Journal of Japan Association for Earthquake Engineering
Online ISSN : 1884-6246
ISSN-L : 1884-6246
Volume 18, Issue 1
Displaying 1-9 of 9 articles from this issue
Technical Papers
  • Ryo SASAKI, Takumi IMADA, Keisuke NODA, Kuniaki YAMAGISHI
    2018Volume 18Issue 1 Pages 1_1-1_17
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    The design load for structural design and for calculating the seismic force of building the live load of which is larger than the dead load, such as warehouses, is set depending on the engineering judgment of structural designers because there is no regulation regarding the seismic design load of such buildings in Japan. Although the seismic response reduction effect with load slipping, hereinafter referred to as the load slipping effect (slip effect), is not considered in typical structural design, consideration of this effect may contribute to a rational structural design. In the present study, in order to obtain the basic characteristics of the slip effect for an elasto-plastic frame, shaking table tests were carried out on a single-story elasto-plastic steel frame while varying the experimental parameters including the yield shear force of the frame. In order to incorporate the slip effect for various designs of general buildings, an analytical model with load slipping was constructed based on the results of static experiments. Based on the results of the shaking table tests and seismic response analyses, following results were found.

    1) The slip effect was increased with decreasing dynamic friction coefficient of the weight and increasing maximum velocity of input seismic motion.

    2) The slip effect was increased with increasing maximum slip displacement and cumulative displacement of weight.

    3) The response tendencies of the frame and weight of the analytical results for the parameters of interest generally agreed with the experimental results.

    Download PDF (3634K)
  • Isao KAMEI, Shiori MURASE, Mina SUGINO, Yasuhiro HAYASHI
    2018Volume 18Issue 1 Pages 1_18-1_34
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    A practical method of pulse characterization using a simple mathematical pulse model for near-fault pulse-like ground motions on the inland crustal earthquake is proposed. By using the proposed method, the pulse characterization and evaluation of the response of buildings for near-fault ground motions on the 2016 Kumamoto earthquake are presented and the validity of the using method is confirmed by comparing the time history and response spectrum of the pulse models with those of the observed records. Futhermore, the elastic story drift angle response characteristics of tall buildings subjected to the near-fault pulse-like ground motions are evaluated and indicate the higher mode excitation caused by multiple-pulses including longer and shorter period pulse.

    Download PDF (5068K)
  • - Determination Method of Tsunami Conditions Arriving at a Site with a Specific Scale -
    Naoto KIHARA, Tatsuto KIMURA, Hideki KAIDA, Keiichi IIZUKA, Naoki FUJI ...
    2018Volume 18Issue 1 Pages 1_35-1_58
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    A determination methodology of scenario tsunamis which are based on results of probabilistic tsunami hazard assessment and have specific annual frequencies of exceedance is proposed. By carrying out the probabilistic tsunami hazard deaggregation, tsunami conditions, which should be considered to determine the scenario tsunamis for fragility assessment in the tsunami PRA are identified. An annual frequency of exceedance of tsunami height in front of a seawall on a site by using the scenario tsunamis are evaluated and compared with that evaluated by the tsunami hazard analysis. The comparison shows good agreement, and thus the applicability of the proposed methodology is confirmed.

    Download PDF (1901K)
  • Masayuki YAMADA, Yoshiya ODA
    2018Volume 18Issue 1 Pages 1_59-1_76
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    This paper presents P-wave attenuation characteristics of 12 major active faults in Japan. We employed twofold spectral ratio method to estimate attenuation characteristics of active faults. A pair of seismic stations and fourteen earthquakes are selected for each active fault so that refuse the source spectrum, the path effect except focal zone and the site response. As the result, we achieved attenuation characteristics for 12 major active faults that are varied each other. The attenuation characteristics are not related with width of fracture zone of faults estimated from length of fault but good correlation with elapse ratios. These results suggest that the attenuation characteristics estimated from twofold spectral ratio method reflected with the stress accumulation processes of active faults.

    Download PDF (2467K)
  • Nobuyuki YAMADA, Hiroshi TAKENAKA
    2018Volume 18Issue 1 Pages 1_77-1_88
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    Sakishima Islands, southwestern Japan, have high earthquake risk since they have often been damaged by strong ground motion and tsunami, and there are high risks of the disaster in the future in these islands. Although the S-wave structure of these islands, important for ground motion estimation, has been modeled as J-SHIS model by Japanese government (Headquarters of Earthquake Research Promotion), it has not yet been validated because of lack of data. We conducted array observation of microtremor survey at 13 sites on the islands. We modelled one-dimensional S-wave velocity structure for each site with the inversion of estimated phase velocity. All the S-wave structures are successfully modeled with four velocity layers. Depth of the seismic bedrock, velocity layer over 3 km/s, differs with islands; it is 1.6 to 2.0 km at Miyako islands, whereas it is 0.2 to 0.5 km at Yaeyama islands. Based on these results, we showed the averaged Vs values of each layer and the depths of layer boundary at each site for construction of subsurface 3D model.

    Download PDF (3111K)
  • Go YAMAMOTO, Satoshi FUJITA, Hiroaki HARADA, Daiki NAKAMIZO, Keisuke M ...
    2018Volume 18Issue 1 Pages 1_89-1_103
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    Japan is one of the earthquake-prone countries, and has suffered from various earthquakes such as the Great East Japan Earthquake in 2011. Therefore, high seismic performance for buildings has been required, and seismic technologies have been actively studied in Japan. Seismic isolation system that isolates a superstructure from the ground is one of the effective earthquake-resistant technologies. The number of seismic isolated structure is overwhelmingly small compared with the ordinary earthquake-resistant structure, though it has increased after the Kobe Earthquake in 1995. Thus, in order to comprehend actual behavior of isolated structures during earthquakes and to improve seismic safety, it is important to obtain seismic records of the structures. Therefore this study dealt with seismic records of isolated structure that is a building of Tokyo Denki University and construction of an analytical model of the isolated structure based on the seismic records. The seismic record was started from December 2011. In this paper, relationships between the intensity of the seismic ground motion and the natural frequency of the building were investigated by using observed seismic records. In addition, an analytical model for seismic response analysis was constructed by considering the relationships. After that, reproducibility of the analytical model was evaluated by comparison between seismic records and analytical results by using the analytical model.

    Download PDF (3364K)
  • Yuma MORISAKI, Makoto FUJIU, Jyunichi TAKAYAMA, Kiyoko YANAGIHARA, Tat ...
    2018Volume 18Issue 1 Pages 1_104-1_121
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    In Japan, several big earthquakes are expected to occur in the near future. A lot of structural damages due to these earthquakes will cause enormous needs for evacuation of vulnerable people. However, there is a limit on the number of hospitals with efficiency and effective care during large scale earthquake disaster. Delay in efficiency and effective care by hospital care can disturb rapid care for vulnerable people of the damaged area. Considering these problems during large-scale earthquake disaster, this paper analyzed the capacity for vulnerable people during large scale earthquake disaster using KDB database. As a result of this analysis, beds of hospital for vulnerable people are not enough during large scale earthquake disaster.

    Download PDF (4293K)
  • Chika KAWAZOE, Ayaka YAMAMURA, Mina SUGINO, Hisatoshi KASHIWA, Yasuhir ...
    2018Volume 18Issue 1 Pages 1_122-1_133
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    Several buildings were seriously damaged due to fault rupture by the 1999 Kocaeli Earthquake, Turkey and the 1999 Chichi Earthquake, Taiwan. In preparation for future earthquakes accompanying fault rupture, it may be necessary to design buildings considering fault rupture, but the influence on the building foundation due to fault rupture is not clear. In this paper, we focused on pile foundation and conducted a model experiment in order to investigate the influence of fault rupture on the position of a pile and the deformation behavior. As a result, the fundamental behavior of deformation of the pile-soil system subjected the fault rapture was evaluated experimentally and it was clarified that the position of a pile where the fault rupture had influence on the pile depended on the type of the fault rupture because the different behaviors appeared in the soil depending of the type of the fault rupture.

    Download PDF (2934K)
Technical Reports
  • Meguru SAKAI, Toru TAKAHASHI, Yukiko NAKAMURA
    2018Volume 18Issue 1 Pages 1_134-1_149
    Published: 2018
    Released on J-STAGE: February 28, 2018
    JOURNAL FREE ACCESS

    Observation of strong ground motion and microtremor was carried out for six years on the building with very large side length ratio as 84 m in the ridge direction whereas the span direction is 9 m. Analysis using the Fourier transform was carried out focusing on the components of translational vibration and torsional vibration on the obtained record, and it was confirmed that the estimated natural frequency fluctuates according to the season. Furthermore, we investigated the phenomenon that the coherence decreases, and examined the details of the vibration properties. In addition, it was observed that the natural frequency varies even with a relatively short time change in temperature.

    Download PDF (14422K)
feedback
Top