研究が必要であるものと思われる。
  • 阿部 一孝, 田川 健吾, 坂井 正美
    原稿種別: 本文
    1983 年 325 巻 p. 25-31
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    The elasic-plastic behavior of the working stress designed full-scale gable frame against symmetrically vertical load was observed, and was examined using the theories of Part (I) and Part (II) in this study. In this test, the gable frame showed the asymmetrical by swayed elastic-plastic buckling mode before symmetrical failure without showing a local or lateral buckling. This failure load could not be predicted by the theory that we reported in Part (I), for the value of W_<cr>/W_e was below the transition line. This failure mode was, however, well predicted by the theory of Part (II) in which we considered the deteriorated effect of yielding regions, and the critical value of W_<cr>/W_e of this frame was plotted within expanded the transition area in Part (II).
  • 田沼 吉伸, 加藤 勉, 森田 耕次
    原稿種別: 本文
    1983 年 325 巻 p. 32-39
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    Many braced steel buildings were damaged heavily by the 1978 Miyagiken-oki Earthquake owing to the premature failure at the joints of brace-to-gusset plate. From the view point of aseismic design of braced steel frames, the jointed part of the braced may not break before the bracing member itself does yield at its gross section. Therefore, it is important to estimate the maximum strength of brace joints. In this paper, the results of experiments on the joints of brace-to-gusset plate whose experimental variables are size of member elements (size of steel angle and gusset plate), joint type (single or double friction-bolted joints), and joint details (numbers, pitch and edge distance of high strength bolts) ape reported. Considering the key parameters which are influential in the joint strength, an experimental formula of the maximum strength of the brace joints is derived by the multiple regression analysis of the test results. Based on this estimated formula of maximum strength, the practical design formula which satisfies the aseismic requirement is obtained on the basis of statistical view point.
  • 藤本 盛久, 大熊 武司, 赤木 久真, 田村 哲郎
    原稿種別: 本文
    1983 年 325 巻 p. 40-46
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    Deardorffモデルに基づく乱流の数値解析法を用いて, いくつかの辺長比をもつ長方形断面角柱に風が作用する場合を想定した二次元非定常数値解析をおこなった。得られた主要な結果はつぎのとおりである。(1)角柱後流における平均逆流域は, 奥行/幅=2付近で最も大きくなり, 既往の実験結果と同様の傾向にある。(2)角柱後流では角柱の辺長比, 後流の位置によらず平均流速欠損分布に相似性がほぼ成立している。(3)ストローハル数は, 辺長比の違いによる特徴的な変化をはじめ, レイノルズ数が十分に大きい場合の既往の実験結果に近い値を示している。(4)角柱表面の圧力係数および角柱の抗力係数, 揚力係数は, 平均分変動分とも辺長比による変化の傾向については既往の実験結果の傾向と類似している。以上より, 本研究で提示した数値解析法は, 角柱の周辺気流および表面圧力の辺長比の違いによる変化を, 今回の解析程度の計算格子点数の制約下においても定性的には表現し得る方法であるといえ, 将来的にはこの種の現象解明に有望な方法であることが示唆される。
  • 角野 晃二, 小沢 善隆
    原稿種別: 本文
    1983 年 325 巻 p. 47-56
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    Elastic instability of simply supported spherical shells subjected to the quasi-static exernal pressure under both immovable and movable boundary conditions (including the relaxation of edge constraint) has been studied. Numerical calculation has been performed by means of new basic equations expressed in terms of deflections u, v, w, and two independent shell parameters a/h, β, which take account of the follwer force. Results obtained here have been compared with previous results and the effect of the relaxation to the instability of shells have been expressed. Finally, both snap-through and bifurcation buckling pressure were lowerd by the effects of the relaxation of edge constraint, especially decreasing of the snap-through buckling pressure is remarkable. So, it can be said that the instbility of simply supported spherical shells not always arise the bifurcation buckling in the region 0.22<β(5<α).
  • 国枝 治郎
    原稿種別: 本文
    1983 年 325 巻 p. 57-66
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
  • 上場 輝康, 金谷 弘, 藤原 勝義, 田渕 基嗣
    原稿種別: 本文
    1983 年 325 巻 p. 67-73
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    The present paper is on the local failure of tubular column to H-beam connections stiffened with ring stiffeners. On the basis of the test results reported in the preceeding paper (Ref. 1) which described a number of simplified model tests of the connections, the empirical formulae predicting the local strength of connections are derived by the dimensional analysis and the regression analysis. The empirical formulae obtained here are as follows : For the maximum load, [numerical formula]…(4) For the yield load, P_<cy>=0.65P_<cmax> The relationships between the value calculated from Eq. (4) and the test results are shown in Fig. 3. The limitations for using these formulae are D/tp=18〜54, h_s/R=0.14〜0.42, t_s/t_p=0.75〜2.25 and B_f/D=0.35〜0.63, and where the material properties of the ring stiffener and beam flanges are nearly equal to those of the tubular columns. In the practical connections, P=M_b/H_b shall be used.
  • 村上 周三, 岩佐 義輝, 森川 泰成
    原稿種別: 本文
    1983 年 325 巻 p. 74-84
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    本研究は, 長期にわたって行われた風観測と住民意識調査の結果に基づいて風環境評価尺度の作成を試みたものである。本研究結果を要約すると以下のようになる。(1)一日全体の風環境評価を6段階に分類し, 各々の評価と風速値(日最大平均風速, 日最大瞬間風速)との関連を分析した。(2)特に, 一日全体の風環境評価として居住者が「風の強い日」という認識をし始めるのは, 日最大平均風速で約4.0m/s, 日最大瞬間風速で約10.0m/sである。(3)風によって発生する代表的な環境障害を12項目選び, 各々について瞬間風速値との関連を示した。さらに対応する風速値に応じてこれらの障害を次の3グループに分類した。(i)時間最大瞬間風速5.0〜9.0m/sで発生する障害(髪や衣服が乱れる, ごみが舞上る等), (ii) 9.0〜12.0m/sで発生する障害(建具が音をたてる, 立看板が倒れる等), (iii) 12.0〜15.0m/sで発生する障害(歩行中吹き飛ばされそうになる等)。(4)一日全体の風環境評価の決定は, その日生じた環境障害に大きく影響されることを確認し, 両者の対応関係を分析した。以上より, 各評価段階と一日を代表する風速値, 及びそのような日に発生すると予想される環境障害とを対応づけ, 一日単位の総合的な風環境を知るための図表を作成した。これより強風に関しては日最大瞬間風速10, 15, 20m/sが一日の風環境評価を行うための代表的な指標であることを示した。(5)市街地における風環境評価尺度としては, 風速出現頻度の概念が必要不可決であり, 上記(1)〜(4)の結果を基に風速出現頻度に基づく風環境評価尺度を作成した。この尺度は風の影響の受けやすさの程度をその空間の使用目的により3段階に分類し, 各々に対する風速の許容出現日数を設定したものである。(6)風洞実験により市街地の風環境評価を行う手法について述べ, 実際に都下の3市街地に対して上記の評価尺度を適用し風環境の評価を行った。さらに, 既往の評価方法による結果とも比較検討し, 本評価尺度の有効性を大まかに確認した。これらの分析結果や筆者等が提案した尺度は市街地低層部で生じた限られた調査結果に基づくものであり, 必ずしも十分なものとは言えない。今後より多くの実例に適用し, また関係各位の御教示, 御批判を得て改善してゆきたいと考えている。
  • 篠原 道正, 早川 一也
    原稿種別: 本文
    1983 年 325 巻 p. 85-92
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    This paper intended to obtain basic data of the index for the design of thermal environment, based on the heat balance equation of the human body. For this purpose, the hemispherical emissivity was introduced as the emissivity of finishing materials. The hemispherical emissivity agree with normal emissivity for most finishing materials, but does not agree for the glass plate This was confirmed by preliminary experiment. But the idea of the hemispherical emissivity is not convenience for the building materials. Then the radiative temperature was introduced, which was the temperature considered effect of the hemispherical emissivity. The radiative temperature were measured for any finishing materials by new apparatus for radiative temperature. From these experiment, it was appeared that the radiative temperature of the glass plate did not agree with the surface temperature by the thermocouple because the hemispherical emissivity was smaller than the normal emissivity. The radiative temperature of complex material of glass plate with drape were examined, too, and evaluated mechanism of heat transfer.
  • 浦野 良美, 渡辺 俊行
    原稿種別: 本文
    1983 年 325 巻 p. 93-103
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    The heat balance equation at a wall surface is composed of the following terms; (1) heat conduction, (2) convective heat transfer, (3) short-wave radiation, (4) long-wave radiation and (5) mass transfer. This equation is very important in determining boundary conditions of a wall heat conduction problem. When mass transfer is negligible, the sensible heat balance at a roof surface can be measured by making use of instruments such as pyranometers, improved polyethylene-shielded pyrradiometers, heat flow meter panels and copper-constantan thermo-couples. The method of measurement and its accuracy are discussed in section 4, covering (1) atmospheric radiation, (2) total net radiation, (3) the absorptance of the surface for solar radiation, (4) the emittance of the surface, (5) convective heat transfer coefficient α_c and so on. By using several kinds of sol-air temperatures obtained from field experimental data, the thermal response of a roof slab is simulated by the successive calculation method which was already proposed in the previous paper. When the film coefficient α is regarded as a time variable parameter, i.e. α_n, based on the experimental data, then, for the temperature and the heat flow rate at the outside surface, the standard deviation of the calculated values from the experimental ones reduces to half respectively, as compared with the case of its time dependence neglected. Although this result is no more than an example, it is said that the accuracy of the analysis can be apparently improved by regarding α as a time variable parameter. Then the value of α_<c, n> may be smaller as the surface becomes larger.
  • 村上 周三, 吉野 博
    原稿種別: 本文
    1983 年 325 巻 p. 104-115
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    住宅の気密性能に関する昭和36年以後の研究報告を一覧にして表-1に示す。わが国ではすでに大正13年に野村が, また昭和3年に大谷が室に存在する隙間の換気に及ぼす影響を実験的に検討しており, 隙間の量を部位別に目測し, その結果を示している。渡辺は, それらの結果を基に, 室容積1m^3当りの隙間面積が, 木造真壁造の和室では構造が粗の場合90cm^2以上, 中の場合60〜50cm^2, 密の場合30cm^2以下であり, コンクリート造の洋室では, 10〜15cm^2であることを述べている。その後, 昭和36年に, 前田, 石原等はコンクリート造集合住宅を対象として部位別の気密性能を減圧法(後述)により初めて定量的に測定した。最近では, 楢崎等が単室及び数室の気密性能及び防音実験住宅の気密性能を, 筆者らは各種住宅25戸を対象に, 市川等は集合住宅を, 浅野は各種住宅10戸を, 旭ダウ(株)の研究グループは北海道の断熱改修もあった。これはサッシの隙間の約3倍の量に達する。また, 3つの集合住宅における部位別のαAを比較した結果, 目につかない隙間は28〜126cm^2と大幅に異った。(3)建物に設置された後のサッシの気密性能は, 本来備わっているはずの性能よりもはるかに劣ることがある。今回測定した中では, Q_<l0>が, 性能試験値の6倍に達するものもあった。(4)住宅全体の気密性能を, 単位床面積当りの隙間の相当開口面積によって表し, 既往の測定結果を含めてグレード表に位置づけた結果, 各国における気密性能の水準が明らかとなり, わが国における気密性能の目標水準を設定するための手がかりを得ることができた。(5)気密性能の異なる3つの集合住宅において, 既設の台所換気扇を運転し室内圧を測定したところ, αAが2.4cm^2/m^2である防音気密住宅の場合, 排気量360m^3/hで-12.8mmAqにも下がった。この住宅で便所系統の換気扇を同時運転したところ, 便所系統のダクトから逆流が生じた。気密住宅において, 逆流やドア開閉時のトラブルを考慮して, 室内圧低下を-4mmAq程度にとどめるためには, 給気ダクトの径を175〜200mmにする必要のあることが, 実測及び数値計算より明らかとなった。
  • 阿部 成治
    原稿種別: 本文
    1983 年 325 巻 p. 116-124
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    Shadow regulations are considered not only to affect building forms not to cause shadow, but also to decrease rates of building volumes to lots. Accordingly, three building types are selected and rates of building volumes are computed according to various building lengths, widths, orientations, stories and three kinds of shadow regulations. As shadows vary by latitude, 35 degrees of latitude is selected, and building volumes on 32 degrees is also compared with those on 35 degrees. It is concluded that shadow regulations affect to decrease building volumes, except the cases in which shadow regulation (1) is designated in relation to rates of building volumes of 100%. And effects of shadow regulations are strong when the dwelling conditions of building itself are desirable. That is to say, under shade regulations, building volumes must by decreased in order to obtain good dwelling conditions.
  • 位寄 和久
    原稿種別: 本文
    1983 年 325 巻 p. 125-132
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    In case of evaluating whether an architectural planning is adequate for users, it needs to consider users' behaviour under two cases of environment condition. One case is the normal condition, and the other is abnormal condition such as fire, earthquake or other disaster. In this paper, a fire evacuation model, which is one of the case under the abnormal condition, is proposed in order to estimate building layouts from the view of users' security. This model predicts users' behaviour evacuating from building on fire and estimates the safety zone or floor planning of stairs or exit. One of typical exhibition hall of the department store is examined as an example of simulation of this model using computer. There are two remarkable characteristics in this model. The first one is that the process of users' evacuation is separated in two segments. First segment is one from the occurence of fire till users' perception of fire and the second segment is from perception of fire till the successful finish of evacuation or failure of evacuation. The second characteristic is in the process of the way of users' evacuation from fire. Each indivisual decide his behaviour according to his situation which is brought by his own character and his psychological state at that time. Representing the floor plan into square grids, it became possible to examine thoroughly the relationship between users' evacuation and the layout of showcase, column, exit, etc. By using this model, the users' psychological state and the users' real action can be simulated. So this model will help to comprehend the human evacuation process which had been difficult to understand.
  • 吉田 高子
    原稿種別: 本文
    1983 年 325 巻 p. 133-143
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    There were 149 carpenters in the Furuhashi party in 1779 and the number increased up to 353 persons in 1863. One of the causes of the increase in number was because the carpenter pupils grew larger. Another cause was found in that the number of Komori-pupils and sons working under their boss-was oditionally included in the number. The increase of construction work also influenced the number of carpenters. Most of the customers the Furuhashi party took orders were living in the same village or district where their carpenters under patronage dwelled. In 1855 the Furuhashi party carpenters worked for the reconstruction of Kyoto Imperial Palace together with other party carpenters from six different countries. In the case of Furuhashi party, the carpenters who were engaged in the reconstruction work were chosen by each Moyori and sent to work in turn. In each Moyori district, therefore, they seldom had any stopage or delay in their work.
  • 日向 進
    原稿種別: 本文
    1983 年 325 巻 p. 144-154
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    寛政2年から同3年にかけての普請記録である大工近江屋吉兵衛の『注文帳』を主な拠り所として, 天明大火直後の京都における町屋普請について考察した。その結果明らかになったのは次の諸点である。(i)大火後に普請された町屋の建築構成は, 規模や各部の高さなどの点において大火前との異同は認められない。しかし, 用材は一般的には松と杉とに限られ, 坪当り工費, 坪当り大工工数は平常時の水準値を下廻っており, いわゆる「仮家建て」として普請されていたところに, 大火直後の普請という特殊な建築事情がうかがえる。(ii)町屋普請の見積り・積算に際しては, 大工工数については「〜人掛」, 工費については「〜匁坪」という表記に示される標準化が成立しており, 一定の規模・質を有する町屋に対応する指標とされていた。(iii)このような生産技術の整備が町屋の量産の上で不可欠であり, そのような生産技術の前提となる建築的類型の成立する時期は享保年間頃と考えられる。
  • 保野 健治郎, 高井 広行, 難波 義郎, 遠木 律夫
    原稿種別: 本文
    1983 年 325 巻 p. 155-164
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
    In this paper, we consider of the finite difference graphical method for deciding the coefficient of the fire spread formula (logistic curve) concerning to general building fires. The results which were analyzed are showed bellow. (1) The finite difference graphical method was proved to be very useful as an approximation by computing real cases. (2) By the cases of K city and S city, the coefficients a and c of the fire spread formula was indicated to be the function of wind velocity v and area of building G. (3) The modification of the logistic curve is done by equation (4-2). The ratio of the quantity of modification n_1ε_0 to G become under 8 percent. (4) At spreading of fires to neighbouring houses, pitch of buildings, structure of buildings-surroundings, trees, etc. become the resistance to spread of fires. The value of r which defined by the resistant coefficient R(=G^r) in the equation (3-9) is changable according to city types or city characteristics. For example, in the case of K city or S city the value of r is nearly equal to 0.40 under the wind velocity v=2.5(m/sec). (5) The ratio β_j of A_H to A_K or A_S is shown equation (4-8). In the case of K city the ratio β_K is nearly equal to 6.9 from 1.3 and in the case of S city β_s is nearly equal to 5.7 from 3.6 under the conditions of v=0〜7(m/sec) and G=100〜600(m^2).
  • 原稿種別: 付録等
    1983 年 325 巻 p. App1-
    発行日: 1983/03/30
    公開日: 2017/08/22
    ジャーナル フリー
feedback
Top