電気学会論文誌E(センサ・マイクロマシン部門誌)
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
132 巻, 1 号
選択された号の論文の9件中1~9を表示しています
論文
  • Satoshi Maruyama, Muneki Nakada, Makoto Mita, Takuya Takahashi, Hiroyu ...
    2012 年 132 巻 1 号 p. 1-9
    発行日: 2012/01/01
    公開日: 2012/01/01
    ジャーナル フリー
    An equivalent circuit model for the resonant-type vertical comb-driven optical MEMS (micro electro mechanical system) scanner has been developed based on the simple extension of the parallel-plate model. Both the electrostatic torque and the induction charge models are interpreted by using the equation-defined nonlinear dependent current source on the electrical circuit simulator platform. A systematic procedure has been investigated to fit the analytical model with the experimental results by using fitting parameters including the damping coefficient, the suspension width, and the comb gap. The developed simulation model has been used to verify a new control scheme to tune the scanner's oscillation amplitude in resonance by means of the pulse-width modulation of voltage at a given pulse height; the result indicates the effective use of digital electronics for the comb-driven optical scanner.
  • 蔭山 健介, 長島 秀明
    2012 年 132 巻 1 号 p. 10-15
    発行日: 2012/01/01
    公開日: 2012/01/01
    ジャーナル フリー
    Electret condenser microphones (ECM) with perfluoroalkoxy (PFA) film lamination (FilmECMs) were fabricated and the microgap layers were formed between laminated films in the gap of FilmECM to enhance the electric field in the gap and the resonance frequency. The average sensitivity from 1 to 10 kHz and the resonance frequency of a single degree of freedom system were measured for fabricated FilmECMs. The average sensitivity of the FilmECM was increased with the increase in the number of film lamination in the gap while the resonance frequency was decreased. Moreover, the average sensitivity of FilmECM improved further by the application of boron nitride (BN) agglomerates on films in the gap. As a results, one of the fabricated FilmECMs demonstrated −54.5 dB (0 dB = 1 V/Pa) for the average sensitivity. Furthermore the significant degradation of the sensitivity was not observed up to 50 kHz for any samples though the sensitivity rising, which might be caused by the diffraction from the edge of the test fixture, was observed at around 20 kHz. Hence, FilmECM should have a great potential for a wideband mircrophone or an ultrasonic sensor.
  • 辻 正敏
    2012 年 132 巻 1 号 p. 16-21
    発行日: 2012/01/01
    公開日: 2012/01/01
    ジャーナル フリー
    A method is proposed for detecting the lateral travel distance of a target via a simple system that is composed of sequential lobing in combination with two-frequency CW radar as well as a simple signal processing method that only uses four basic arithmetic operations. With this method the lateral travel speed is estimated by substituting [the measured angle error and the distance between the target and the sensor] for [the reciprocal of the angle error coherent to the system]. Experiments took place using an X-band sensor and the proposed method in order to measure the error involved. The results of the measurements were then used to propose a method of judging whether the detection rate of the target improved while also leading to a lower rate of false detections.
研究開発レター
部門記事
feedback
Top