IEEJ Transactions on Power and Energy
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
Volume 146, Issue 9
Displaying 1-18 of 18 articles from this issue
Review
Paper
  • Sho Morishita, Tadashi Koshizuka
    2026Volume 146Issue 9 Pages 537-543
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    The renewable power plant projects must be constructed and start commercial operations quickly in order to increase the ratio of renewable power plants. On the other hand, suitable locations for onshore and offshore wind farms are far from the existing power grid. Therefore, these projects should adopt the underground cable transmission method to shorten the construction period. However, cable transmission systems face electrical problems caused by cable capacitance and issues related to reactive power control. In this paper, we investigate the solution for “Zero-Missing Phenomenon (ZMP)”—one of the associated issues—using an arc resistance model.

    Download PDF (1498K)
  • Atsushi Hayashida, Ryoichi Hara, Kazuki Kuran, Tatsuhito Nakajima
    2026Volume 146Issue 9 Pages 544-551
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    The concept of a regional microgrid (MG) is to evolve a part of the existing distribution system into an MG, together with regional renewable energy resources available close to the demand area. One of the difficulties of a regional MG is its expensive capital cost, especially paid for larger facility capacities required for rare emergency situations such as natural disasters. This paper introduces an MG model that utilizes the existing power distribution lines for daily power supply and electric vehicles (EVs) as virtual distribution lines during emergencies. By using EVs for emergencies, the investment cost would be saved. This paper proposes a coordinated control scheme for EVs, which have different capacities, and reused batteries for supply and demand balancing during an emergency and demonstrates how the proposed control scheme realizes the virtual distribution line function by EVs.

    Download PDF (1732K)
  • Daichi Watari, Nodoka Nakagaki, Shota Maeda, Kenta Okino
    2026Volume 146Issue 9 Pages 552-563
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    Aggregators in balancing markets operate Virtual Power Plants (VPPs) by integrating distributed energy resources like batteries, electric vehicles (EVs), and heat pump water heaters (HPs) installed in low-voltage households. A key challenge is managing user behavior uncertainty both in day-ahead bidding and real-time operation. This paper proposes a hierarchical planning framework using probabilistic scenario forecasting, two-stage stochastic programming, and model predictive control (MPC). Day-ahead bidding optimizes demand response (DR) capacity and resource schedules using two-stage stochastic programming under behavior uncertainty, while real-time MPC ensures commitment fulfillment. By explicitly linking scenario-based bidding with receding-horizon control, the framework increases bidding aggressiveness without compromising EV charging and hot-water availability. Evaluation with 30 households over 150 days shows the proposed method reduces net electricity cost by 14.1% and increases offered down-DR volume by 1.6 times compared to the robust method, while achieving a 98.69% DR fulfillment rate and limiting EV energy shortage and HP hot water shortage to 1.0% and 0.61%, respectively.

    Download PDF (2097K)
  • Ren Aoki, Hiroyuki Amano, Yoshihiko Kataoka, Seiji Fubo
    2026Volume 146Issue 9 Pages 564-573
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    As a method for maintaining power system stability, an M-G pair that combines a synchronous motor (M) and a synchronous generator (G) driven by renewable energy sources and battery storage has been proposed. This approach incorporates a battery control scheme that rapidly charges the batteries during transmission line faults (hereafter referred to as GTE (generator tripping emulation)). Similar to generator tripping, this scheme reduces the power flow on transmission lines and thereby contributes to transient stability. The GTE may induce significant torsional torque in the M-G pair due to rapid changes in active power. While torsional torque during high-speed reclosing failure is typically a concern for turbine generators, M-G pair can be subjected to both high-speed reclosing failure and GTE. Therefore, it is necessary to clarify the nature of the torsional torque induced in the M-G pair under both types of disturbances.

    In this study, the maximum torsional torque caused by high-speed reclosing failure and GTE was investigated using a shaft system model of M-G pair designed based on 100MVA unit. Numerical simulation results indicate that the maximum torsional torque induced under the combined disturbances is comparable to that experienced by a turbine generator during a high-speed reclosing failure.

    Download PDF (4493K)
  • Shunsuke Aida, Fumichika Yamaoka, Toru Amau
    2026Volume 146Issue 9 Pages 574-582
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    The increasing penetration of inverter-based resources (IBRs) raises concerns about the impact of reduced short-circuit capacity on transmission-line protection. In Japan, fault ride-through requirements are specified, but the fault-current characteristics of commercially deployed three-phase photovoltaic inverters have not been sufficiently clarified. This paper first evaluates the fault-current characteristics of seven three-phase photovoltaic inverters used in Japan through balanced-fault voltage-step tests. Measured instantaneous voltage and current signals are processed with a relay-based RMS algorithm to obtain voltage magnitude and active/reactive current components, thereby characterizing the magnitude and response speed of the supplied fault current. The results show clear differences among inverter types. The paper then analyzes, using a separate test configuration representing an IBR connected to a tapped branch of a transmission line, the effect of these characteristics on the apparent impedance seen by a grid-side distance relay. The resistance component of the apparent impedance generally becomes smaller than the true line impedance, whereas the reactance component can become either larger or smaller depending on inverter type, system short-circuit capacity, and inverter power factor. These findings indicate that distance-relay settings should take inverter-specific fault-current characteristics into account, with attention to both overreach and underreach.

    Download PDF (3098K)
  • Natsuki Matsukuma, Hibiki Natsume, Manabu Kodama
    2026Volume 146Issue 9 Pages 583-588
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    Proton exchange membrane (PEM) water electrolysis enables high-efficiency production of high-purity hydrogen. However, oxygen bubble retention within the anode-side porous transport layer (PTL) and flow channels decreases the electrochemically active area of the catalyst layer and thereby degrades performance. To clarify how anode flow-field design governs bubble removal from the PTL and channels, we conducted two-dimensional two-phase flow simulations based on the finite-volume method. The results show that an interdigitated flow field, in which baffles partition each channel into inlet and outlet segments to force liquid water into the PTL, generates a pronounced inlet-outlet pressure differential. This pressure differential enhances bubble expulsion downstream of the baffle and increases local water saturation near the catalyst layer. Moreover, longer baffles yield larger pressure differentials and higher water saturation. Regardless of baffle length or position, bubbles are discharged downstream of the baffle. Thus, placing the baffle closer to the outlet reduces the bubble-covered area of the catalyst layer and increases local water saturation.

    Download PDF (1035K)
  • Manato Goeku, Sora Hasegawa, Akihiro Tsusaka, Akinori Kato
    2026Volume 146Issue 9 Pages 589-594
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    The widespread deployment of photovoltaic systems (PVS) is progressing rapidly. However, as the scale of these systems increases, two major challenges have emerged: the elevated fire risk due to arc faults and the difficulty in locating such faults across large installations. Although conventional arc fault circuit interrupters (AFCIs) are capable of preventing fires by disconnecting the circuit, they do not provide fault location information. This necessitates time-consuming manual inspections and results in extended system downtime. This study proposes a novel method to address this issue. Based on experimental investigations into the noise characteristics of arc faults, we identified a specific high-frequency band in which the signal amplitude exhibits an attenuation with respect to the propagation distance from the fault origin. Utilizing this characteristic, we developed a localization technique employing an analog circuit, which includes a band-pass filter to extract the target frequency component and an amplifier to process its amplitude. The fault location is estimated from the resulting output voltage. The proposed method enables rapid and accurate localization of arc faults, thereby reducing maintenance time and costs, and contributing to improved safety and operational reliability of large-scale PVS installations.

    Download PDF (1632K)
  • Yota Sekiguchi, Yutaro Akimoto, Keiichi Okajima
    2026Volume 146Issue 9 Pages 595-602
    Published: September 01, 2026
    Released on J-STAGE: September 01, 2026
    JOURNAL RESTRICTED ACCESS

    As the adoption of renewable energy accelerates, utilizing surplus photovoltaic (PV) power for electric vehicle (EV) charging has attracted growing attention. However, EV user charging behavior involves significant uncertainties—such as driving distance and plug-in probability—that cannot be accurately captured by average-based models, leading to potential misestimation of PV surplus absorption. This study constructs a probabilistic framework that models EV charging behavior using data and Monte Carlo simulations, evaluating the PV surplus mitigation rate as a probability density function (PDF). Furthermore, it analyzes how variations in charging timing and user behavior affect the stability of PV absorption, and derives indicators such as the required number of EVs and their standard deviation. These insights contribute to the strategic design of realistic and scalable solutions for social implementation.

    Download PDF (1484K)
 
 