Three kinds of standard life tests (rectangular power pulse (IEC), 1C constant current (GB/T-1) and rectangular current pulse discharge (GB/T-2)) were conducted at 45°C to evaluate the effects of the test profiles on battery degradation. A Lithium-ion cell for EV was used for the tests. Faster degradation was observed in the GB/T-2 test. In the comparison of cell voltage distribution during the three kinds of cycle evolution life tests, the ratio at high voltage in GB/T-2 was largest of the three standards. In addition, we clarified the cathode/anode reaction region slip which was accelerated by voltage mainly caused cell capacity fade from disassembly analyses results. These result suggested that the differences in the discharge profile of the cycle life tests affected the influence of the cathode/anode reaction region slip and the cathode degradation.