Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
29 巻, 9 号
選択された号の論文の13件中1~13を表示しています
Original Papers
  • Atsushi NAKATA, Tomonori NOMOTO, Taro TOYOTA, Masanori FUJINAMI
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 865-869
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    Tip-enhanced Raman spectroscopy (TERS) of supported phospholipid bilayers in an aqueous environment is discussed in this paper. Two bilayer membranes were examined: 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC). We fabricated alumina- and silver-coated tungsten tips that are very robust in water. There was a large time-dependence in the TERS spectra for the DOPC bilayers, whereas no such time-dependence was observed in the DPPC bilayer spectra under the probe tip. The spectral changes of DOPC bilayers are discussed in terms of the fluidity of the liquid crystalline phase. Time-resolved TERS thus has the potential to characterize inhomogeneity and diffusion in fluidic phospholipid bilayer membranes.
  • Sharif HASAN, Jinhua DONG, Yuko HARA, Yoshihito MORIZANE, Futoshi SHIB ...
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 871-876
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    電子付録
    Open sandwich (OS) immunoassay utilizes antigen-dependent stabilization of an antibody variable region to quantify various antigens, enabling noncompetitive detection of small molecules with a broad working range. For further improvement of its sensitivity, OS Immuno-PCR was attempted with recombinant fusion proteins. The maltose binding protein-fused heavy chain variable region (MBP-VH) of an antibody that recognizes the C-terminal fragment of human osteocalcin (bone Gla protein, BGP), a biomarker for bone-related diseases, was immobilized onto microplate wells, and the antigen together with streptavidin (SA)-fused light chain variable region of the same antibody (SA-VL) was added and incubated. The amount of immobilized SA-VL was quantified by tethered biotinylated DNA, which was used to estimate the amount of antigen by realtime PCR. When BGP C-terminal peptide was detected, the limit of detection was 100 fg/mL, which was superior than that of our previously reported phage-based OS Immuno-PCR. The developed OS Immuno-PCR system will be useful for the detection of small molecule biomarkers for disease prevention.
  • Misato SAKAMOTO, Atsushi SHOJI, Masao SUGAWARA
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 877-883
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    電子付録
    A highly sensitive and rapid method for the determination of substance P (SP) and streptolysin O (SLO) in human serum is described. The assay is based on enriching the analyte by agglutination/precipitation of immuno-liposomes and enhancing the fluorescence intensity by gramicidin A channels. A mixture of the immuno-liposomes encapsulating a pH-sensitive fluorescence dye BCECF, gramicidin A and a given concentration of SP (or SLO) is preincubated in a solution and captured on anti-SP (or anti-SLO)-modified cover slips, followed by measuring fluorescence images after removing excess liposomes. The method allowed quantifying SP and SLO in the range from sub-pg mL−1 to pg mL−1, with detection limits of 0.32 pg mL−1 and 8 fg mL−1, respectively. The present method could determine SP and SLO in 50 – 125 times diluted human serum without any extraction steps. The assay can be completed within 60 min.
  • Wesley W. HSIAO, Hsien-Shun LIAO, Hsing-Hung LIN, Yueh-Lun LEE, Chia-K ...
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 885-892
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    Toxocarosis is a zoonosis caused by the transmission of the Toxocara canis (T. canis) larvae to humans. Its infectious third-stage larvae can invade the brains of paratenic hosts. The resultant brain damage can result in cerebral toxocarosis (CT). Astrocytes have important neurotrophic and neuroprotective functions in the brain. Substantial studies have shown that astrocyte apoptosis may contribute to the pathogenesis of many acute and chronic neurodegenerative disorders. We propose an alternation detection method, a combination of the astigmatic detection microscopy (ADM) and atomic force microscopy (AFM) techniques, to investigate the apoptosis of astrocytes triggered with T. canis larval excretory/secretory (Tc E/S) antigen. The variation in the pathology of a cell’s morphological changes was investigated with ADM and AFM analyses and then confirmed by western blotting. The results showed that the round cells increased as the concentration of Tc E/S antigen and incubated time increased. In addition, the mean height of apoptotic cells was approximately twice that of untreated normal cells, which meant there was correlation between the Tc E/S antigen treatment and cell height. For each cleaved caspase-3 in the cells cocultured with Tc E/S antigen and incubated for 9 h, the corresponding intensities increased about 34-fold (34.4 ± 1.8) compared with those of the control cells. This method can provide researchers with a perspective for understanding the limited information on the mechanism of astroglial injury and death during a T. canis larval invasion in a brain infection.
  • Adriana M. PIMENTA, M. Renata S. SOUTO, Rita I. L. CATARINO, M. Fernan ...
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 893-898
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    An automatic system was developed to determine ofloxacin in biological fluids and pharmaceutical formulations. Drug detection was carried out by a potentiometric membrane sensor based on [bis(trifluoromethyl)phenyl]borate as molecular-recognition material. The tubular shaped detector system was solidly attached to the manifold, creating a high-throughput stable setup (50 samples per hour) appropriate for routine antibiotic assessment. Under the optimized flow conditions, the sensor displayed a mean detection limit of 1 × 10−5 M, a linear response over the concentrations of 2 × 10−5 to 5 × 10−3 M (slope of 57.4 mV decade−1) and a wide working pH range (2.1 – 6.6). The procedure was successfully applied to ofloxacin analysis in pharmaceuticals (relative deviation lower than 6%) and biological fluids at levels usually found after drug administration of clinical doses (recoveries between 91 and 106%). No significant interference from common excipients found in commercial formulations and inorganic ions usually present in biological fluids was noticed.
  • Chun-Yan LI, Yu ZHOU, Yong-Fei LI, Chun-Xiang ZOU, Xue-Fei KONG
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 899-903
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    In this paper, we unveil a novel rhodamine compound-based fluorescent chemosensor (compound 1) for fluorescent detection of Hg2+ in an aqueous solution. The fluorescence enhancement of compound 1 was attributed to the formation of a complex between compound 1 and Hg2+ by 1:1 complex ration (K = 8.0 × 104), which has been utilized as the basis of fabrication of the Hg2+-sensitive chemosensor. A comparison of this method with some other fluorescence methods for the determination of Hg2+ indicated that this method has high selectivity and good water solubility. The analytical performance characteristics of the proposed Hg2+-sensitive chemosensor were investigated. The chemosensor can be applied to the quantification of Hg2+ with a linear range from 6.6 × 10−7 to 2.4 × 10−4 M and a detection limit of 1.3 × 10−7 M. The experiment results show that the response behavior of compound 1 towards Hg2+ is pH independent in neutral conditions (pH 5.0 – 9.0). Most importantly, the fluorescence changes of the chemosensor are remarkably specific for Hg2+ in the presence of other metal ions, which meet the selective requirements for practical application. Moreover, the response of the chemosensor toward Hg2+ is fast (response time less than 1 min). In addition, the chemosensor has been used for the determination of Hg2+ in river water samples with satisfactory results.
  • Tetsuo KUWABARA, Kosuke SUGIYAMA
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 905-909
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    A modified β-cyclodextrin (1) tethered with a phenylaminoazobenzen moiety has been synthesized for the purpose of developing a new guest-responsive color-change chemosensor. When the solution became acidic, 1 changed color from yellow to purple due to a structural change of the dye moiety from the azo form to the azonium one by protonation on the azo group. However, the pH titration curve of 1 was affected by the presence of the guest, as shown by the fact that the curve in the acidic region shifted to the neutral side by the presence of 1-adamantanol. This suggests that 1 has a potential to show a guest-induced absorption variation under the acidic condition. Upon guest addition at pH 0.61 at the concentration of 1 with 1 × 10−5 M, 1 showed a colorless-to-color change. Such hyperchromisity in the absorption spectrum of 1 is associated with a guest-induced conformational change of the dye moiety from inside to outside of the CD cavity, and is used for molecular sensing. Among various guests, 1 was found to be highly sensitive to a steroidal guest having a C12 hydroxyl group in the framework, such as ursodeoxycholic acid and lithocholic acid in an acidic aqueous solution.
  • Taro TOYOTA, Koyo UCHIYAMA, Takahiro KIMURA, Tomonori NOMOTO, Masanori ...
    原稿種別: Original Papers
    2013 年 29 巻 9 号 p. 911-917
    発行日: 2013/09/10
    公開日: 2013/09/10
    ジャーナル フリー
    We used a time-resolved interfacial tension measurement method with quasi-elastic laser scattering to investigate the effects of electrolytes and various surfactants on the nonlinear dynamics of the chemical oscillation that occurred at a water/nitrobenzene interface when a surfactant was added to the interface through a capillary. For both cationic and anionic surfactants, an electrolyte in the water phase was required for slow desorption of the surfactant from the interface. In the absence of an electrolyte, repulsion between the polar head groups of the ionic surfactants hindered adsorption of the surfactant molecules at the interface, resulting in their rapid desorption. In contrast, the presence of an electrolyte induced adsorption of the surfactant ions by screening their charged polar heads. Zwitterionic and nonionic surfactants were also examined and we deduced that the salting out effect of the surfactant produced by the presence of an electrolyte results in strongly attractive interactions between the surfactant molecules and the water/nitrobenzene interface.
Notes
Advancements in Instrumentation
Retraction
Announcements
feedback
Top