International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
5 巻, 4 号
(October-December)
選択された号の論文の5件中1~5を表示しています
Review Papers
Original Papers
  • Stenly Tangkuman, Bo-Suk Yang, Seon-Jin Kim
    原稿種別: Original Paper
    2012 年 5 巻 4 号 p. 143-151
    発行日: 2012年
    公開日: 2012/10/04
    ジャーナル フリー
    Predicting the future condition of machine and assessing the remaining useful life are the center of prognostics. This paper contributes a new prognostic method based on grey model and survival probability. The first step of the method is building a normal condition model then determining the error indicator. In the second step, the survival probability value is obtained based on the error indicator. Finally, grey model coupled with one-step-ahead forecasting technique are employed in the last step. This work has developed a modified grey model in order to improve the accuracy of prediction. For evaluating the proposed method, real trending data of low methane compressor acquired from condition monitoring routine were employed.
  • Koichi Yonezawa, Daisuke Konishi, Kazuyoshi Miyagawa, François ...
    原稿種別: Original Paper
    2012 年 5 巻 4 号 p. 152-160
    発行日: 2012年
    公開日: 2012/10/23
    ジャーナル フリー
    Model tests and CFD were carried out to find out the cause of cavitation surge in hydraulic power plants. In experiments the cavitation surge was observed at flow rates higher and lower than the swirl free flow rate, both with and without a surge tank placed just upstream of the inlet volute. The surge frequency at smaller flow rate was much smaller than the swirl mode frequency caused by the whirl of vortex rope. An unsteady CFD was carried out with two boundary conditions: (1) the flow rate is fixed to be constant at the volute inlet, (2) the total pressure is kept constant at the volute inlet, corresponding to the experiments without/with the surge tank. The surge was observed with both boundary conditions at both higher and lower flow rates. Discussions as to the cause of the surge are made based on additional tests with an orifice at the diffuser exit, and with the diffuser replaced with a straight pipe.
  • Toru Shigemitsu, Junichiro Fukutomi, Hiroki Shimizu
    原稿種別: Original Paper
    2012 年 5 巻 4 号 p. 161-167
    発行日: 2012年
    公開日: 2012/11/17
    ジャーナル フリー
    Small-sized axial fans are used as air coolers for electric equipment. There is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of the efficiency and the increase of noise. Then, the adoption of contra-rotating rotors for small-sized fans is proposed for the improvement of the performance. In the case of contra-rotating rotors, blade row distance between the front and the rear rotors influences on the performance and the noise. Therefore, it is important to clarify the optimum blade row distance between front and rear rotors. The performance curves of the contra-rotating small-sized axial fan under the condition of different blade row distances are shown and the blade row interaction between the front and the rear rotors are discussed by the numerical results. Furthermore, the optimum blade row distance of the contra-rotating small-sized axial fan is considered.
  • Jin-Hyuk Kim, Kyung-Hun Cha, Kwang-Yong Kim, Choon-Man Jang
    原稿種別: Original Paper
    2012 年 5 巻 4 号 p. 168-173
    発行日: 2012年
    公開日: 2012/11/29
    ジャーナル フリー
    This paper presents a numerical investigation on the aerodynamic performance according to the application of splitter blades in an impeller of a centrifugal fan used for a refuse collection system. Numerical analysis of a centrifugal fan was carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model. A validation of numerical results was conducted by comparison with experimental data for the pressure and efficiency. From analyses of the internal flow field of the reference fan, the losses by the reverse-flows were observed in the region of the blade passage. In order to reduce these losses and enhance fan performance, two splitter blades were applied evenly between the main blades, and centrifugal impellers having the different numbers of the main blades were tested with their application. Throughout the numerical analyses of the centrifugal fan with splitter blades, it was found that the reverse-flow regions in the blade passage can be reduced by controlling the main blade numbers with splitter blades. The application of splitter blades in a centrifugal fan leads to significant improvement in the overall fan performance.
  • Jin-Hyuk Kim, Man-Woong Heo, Kyung-Hun Cha, Kwang-Yong Kim, Se-Wyan Ta ...
    原稿種別: Original Paper
    2012 年 5 巻 4 号 p. 174-179
    発行日: 2012年
    公開日: 2012/12/13
    ジャーナル フリー
    A numerical study to investigate the effect of intake vortex occurrence on the performance of an axial hydraulic turbine for generating tidal power energy in Sihwa-lake tidal power plant, Korea, is performed. Numerical analysis of the flow through an axial hydraulic turbine is carried out by solving three-dimensional Reynolds-averaged Navier-Stokes equations with the shear stress transport turbulence model. In the real turbine operation, the vortex flows are occurred in both the side corners around the intake of an axial hydraulic turbine due to the interaction between the inflow angle of water and intake structure. To analyze these vortex phenomena and to evaluate their impacts on the turbine performance, the internal flow fields of the axial hydraulic turbines with the different inflow angles are compared with their performances. As the results of numerical analysis, the vortex flows do not directly affect the turbine performance.
feedback
Top