The gas holdup ε and the volumetric liquid-phase mass transfer coefficient
kLa were studied experimentally in a bubble column with a draught tube and with gas dispersion into the tube. From experimental observation ε increases with increasing gas velocity and frothing ability of liquid, while the other properties of the liquid and the column dimensions have a minor effect on ε.
kLa increases with gas velocity, column diameter, frothing ability of liquid and diffusivity of the dissolved gas, and decreases with increase in (
Di/
Do). Other dimensions of the column have a minor effect on
kLa. Based on these observations, empirical equations for ε and
kLa are proposed which are applicable to columns with diameters of 0.1-0.3 m.
At the same gas velocity,
kLa in this column is larger than that in the bubble column and smaller than that in the column with a draught tube and with gas dispersion into the annulus for a liquid with frothing ability.
抄録全体を表示