Journal of Japan Institute of Copper
Online ISSN : 2435-872X
Print ISSN : 1347-7234
Current issue
Displaying 1-50 of 64 articles from this issue
Papers
Microstructure
  • Yuma Nishimura, Yasuyuki Kaneno, Satoshi Semboshi
    2026Volume 65Issue 1 Pages 1-6
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    As the performance of electronic components has continued to advance, the development of copper alloys with both high strength and high electrical conductivity has become increasingly important. In this study, Cu-Co₃Ti alloys were investigated as a novel conductive material, with particular focus on their precipitation-hardening behavior during aging. Cu-Co-Ti alloys with various compositions were fabricated, and a pseudo-binary phase diagram of the Cu-Co₃Ti system was proposed based on DSC and electrical resistivity measurements. According to this diagram, the Cu matrix in Cu-Co₃Ti alloys can dissolve up to approximately 1.4 at.% of (Co+Ti) solute at temperatures above 900°C, and the precipitation of Co₃Ti within the Cu matrix is expected in Cu-1.0 at.% Co₃Ti alloy aged at 400−700°C. To verify this behavior experimentally, the Cu-1.0 at.% Co₃Ti alloy was subjected to solution treatment followed by aging. As a result, fine Co- and Ti-rich particles with approximately 10 nm in diameter were uniformly precipitated throughout the Cu matrix, together with a small number of rod-shaped CoTi particles (approximately 500 nm). Contributing to this microstructural evolution, the aged alloy exhibited an increase in Vickers hardness of up to 25 HV compared with the solution-treated alloy, while its electrical conductivity improved by 15% IACS.

    Download PDF (1930K)
  • Hiroo Mikami, Katsunari Oikawa, Nobufumi Ueshima, Minoru Itou, Masaki ...
    2026Volume 65Issue 1 Pages 7-12
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Recent trends in electronic component miniaturization demand copper alloys with high strength, conductivity, and formability. Although strengthening generally compromises bend formability, precipitation–hardened Cu–Ni–P alloys offer a promising balance of these properties. Optimizing this balance is crucial for further component miniaturization; however, the relation between processing conditions and precipitation behavior remains unclear. The purpose of this study is to clarify the effects of precipitation heat treatment on the mechanical properties, conductivity, and microstructure of a Cu–0.9Ni–0.1P–0.15Zn–0.03Sn (mass%) alloy.

    Plates of Cu–0.9Ni–0.1P–0.15Zn–0.03Sn (mass%) (0.3–mm–thick) were prepared by hot rolling, precipitation treatment, cold rolling and annealing. The precipitation treatment was carried out at 400, 450, or 500°C for 3, 6, 12, or 168 h. Untreated samples were also prepared. Specimens were subjected to 90° bending tests in the rolling and transverse directions, and cracks were examined by optical microscopy. Conductivity and mechanical properties were measured via the eddy current method and Vickers hardness and tensile tests, respectively. Microstructures were characterized using SEM–EBSD and TEM.

    In the bending tests, no cracks were observed under any conditions, indicating the material is practically formable. This suggests that the influence of precipitation heat treatment on bend formability is negligible. While no time dependence was observed up to 12 h, conductivity increased at 168 h. Conductivity also exhibited temperature dependence, increasing with higher temperatures. The time dependence is attributed to differences in the precipitation phase transformation process, while the temperature dependence is likely due to varying transformation rates. Vickers hardness peaked at intermediate times, and tensile strength showed a similar trend. This is attributed to the balance between solid solution strengthening and precipitation hardening.

    Download PDF (1704K)
  • Hiromi Miura, Soushi Tanaka, Chihiro Watanabe
    2026Volume 65Issue 1 Pages 13-20
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Drastic enhancement of various properties of Cu–Ni–Si alloy was aimed by means of evolution of heterogeneous nano–(HN–)structure and additions of trace amounts of P and Sn, where these elements had property of easily segregation at grain boundaries. Simple 90% cold rolling developed a typical HN–structure with dispersed “eye”–shaped twin domains in all the specimens, regardless element addition. Evolution of HN–structure notably increased ultimate tensile strength (UTS). Even while the evolved HN–structures looked similar, UTS of the alloy with additions was approximately 50 MPa or further higher than that without the addition. This difference was almost unchanged even after aging;UTS of with additions increased from 697MPa/R.D. and 785 MPa/T.D. to 902MPa/R.D. and 984MPa/T.D. respectively, and those without addition were from 641 MPa/R.D. and 750 MPa/T.D. to 843 MPa/R.D. and 920 MPa/T.D. Two step aging of with additions further increased UTS up to 1.0GPa/T.D. and 891MPa/R.D. with having other superior properties of ductility of 10.6%/T.D. and electrical conductivity of 54.4%IACS. The achieved excellent balance of properties was attributed to the complex grain–boundary segregation (GBS) of P and Sn forming atom pairs. That is, GBS enhanced purification of Cu based matrix, and developed strain field which significantly impeded dislocation motion across or around grain boundaries.

    Download PDF (2455K)
  • Hayato Yokoyama, Wanlalak Sanphiboon, Seungwon Lee, Taiki Tsuchiya, Yo ...
    2026Volume 65Issue 1 Pages 21-25
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The longitudinal morphology of Nb/Nb₃Sn filaments in bronze–processed superconducting wires was investigated. Since Nb₃Sn is formed via an interfacial reaction between the Nb and the Cu–Sn alloy matrix, characterizing this interface is one of factors in understanding the Nb₃Sn growth process. Filaments were extracted by chemical etching of the Cu–Sn matrix, enabling direct observation along the wire axis. SEM observations showed that most filaments were aligned parallel to the extrusion direction, and their widths were consistent with the Nb₃Sn core diameters observed in cross sections. EDS analysis revealed Nb and Sn with an Nb:Sn ratio close to stoichiometric Nb₃Sn. Correlative SEM and TEM observations indicated that the surface roughness originated from the undulated Cu–Sn/Nb₃Sn interface, while FE–SEM imaging confirmed that the roughness consisted of fine Nb₃Sn grains. These results demonstrate that chemical etching is an effective method for evaluating the intrinsic filament morphology of Nb₃Sn superconducting wires.

    Download PDF (2217K)
  • Ryuichi Arai, Go Odachi, Kazue Nishimoto, Tsutomu Koizumi, Goro Miyamo ...
    2026Volume 65Issue 1 Pages 26-31
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    As semiconductor devices continue to be miniaturized, the components used in inspection equipment, such as contact probes, are also required to become smaller. This trend increases the demand for the copper–based conductive materials used in these probes to exhibit higher levels of strength, electrical conductivity, hardness, and fatigue resistance. According to previous research, Cu–Ag two–phase alloy wires produced by heat treatment and drawing processing are known as materials with an excellent balance of strength and electrical conductivity. In this study, we aimed to further enhance the strength of Cu–Ag dual–phase alloy fine wires by utilizing the low-temperature anneal hardening phenomenon. When the Cu–10 wt.%Ag dual–phase alloy fine wires were subjected to annealing at 200°C, the Vickers hardness increased by up to 25 HV, and the electrical conductivity also improved by 3%IACS. These findings indicate that low–temperature annealing is effective for simultaneously improving the conductivity and strength of Cu–Ag dual–phase alloy drawn wires. Additionally, we observed several key microstructural changes during the low–temperature annealing process, including strain relaxation (a decrease in dislocation density), the formation of annealing twins, and morphological evolution of the Ag phase. These microstructural changes are considered to contribute to the low–temperature anneal hardening in the Cu–Ag dual–phase alloy wires.

    Download PDF (2405K)
  • Nanami Onomichi, Masataka Yamamoto, Mitsuharu Todai
    2026Volume 65Issue 1 Pages 32-37
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Cu-Ti alloys exhibit high strength along with excellent bendability and stress-relaxation resistance;however, their electrical conductivity is significantly lower than that of Cu-Be alloys. Therefore, further improvement in both the electrical conductivity and strength of Cu-Ti alloys is required. The addition of a third element is a promising approach to improving the electrical conductivity and strength of Cu-Ti alloys. Although many studies have focused on Cu-Ti alloys containing 3-5 at.% Ti, research on low-concentration Cu-Ti alloys has been very limited. In this study, the effect of Ni addition on the electrical conductivity and strength of a low-concentration Cu-Ti alloy (Cu-1 at.% Ti) was systematically investigated. For all compositions of Cu-1Ti-xNi (at.%, x=1, 2, 3), CuNiTi (tetragonal) precipitates formed during solution treatment or aging treatment. In the Cu-1Ti-1Ni and Cu-1Ti-2Ni alloys, fine β’-Cu₄Ti precipitates were observed within the grains. In contrast, β’-Cu₄Ti precipitation was not detected in the Cu-1Ti-3Ni alloy;instead, Ni₃Ti precipitates formed along the grain boundaries. These precipitates contributed to improvements in both electrical conductivity and strength. Furthermore, because the transformation to β-Cu₄Ti did not occur in any of the alloys, no decrease in hardness was observed.

    Download PDF (2676K)
  • Yuito Maeda, Yui Yasukawa, Norimitsu Koga, Chihiro Watanabe, Hiromi Mi ...
    2026Volume 65Issue 1 Pages 38-44
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The hot–extruded bars of a Cu–Zn system alloy were subjected to groove rolling up to area reduction of 57% at maximum. With increasing rolling reduction, the initial coarse–equiaxed grains were macroscopically elongated parallel to the rolling direction. Dense mechanical twinning, which instantly subdivided the coarse initial grains, developed a hierarchical heterogeneous nanostructure mainly composed of twins with inter–spacings of 100–300 nm. Nanoindentation measurements revealed that the hardness difference between the grains with and without twins became larger with increasing rolling reduction. The difference in the average hardness, therefore, became more pronounced as the area reduction increased. The tensile strength of the as–hot–extruded bar was 464 MPa, which increased more rapidly with increasing reduction to 704 MPa and 817 MPa after 42% and 57% reductions, respectively. Loading–unloading–reloading tests were conducted to evaluate hetero–deformation–induced (HDI) stress associated with the mechanical heterogeneity between the grains with and without twins. The HDI stress was 412 MPa at 42% area reduction and further increased up to 537 MPa at 57% reduction. These results demonstrate that the remarkable increase in strength achieved by groove rolling is caused not only by significant grain refinement induced by the dense mechanical twins, but also by substantial HDI strengthening arising from the heterogeneous deformation of the hierarchical heterogeneous nanostructure.

    Download PDF (2046K)
  • Dasom Kim, Naoki Takata, Yuhki Tsukada, Junji Umeda, Toshihiko Shimizu ...
    2026Volume 65Issue 1 Pages 45-49
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    This study reports unique temperature-dependent tensile behavior in a laser powder bed fusion (L-PBF) processed Cu-Cr-Zr alloy. The alloy’s strength initially decreases to approximately 220 MPa as the temperature increases, then increases above 350 MPa at 500°C, and then decreases to 250 MPa at 600°C. The microstructure consists of elongated Cu grains with a high Cr solute concentration (〜1 mass%), resulting from rapid solidification during L-PBF. Transmission electron microscopy of specimens deformed at 500°C revealed numerous nanoscale Cr-rich precipitates embedded in the supersaturated Cu matrix. Nanoscale precipitates can act as barriers to dislocation motion, thereby increasing internal stress during plastic deformation at elevated temperatures. The results provided insights into the temperature-dependent tensile behavior of Cu alloys, which is regulated by non-equilibrium microstructures formed in the L-PBF process.

    Download PDF (5390K)
  • Hiroshi Yorifuji, Itoha Hanamure, Wanqing Jiang, Koji Watanabe, Satosh ...
    2026Volume 65Issue 1 Pages 50-56
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Cu–Ni–Si alloys (Corson alloys) provide an excellent balance of strength and electrical conductivity, making them widely used as connector materials. For press forming of connector terminals, the material must also exhibit bendability and press punching behavior to ensure precise shape formation and productivity (extended die life). In this study, Cu–Ni–Si alloys with trace additions of S and Mn were fabricated, and the effects of co–adding S and Mn on the alloy microstructure, strength, bendability, machinability, and press punching performance were investigated. The Cu–Ni–Si–S–Mn alloy, containing 0.01 wt.% S and 0.02 wt.% Mn, was found to retain equivalent strength, electrical conductivity, bending fatigue properties, and bendability to conventional Cu–Ni–Si alloys while achieving superior press punching performance. MnS and Cu2S inclusions act as fracture initiation sites during press processing and contribute to a reduction in the shear plane ratio. On the other hand, a high S content significantly degrades fatigue properties and worsens bendability.

    Download PDF (2352K)
  • Michiaki Yamasaki, Itsuki Tateoka, Takaaki Toyoda, Soya Nishimoto, Tsu ...
    2026Volume 65Issue 1 Pages 57-63
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    To elucidate the crystal orientations that cause shear band formation during Good Way and Bad Way bending of rolled Cu–Ni–Co–Si alloys, the susceptibility of the texture formed in actual rolled sheets to shear band formation was determined by calculating the Taylor factors Mpl for the plane strain compression mode and Msh for the shear strain mode, respectively. When Msh is lower than Mp, shear bands might develop during the bending deformation. We proposed an index of the probability of shear band formation, called Mdiv, calculated by dividing Mpl by Msh. In addition, we obtained a cumulative maximum Mdiv map by linking the Mdiv with positional information. This map provides useful information, such as the optimal arrangement of textured grains, for the design of rolled copper sheets that exhibit ductility during bending.

    Download PDF (6413K)
  • Toru Nishimura, Hirotaka Matsunoshita, Kenichiro Suehiro
    2026Volume 65Issue 1 Pages 64-68
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    This study investigated the effects of microstructure and edge surface condition on the edgewise bending workability of copper plates.

    In the experiment on microstructure, oxygen–free copper (C10200) was heat–treated to produce five different grain sizes, then rolled to a thickness of 1.0 mm and cut to a width of 20 mm. Edgewise bending tests were conducted under the condition of R/W=1 with a 90° bend, using samples with smooth, burr–free edge surfaces. For specimens with coarse grains (approximately 46–65 μm), those with larger average grain sizes fractured at smaller bending angles. In contrast, specimens with fine grains (approximately 8–18 μm) could be bent edgewise to 90°, and the sample with the smallest average grain size showed no local necking, confirming excellent bending workability. These results suggest that smaller grain sizes distribute stress more evenly and suppress local fracture. This finding is consistent with knowledge obtained from flatwise bending.

    Additionally, to clarify the influence of edge surface condition, five types of specimens were prepared from commercial C10200–1/2H using different processing methods, and edgewise bending tests were conducted at 90°. Specimens with burrs on the edge showed stress concentration at the burr recesses, resulting in large shear bands and many microcracks, which caused early fracture even with slight bending. In contrast, specimens without burrs before processing or with burrs removed from the edge showed only fine shear bands distributed along the outer edge, resulting in stable bending behavior.

    These results show that, as with flatwise bending, refining the grain size to promote stress distribution is effective for improving the edgewise bending workability of copper plates, and that, unlike flatwise bending, strict edge quality control to eliminate defect initiation points such as burrs on the edge is also important.

    Download PDF (2369K)
  • Yuga Okamoto, Yuichiro Hayasaka, Kaichi Saito
    2026Volume 65Issue 1 Pages 69-74
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Elucidating discontinuous precipitation (DP) mechanism is crucial for the development of high-performance Cu-Ti alloys like Cu-4 at.% Ti. In this study, the isothermal aging behaviors of three Cu-Ti alloys, including two where Zr was partially substituted for Ti, were investigated in a comparative study. The supersaturated solid-solution alloys with or without the Zr dopant, under the test temperature of 450°C, initially showed similar age-hardening behaviors with their peaks located at about 10-hour duration, and after that the Zr-doped alloys exhibited reduced age-softening behaviors. Unlike the binary Cu-4Ti (at.%), the ternary Cu-3.9Ti-0.1Zr alloy particularly had no DP nucleated or grown for up to a 100-hour duration and retained high levels of the mechanical properties such as tensile strength and fracture elongation comparable to those recorded at 10 h. Atomic-scale scanning transmission electron microscopy imaging combined with energy-dispersive X-ray spectroscopy analysis revealed that the ternary alloy had its grain boundaries decorated by the preferentially segregated Zr solutes, leading to an amorphous local atomic structure. The possible effects of the Zr-doping on the microstructure evolution of the Cu-Ti alloy were described, and the local structural environment within and in between the matrix grains that may result in suppressing the discontinuous precipitation is discussed.

    Download PDF (6528K)
  • Ikuo Ohnuma, Takao Suzuki, Masanori Enoki, Hiroshi Ohtani
    2026Volume 65Issue 1 Pages 75-80
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    A thermodynamic evaluation of the Cu–Ti phase diagram was carried out, considering the metastable miscibility gap in the FCC (αCu) phase. A new Gibbs energy model for the intermetallic compound (IMC) phases was proposed and applied to the phase diagram calculation. Based on the evaluated phase diagram, the microstructural evolution of a Cu–Ti alloy undergoing an aging heat treatment was investigated thermodynamically. It was suggested that spinodal decomposition occurs in the early stage of aging, followed by ‘continuous precipitation’ (CP) via the nucleation and growth of the Cu3Ti2 phase from decomposed Ti–richer FCC domains. Once CP has been completed, ‘Ti segregation’ at the grain boundary (GB) is predicted by a tangent line parallel to the common tangent for the (αCu)+Cu3Ti2 equilibrium. Subsequently, cooperative growth of the (αCu) and β–Cu4Ti stable phases arises from the Ti–segregated GB, which has a large driving energy for ‘discontinuous precipitation’ (DP). These microstructural evolutions are almost consistent with the experimental study reported by Semboshi et al.

    Download PDF (2686K)
  • Taehyun Kim, Pramote Thirathipviwat, Makoto Hasegawa
    2026Volume 65Issue 1 Pages 81-86
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    This study investigates texture evolution in single α–phase Cu-30wt% Zn alloy to clarify the influence of twinning on texture development during high temperature uniaxial compression. The compression tests were conducted at temperatures from 873 K to 1073 K under true strain rates from 1×10−2 s−1 to 5×10−4 s−1 up to the true strain of −1.0. The deformation conditions were represented by the logarithmic Zener–Hollomon parameter (ln Z) as a function of temperature and true strain rate. The texture analysis showed that the main texture component developed near the {101} orientation under high ln Z deformation conditions (lower temperature and higher strain rate) and changed to {001} orientation with decreasing ln Z through preferential dynamic grain growth (PDGG). However, with further decrease in ln Z, the main texture component did not show specific orientation. A decrease in ln Z generally increases the volume fraction of {001} orientation;however, the volume fraction decreases at very low ln Z conditions. The weakening of {001} fiber texture is attributed to repeated twinning occurring more than three times within a twin–merged grain. These results suggest that high frequency of twinning may contribute to orientation randomization and hinder development of the {001} fiber texture, leading to texture weakening under the lowest ln Z condition.

    Download PDF (3393K)
Mechanical Properties
  • Shunsuke Shirae, Ryusei Kato, Norimitsu Koga, Chihiro Watanabe
    2026Volume 65Issue 1 Pages 87-92
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Copper (Cu)/martensitic steel multilayered sheets exhibit an excellent strength–conductivity balance superior to that of conventional Cu alloys. The strength–conductivity balance exceeds 50000 MPa·%IACS, surpassing that of conventional Cu alloys. However, their practical application is limited by poor bendability due to the low ductility of the hard martensitic layers. In this study, a “quenching after working (QAW)” process is proposed to overcome this problem. In this process, bending is performed in soft Cu/carbon steel multilayered sheets, followed by quenching to transform the carbon steel layers into “hard” martensite. First, bendability of Cu/carbon steel multilayered sheets was evaluated using a W–bending test. Bending to approximately 90° was achieved regardless of the Cu volume fraction., and no significant anisotropy in bendability was observed. Wrinkles were observed in the outermost Cu layer under severe bending conditions. In extremely severe conditions, small cracks were formed in the outermost carbon steel layer; however, these cracks were arrested at the Cu/carbon steel interfacial boundary, indicating that the Cu layers suppress the crack propagation. Furthermore, the shape change of W–bent sheets after quenching was evaluated, and the dimensional change was negligibly small, within a few tens of micrometers. These results demonstrate that the QAW process effectively overcomes the bendability limitations of the Cu/martensitic steel multilayered sheets and enables the fabrication of high–strength and high–conductivity components with complex shapes.

    Download PDF (1881K)
  • Nobufumi Ueshima, Masashi Yamatoya, Katsunari Oikawa
    2026Volume 65Issue 1 Pages 93-98
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The creep behavior of pre–tensile strained alpha brass was investigated. The primary creep strain was increased by tensile pre–strain while secondary creep rate was little affected. Based on the stress exponent of 6.32 and the activation energy of 70.2 kJ/mol─obtained from the temperature and stress dependence of the secondary creep rate in the as–received specimen─the dominant creep mechanism was identified as either pipe diffusion–limited dislocation creep or dislocation glide hindered by forest dislocations. By combining the one–variable internal state variable model with creep model and also with back stress, it is suggested that –150 MPa of back stress can explain the increase of primary creep and similarity of secondary creep rate. The calculated results indicate that the back stress introduced by tensile pre–strain increases effective stress and thus creep strain rate in primary region. On the other hand, back stress becomes less significant in secondary region due to creep deformation.

    Download PDF (1174K)
  • Keisuke Yarimizu, Hiroshi Hyodo, Ryosuke Miyahara, Tomotsugu Aoyama, K ...
    2026Volume 65Issue 1 Pages 99-105
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In recent years, the demand for automotive connectors to reduce weight and size has progressively increased in order to achieve higher packaging density. Consequently, the performance requirements for materials and surface treatments have become more stringent. Copper alloy materials used for small female terminals must exhibit a well–balanced combination of high yield strength, excellent stress relaxation resistance, and superior bendability. Cu–Ni–Si–Sn–Zn alloys have been identified as promising candidates. When designing spring portions for small female terminals, the Bauschinger effect must be considered. However, systematic investigations on the Bauschinger effect during bending deformation of Cu–Ni–Si–Sn–Zn alloys are limited. In this study, Cu–Ni–Si–Sn–Zn alloy specimens with various preferred orientations were prepared, and the relationship between texture and the Bauschinger effect was experimentally evaluated. Regarding TD bending, with a bending axis parallel to the rolling direction, the {420}–oriented specimen exhibits the highest Bauschinger ratio. EBSD analysis revealed that specimens with higher mean Schmid factors exhibit higher Bauschinger ratios, indicating a smaller Bauschinger effect. These results confirm that the Bauschinger effect in the bending of Cu–Ni–Si–Sn–Zn alloys is affected by Schmid factors of active slip systems.

    Download PDF (6944K)
  • Shintaro Yoshie, Kengo Yoshida
    2026Volume 65Issue 1 Pages 106-111
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The increasing electrification of automobiles has intensified the demand for highly reliable electronic connectors, making accurate prediction of stress relaxation in copper alloy connector components increasingly important. In this study, the primary creep behavior of C1020P–1/2H and its annealed counterpart was experimentally investigated. The results showed that the strain rate in the primary creep regime decreased with time. Although the creep strain rate increased markedly with increasing applied stress, the applied stress had little influence on the accumulated primary creep strain. The experimental observations were qualitatively interpreted based on the concept that mobile dislocations capable of moving under stresses below the yield stress gradually decrease during deformation. On this basis, a power–law creep model was developed by introducing an internal variable that effectively reduces the deformation resistance. The proposed model successfully reproduced the decrease in strain rate during primary creep. Because the model is formulated within a rate–dependent elasto–viscoplastic constitutive framework, it is capable of continuously simulating pre–straining, unloading, and creep.

    Download PDF (999K)
  • Tetsuya Ando, Toko Tokunaga, Shunsuke Araki, Shoya Kato, Ryo Nishimura ...
    2026Volume 65Issue 1 Pages 112-117
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    We investigated tensile properties of Cu–Ni–P alloys with different Ni/P concentration ratio (Ni/P=1.1, 1.8 and 2.6) to clarify the effect of Ni/P concentration ratio on mechanical properties of Cu–Ni–P alloy. The investigation of aging properties showed that the difference between each alloy was smallest and the absolute value was highest after aging at 723 K for 7.2 ks. Furthermore, the TEM microstructure observation suggested that all alloys were precipitation strengthened by the estimated Ni12P5 precipitates. And there was no significant difference in tensile strength, 0.2% proof stress, and elongation due to differences in Ni/P concentration ratio and tensile test temperature. Therefore, it can be concluded that all the alloys are available for heat exchanger tube within the given composition range. The specimen with Ni/P=1.8 showed a well–developed {100} texture in the plane perpendicular to the extrusion direction. In contrast, the specimen with Ni/P=2.6 and 1.1 showed a well–developed {100} and {111} texture, respectively.

    Download PDF (3146K)
  • Yuhan Liu, Ryusei Hakuzan, Yusaku Seimiya, Shumpei Ozawa
    2026Volume 65Issue 1 Pages 118-123
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The surface tension of liquid copper was measured over a wide temperature range (1500-2100 K) under controlled oxygen partial pressures (PO2) using an electromagnetic levitation technique. Although PO2 was controlled via H2-CO2 gas equilibria, thermodynamic equilibrium between the imposed PO2 and the dissolved oxygen concentration ([O]) could not be confirmed under the present experimental conditions. The surface tension was analyzed based on the oxygen mole fraction (xO) calculated from the measured oxygen concentration in quenched samples. A consistent correlation between surface tension and xO was observed over the investigated temperature range, in good agreement with previous studies. An apparent adsorption equilibrium constant Kad was evaluated using the Szyszkowski equation, and its temperature dependence followed a van’t Hoff-type relation, from which the corresponding apparent enthalpy and entropy changes were derived. Furthermore, the surface tension was described as a function of temperature and oxygen mole fraction based on the present analysis, and the calculated values reproduced the experimental data well. These results demonstrate that oxygen concentration-based parameters provide a rational and practical framework for describing the effect of oxygen on the surface tension of liquid copper.

    Download PDF (1323K)
Corrosion, Protection
  • Rihoko Aoyama, Misato Matsumoto, Fuka Takahashi, Taiga Ozaki, Yutaka Y ...
    2026Volume 65Issue 1 Pages 124-128
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Water leakage in copper air conditioning tubes was attributed to carbon film–dependent pitting corrosion arising from the interaction between residual carbon film on the inner tube surface and water quality. To inhibit this pitting corrosion, 1–hydroxyethane–1,1–diphosphonic acid (HEDP), used as a scale dispersant, and benzotriazole (BTA), used as a copper corrosion inhibitor, are commonly added as water treatment chemicals and were reported to provide corrosion prevention effects. In addition, Anion Exchanged Water is one technology used to suppress corrosion. This is produced by replacing corrosion–promoting ions such as chloride ions and sulfate ions contained in tap water with corrosion–inhibiting ions such as bicarbonate ions using anion exchange resin. In a previous study, we reported that Anion Exchanged Water inhibited corrosion in the presence of HEDP and BTA. In this study, we investigated the effect of BTA concentration on the corrosion resistance of copper in Anion Exchanged Water in the presence of water treatment chemicals. We performed natural electrode potential measurements and polarization curve measurements using test water in which BTA was adjusted to concentrations of 1, 3, and 5 mg L–1. Furthermore, we used copper plates and copper tubes with varying amounts of residual carbon film as test specimens to investigate the effect of the carbon film on corrosion resistance. Corrosion potential measurements showed that the potential increased with increasing BTA concentration, independent of the amount of residual carbon film. Anodic polarization curves showed that the current density decreased with increasing BTA concentration, independent of the amount of residual carbon film. Taken together, these findings indicated that, in Anion Exchanged Water, the corrosion inhibition effect of BTA increases with concentration regardless of the amount of residual carbon film.

    Download PDF (1111K)
  • Taiga Ozaki, Fuka Takahashi, Rihoko Aoyama, Yutaka Yamada, Osamu Sakur ...
    2026Volume 65Issue 1 Pages 129-133
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In the construction industry, an increasing number of facilities are adopting building equipment that utilizes abundant groundwater. These facilities often employ multi-circulation hot water supply systems and air conditioning systems. Due to their excellent thermal conductivity, workability, and corrosion resistance in freshwater, copper tubes are widely used as heat transfer tubes in the heat exchangers of these systems. However, copper tubes are susceptible to corrosion depending on the operating environment and material characteristics. In groundwater environments, it has been reported that Type I pitting corrosion, erosion corrosion, and grooving corrosion at brazed joints frequently occur. To mitigate the corrosion of copper tubes, this study investigated the applicability of high-strength Cu-Sn-P alloys through dissolution tests and electrochemical measurements. In the dissolution tests, the amount of copper dissolved from the alloy tubes decreased over time, and Sn was detected on the tube surfaces. Polarization curve measurements revealed that at pH 6, only the alloy tube exhibited an anodic peak, indicating a suppression of anodic current density compared to the copper tube. Furthermore, at pH 6.5 and 7.0, both the onset and peak potentials of the alloy tube shifted to more noble values than those of the copper tube, confirming the suppression of anodic reactions. These results suggest the formation of a Sn-containing composite film on the alloy surface, which is expected to provide superior corrosion resistance compared to conventional copper tubes.

    Download PDF (2852K)
  • Fuka Takahashi, Misato Matsumoto, Taichi Matsumoto, Yutaka Yamada, Sat ...
    2026Volume 65Issue 1 Pages 134-138
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Leakage due to carbon film–dependent pitting corrosion in copper tubes used for heat transfer in building air conditioning systems has become a significant problem. Previously, we reported a simple and versatile filling test method for quantifying residual carbon as well as a technique for evaluating pitting. In these studies, we assessed pitting corrosion in copper tubes by filling them with a mixed solution containing hydrogen peroxide, chloride, and sulfate ions as corrosion accelerators and the corrosion inhibitor benzotriazole (BTA). The tubes were filled with test solutions for evaluating pitting susceptibility and the number of corrosion products and residual carbon content were assessed. Furthermore, we propose a new method for residual carbon quantification based on potential difference. This method involves measurement of the spontaneous electrode potential of copper tubes in a degassed solution primarily composed of 1–hydroxyethane–1,1–diphosphonic acid (HEDP) and BTA. In this study, both methods were used to evaluate the residual carbon content and pitting behavior of 11 types of copper tubes used in actual equipment. While the residual carbon content measured by the filling test method was around 5 mg m−2 for most copper tubes, the potential difference method identified many samples with a residual carbon content exceeding 20 mg m−2. The residual carbon content measured in the samples was inconsistent between the two measurement methods. This was due to the inherent differences in the characteristics of the two testing methods.

    Download PDF (1490K)
  • Tomoya Takenaka, Misato Matsumoto, Fuka Takahashi, Taichi Matsumoto, Y ...
    2026Volume 65Issue 1 Pages 139-143
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Pitting corrosion in copper tubes used in air conditioning systems triggered by the presence of carbon film on the inner surface and specific water chemistry can lead to critical water leakage. This pitting corrosion can be suppressed by the addition of inhibitors to water used in treatment including phosphonic acid (HEDP) as a scale dispersant and benzotriazole (BTA) as a copper rust inhibitor. In the presence of HEDP and BTA, silicate ions (SiO44−), calcium ions (Ca2+), and bicarbonate ions (HCO3−) have also been shown to be effective in inhibiting copper corrosion. In contrast, chloride ions (Cl−) and sulfate ions (SO42−) have been reported to have corrosive effects, accelerating the corrosion of copper. This study was performed to investigate the effects of adding Cl− and HCO3− in the presence of HEDP, BTA, SiO44−, and Ca2+ on copper pitting corrosion. In natural electrode potential measurements, the addition of HCO3− resulted in a decrease in the steady–state potential and a reduction in the number of pitting corrosion sites. Cl− showed a significantly greater corrosion–promoting effect than SO42−. In anodic polarization curve measurements, the addition of HCO3− broadened the potential range where the current density increased gradually. These results showed that while Cl− exhibited a greater corrosive effect than SO42− the addition of HCO3− resulted in a corrosion–inhibiting effect, suggesting that it can effectively suppress copper corrosion.

    Download PDF (1414K)
  • Taichi Matsumoto, Misato Matsumoto, Fuka Takahashi, Tomoya Takenaka, Y ...
    2026Volume 65Issue 1 Pages 144-148
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Leakage due to carbon film–dependent pitting corrosion in copper tubes used for heat transfer in building air conditioning systems has become a significant problem. To suppress this pitting corrosion, the scale dispersant 1–hydroxyethane–1,1–diphosphonic acid (HEDP) and copper corrosion inhibitor benzotriazole (BTA) were used as corrosion inhibitors. We investigated the effects of chloride ions, sulfate ions, hydrogen carbonate ions, calcium ions, and silicate ions, all of which are water quality constituents, on copper corrosion in the presence of HEDP and BTA. Uncoated carbon–removed samples (copper plates) and samples containing residue carbon (copper tubes) were immersed in aqueous solutions containing HEDP, BTA, chloride ions, sulfate ions, silicate ions, and zinc ions (Zn2+) at different concentrations. The effects of Zn2+ on corrosion resistance of copper were evaluated based on the time variation of the spontaneous immersion potential, the number of corrosion pits observed at the end of immersion, and anodic polarization measurements. Potential measurements showed that the potential of the copper plates increased with higher Zn2+ concentrations, while the potential of the copper tubes remained unchanged. The number of corrosion pits was consistently higher for the copper tubes than the copper plates under all conditions examined. While the number of pits on the copper plates remained nearly constant and was unaffected by Zn2+, the number of pits on copper tubes decreased slightly with increasing Zn2+ concentration. Anodic polarization curves revealed that the addition of Zn2+ lowered the breakdown potential while simultaneously reducing the current density in the region where the increase in current density was slow relative to the change in polarization potential. This study showed that the effects of Zn2+ on copper corrosion resistance in solutions containing corrosion inhibitors were markedly influenced by the carbon film.

    Download PDF (1316K)
  • Misato Matsumoto, Rihoko Aoyama, Fuka Takahashi, Yutaka Yamada, Satosh ...
    2026Volume 65Issue 1 Pages 149-154
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Carbon film–dependent pitting corrosion is caused by the interaction between the carbon film formed on the inner surface of a copper tube and the quality of the water flowing through the tube. It has become a significant issue in air–conditioning equipment. Phosphonic acid (HEDP) and benzotriazole (BTA) are used in field applications to suppress this pitting corrosion. Additionally, it has been found that water quality components such as calcium ion (Ca2+), silicate ion (SiO44−), and bicarbonate ion (HCO3−) are effective. Furthermore, anion exchange–treated water, produced by passing tap water through an ion exchange resin to replace corrosive ions with noncorrosive ions, is one of the techniques used to inhibit corrosion. We have conducted studies on the effect of this treated water on carbon film–dependent pitting corrosion. As a result, it has been confirmed that treated water effectively suppresses carbon film–dependent pitting corrosion in the presence of both HEDP and BTA.

    In this study, the effect of Ca hardness on the corrosion inhibition performance of anion exchange–treated water for copper was investigated.

    Download PDF (1470K)
  • Motoki Kuratani, Itaru Ikeda, Noriyuki Tanaka
    2026Volume 65Issue 1 Pages 155-159
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In copper tubes for heat exchangers used in building services, carbon film–induced Type I pitting corrosion has been a problem. As a simplified method for quantifying the amount of carbon film, we investigated measuring the potential difference (ΔE) between a copper wire and the inner surface of the copper tube. Using this approach, we investigated the standardization of management for carbon film. Our results showed that the treatment method (e.g., grinding, acid treatment) of the copper wire used as the reference electrode affects the measured values. In this study, we investigated the potential behavior of copper wires under different treatment conditions and examined the treatment method for the copper reference electrode used in ΔE measurements. Differences in treatment conditions, such as grinding or acid treatment, affected the potential behavior. The difference due to the type of abrasive paper used was particularly significant. Considering simplicity and reproducibility, the results indicated that acid treatment alone was preferable for the treatment method of the copper reference electrode.

    Download PDF (3931K)
  • Yuya Kawauchi, Ryuto Takeichi, Hikari Watanabe, Isao Shitanda, Masayuk ...
    2026Volume 65Issue 1 Pages 160-165
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Copper tubes are widely used as heat transfer tubes in air conditioners and heat exchangers due to their good corrosion resistance, thermal conductivity, and workability. However, carbon film is formed on an inner surface of copper tubes by burning of the lubricating oil used in the annealing after drawing process during copper tube manufacturing. The carbon film causes pitting corrosion of copper tubes and increases the risk of leakage accidents. In previous studies, the immersion potential difference (hereafter ΔE) between bare copper and carbon–coated copper using a gel electrolyte. The presence of oxygen dissolved in the electrolyte gives the merits and demerits for the ΔE measurement. The amplitude of ΔE is larger in the electrolyte including higher concentration of oxygen because oxygen reduction is active on carbon–coated site and the immersion potential of carbon–coated copper is nobler than that of pure copper. However, in the presence of dissolved oxygen, oxygen acts as an oxidizing agent, causing the dissolution of cupric ions and the formation of cuprous oxide, which leads to a significant change in ΔE with time. Therefore, in this study, ascorbic acid was proposed as a deoxidizer for gel electrolyte, and the ΔE measurements were conducted to investigate the effect of dissolved oxygen on the ΔE measurements. The results revealed that the addition of a small amount of ascorbic acid slightly reduces dissolved oxygen and inhibits the time variation of ΔE.

    Download PDF (1385K)
  • Kaito Kito, Yoshinao Hoshi, Motoki Kuratani, Itaru Ikeda, Noriyuki Tan ...
    2026Volume 65Issue 1 Pages 166-171
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Carbon films formed on the inner surfaces of copper tubes during manufacturing may be associated with the occurrence of pitting corrosion. Therefore, a reliable and simple method for evaluating residual carbon is required. An electrochemical technique based on measuring the rest potential difference (ΔE) between the inner and outer surfaces of copper tubes has been proposed as a simplified evaluation method for residual carbon. In the present study, the effect of chloride ion concentrations on ΔE measurements was investigated to clarify the applicability of this method under chloride–containing environments. In solutions with high chloride ion concentrations, no clear correlation was observed between residual carbon and ΔE. In contrast, in solutions with low chloride ion concentrations, a correlation between residual carbon and ΔE was observed at the initial stage of immersion. Electrochemical impedance spectroscopy was further performed on the inner surfaces of the copper tubes to examine the relationship between the residual carbon and the corrosion rate in each solution. In low–chloride solutions, the corrosion rate increases with increasing residual carbon content. These results indicate that the ΔE–based evaluation method is applicable under low chloride ion concentrations, where ΔE reflects the corrosion behavior associated with residual carbon.

    Download PDF (1441K)
  • Masahiro Sakai, Motoya Takenaka, Takeshi Fujisawa, Kiyotake Sawa, Yuki ...
    2026Volume 65Issue 1 Pages 172-176
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    To investigate the effect of phosphorus content on film formation on copper and the resulting corrosion morphology, electrochemical tests were conducted in a copper formate aqueous solution using six types of copper plates with different phosphorus contents. In potentiostatic polarization tests, ant’s nest corrosion was reproduced on oxygen–free copper and phosphorus–deoxidized copper, whereas hemispherical pitting corrosion was observed on copper plates with a phosphorus content of 0.074% or higher. In addition, hemispherical pitting corrosion was also reproduced by anodic polarization tests for copper plates containing 0.074% or more phosphorus. As the phosphorus content increased, the film formed on the copper surface changed from a cuprous oxide (Cu2O) film to a greenish film. It was found that pitting corrosion occurred when this film shrank and detached during the drying process. Thin–film XRD and FT–IR analyses revealed that the greenish film was basic copper formate. Furthermore, EPMA analysis confirmed the enrichment of phosphorus inside the pits. These results suggest that phosphorus promotes the formation of a basic copper formate film instead of a cuprous oxide film. This film acts as a lid covering the pit, leading to phosphorus enrichment inside the pit and consequently the formation of hemispherical pitting corrosion.

    Download PDF (1918K)
  • Tambang Manik, Masahiro Sakai, Yoshihiko Oishi
    2026Volume 65Issue 1 Pages 177-181
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Localized corrosion can lead to premature failure. Rapid laboratory reproduction of corrosion is crucial for elucidating the underlying mechanisms, controlling its progression, and developing effective mitigation strategies to prevent corrosion. In this study, electrochemical techniques were employed to reproduce localized corrosion on copper specimens induced by acetic acid solutions. Linear sweep voltammetry (LSV) was used to investigate the effect of pH on pit formation in phosphorus–deoxidized copper (PDC) specimens exposed to 100 ppm acetic acid solutions at pH values of 4, 5, 6, 7, and 8. Pit formation was observed only at pH 6 under LSV conditions using a scan rate of 0.1 mV/s after a 30–minute open–circuit potential (OCP) stabilization period, followed by anodic polarization up to 2.0 V vs. Ag/AgCl. This behavior corresponds to a decrease in current density at approximately 1.0 V vs. Ag/AgCl. Furthermore, pitting corrosion at pH 6 was reproducibly induced using chronoamperometry (CA) at a constant potential of 1.00 V. These results demonstrate that pH plays a critical role in pit initiation and growth under controlled electrochemical conditions, and that localized corrosion can be rapidly reproduced using LSV and CA within a short laboratory timescale.

    Download PDF (1446K)
  • Yuki Koshika, Kiyotake Sawa, Karen Nakamura
    2026Volume 65Issue 1 Pages 182-187
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In air–conditioning applications, an increasing number of premature failures of copper tubing for indoor units occur due to ant’s nest corrosion after a short period of service in highly airtight and insulated homes. To tackle the problem, adoption of oxygen–free copper (C1020) has been the classic option as an alternative to conventional phosphorus–deoxidized copper (C1220) in HVAC industries across the globe. Our previous research found that pH measurements of condensed water collected from indoor units using C1020 in highly airtight and insulated homes were significantly lower than those found in general homes free of leakage. In this research, the effect of high concentration of CO₂ in O₂ atmosphere on the corrosion morphologies of C1020 was assessed. In the corrosion test conducted for 20 days using a 0.01vol% formic acid solution, ant’s nest corrosion morphologies were observed in only one of the three C1020 tubes under low temperature cooling cycles with CO₂. In contrast, all the C1220 tubes exhibited ant’s nest corrosion morphologies with and without CO₂ under the low temperature cooling cycles. Another corrosion test was conducted on C1020 to determine the time to leakage. In this test, the inner surface was pressurized with nitrogen gas to 1 MPa, while the outer surface was exposed to the corrosion environment as described previously. During the test, the time to leakage was evaluated by measuring pressure loss with a pressure gauge. The results demonstrated that all the C1020 tubes leaked in 607–816 h with CO₂, whereas only one out of three tubes leaked in 604 h and the other two lasted beyond 956 h without leaking. Furthermore, during the above–mentioned corrosion tests, the pH of condensed water on the test vessel wall was measured, and it was found that the pH was 3.9 and 4.1 respectively with and without CO₂, which revealed that the former was 0.2 lower than the latter. These results suggest that the dissolution of CO₂ into the condensed water on the surface could slightly lower the pH inside the corrosion pits, thereby developing the corrosion into ant’s nest morphologies even in C1020 tubes which are supposed to have superior resistance to ant’s nest corrosion than C1220 tubes.

    Download PDF (1983K)
Plating, Surface
  • Shintaro Yamamoto, Hirotaka Ito, Sho Katsura, Masahiro Tsuru, Keiichir ...
    2026Volume 65Issue 1 Pages 188-192
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Demands for platings with high wear resistance, electrical conductivity, and heat resistance are increasing for charging connectors used in electric vehicles. In this study, a silver plating incorporating acrylic resin particles with excellent lubricity was developed, and its various properties and microstructure were evaluated.

    The silver-resin composite plating exhibited excellent wear resistance of more than 45,000 sliding cycles per 10 µm of plating thickness, while maintaining a low contact resistance comparable to that of pure silver plating. In addition, the plating demonstrated sufficient heat resistance under a high-temperature environment of 180°C for 500 h.

    It was revealed that a nanoscale carbon thin film is formed on the outermost surface of sliding area of the silver-resin composite plating. This carbon film is considered to suppress adhesive wear of silver during sliding, thereby contributing to the improved wear resistance.

    Download PDF (2086K)
  • Yumi Hattori, Shunsuke Mori, Peng Wang, Erli Lin, Hidetoshi Miyazaki, ...
    2026Volume 65Issue 1 Pages 193-198
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In recent years, high–heat–dissipating materials have become increasingly important due to the rising power output of electronic devices. In this study, Cu–Graphene composite films were fabricated and characterized by Graphene utilizing both for its high thermal conductivity and as an additive to control crystal growth. Surface observations revealed that Graphene agglomerates were present throughout the coating surface, leading to a unique and characteristic surface morphology. Regarding the crystal structure, fabrication at low current density induced a pinning effect by Graphene on the (111) plane, shifting the preferred orientation to the (220) plane. This structural control increased the crystallite size to 73.1 nm (approximately 1.6 times that of pure Cu coatings) and successfully reduced the grain boundary density, which acts as thermal resistance. In contrast, fabrication at high current density resulted in a hierarchical structure composed of macro–scale irregularities from Graphene and micro–scale crystal structures, exhibiting a significant hydrophobicity with a maximum contact angle of 121.0°. This hydrophobicity is attributed to a trapped air layer that is considered to shield the surface from moisture. Consequently, the suppression of initial oxidation is then expected to preserve the original high thermal performance. Thermal conductivity measurements reached a maximum of 299 W/(m·K) on Cu alloy substrates, which is approximately 5 times that of Cu alloy substrate. Furthermore, when using pure Cu substrates, the conductivity reached the study’s peak value of 618 W/(m·K). In conclusion, the composite films developed in this study achieved both high thermal conductivity and hydrophobic functionality through Gr–mediated crystal structure control. This material is highly promising for the thermal management of next–generation power devices.

    Download PDF (1803K)
  • Shunsuke Mori, Yumi Hattori, Peng Wang, Erli Lin, Hidetoshi Miyazaki, ...
    2026Volume 65Issue 1 Pages 199-204
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    In recent years, the rapid miniaturization of electronic devices has made efficient thermal management an urgent issue. Although nickel plating is widely used on copper substrates, its low thermal conductivity acts as a significant thermal resistor. To overcome this barrier, we fabricated novel high–thermal–conductivity Ni–Graphene composite plating films on Cu alloys by using a hybrid electroplating method in two types of plating baths:a sulfuric acid bath and a chloride bath. The crystal structure and surface morphology strongly depended on the bath composition. Sulfuric acid–derived films exhibited coarse pyramidal crystals with a Ni(200) preferred orientation. Conversely, chloride bath films prepared at a high current density formed a unique mesh–like structure composed of fine needle–like crystals. These films demonstrated a strong Ni(111) preferred orientation, crystal refinement down to 36.84 nm due to graphene’s pinning effect, significant surface roughness (Ra=20.20 µm), and excellent water repellency with a contact angle of 133°. Remarkably, the Z–axis thermal conductivity of the chloride–derived Ni–Graphene film reached an astonishing 729 W/m·K. This is approximately 5.7 times higher than pure Ni–plated (51 W/m·K) films and 12.5 times higher than the Cu substrate (58 W/m·K). This drastic enhancement can be attributed to graphene’s intrinsic thermal properties, suppressed phonon scattering via the dense Ni(111) orientation, and the “micro–fin effect” from the 3D needle–like structures increasing the effective heat diffusion area. Therefore, these low–cost Ni–Graphene composite films are highly promising heat dissipation materials for next–generation power devices.

    Download PDF (1684K)
  • Shuichi Kitagawa
    2026Volume 65Issue 1 Pages 205-208
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The influence of plating microstructure on contact properties of tin plating was investigated. In this study, the tin plating was thinned and Cu-Sn intermetallic compound layer was exposed on the surface after the reflow treatment. The two different platings were compared in which one consisted of conventional reflowed tin plating and the other consisted of Cu-Sn plating with the surface predominantly composed of the Cu₆Sn₅ intermetallic compound. The reflowed tin plating exhibited increase in contact resistance due to the fretting oxidation during the sliding test and, on the other hand, the Cu-Sn plating suppressed wear, keeping stable contact resistance. Both platings demonstrated sufficient corrosion resistance. The solder wettability of the Cu-Sn plating degraded after heat exposure and, however, it was improved by electrolytic reduction treatment. These results demonstrate that the Cu-Sn plating maintains practical reliability, effectively suppressing increase in contact resistance induced by the fretting.

    Download PDF (1673K)
  • Mana Kitano, Koya Maeda, Shigekazu Watanabe, Yoshie Tarutani, Hironobu ...
    2026Volume 65Issue 1 Pages 209-214
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The increasing number of terminals in automotive communication connectors has resulted in a larger force being required during connector assembly. Since the insertion force of terminals is strongly influenced not only by terminal structure but also by the surface condition at electrical contact interfaces, the plating structure applied to the contact surface plays an important role. Reflow tin plating is widely used for automotive connector terminals. During the reflow process, a copper-tin (Cu-Sn) intermetallic compound layer is formed beneath the outermost pure tin layer. In this study, the morphology of Cu-Sn intermetallic compound was investigated. Sliding tests simulating pin and socket terminals were conducted to examine the effects of intermetallic compound morphology and combinations of these morphologies on the dynamic friction coefficient. The Cu-Sn intermetallic compound morphology was evaluated using Spc (surface arithmetic mean peak curvature) and particle circularity as quantitative indices, and dynamic friction coefficients were measured by combining convex-embossed and flat specimens. The results indicate that friction during sliding is governed by the combined contribution of adhesive interaction originating from the pure tin surface layer and mechanical resistance associated with overcoming the surface asperities of Cu-Sn intermetallic compound. On the pin terminal side, where the contact position continuously changes during sliding, the influence of surface asperities is significant, and a relatively rounded Cu-Sn intermetallic compound morphology is effective. In contrast, on the socket terminal side, applying a sharper Cu-Sn intermetallic compound morphology that limits the contact area is effective in reducing the dynamic friction coefficient.

    Download PDF (1517K)
  • Seung Zeon Han, Munsu Choi, Hidemi Kato, Satoshi Semboshi, Eun–Ae Choi
    2026Volume 65Issue 1 Pages 215-220
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    We investigated the interfacial stability between Cu₂O and Cu solid solution alloys containing 1 wt% Zn, Ni, and Mn under atmospheric and reduced–pressure oxidation. At 1/10000 atm, coarse Cu₂O grains formed in intimate contact with the substrate, and Mn– and Zn–containing alloys exhibited high dislocation densities, indicating strain accommodation through geometrically necessary dislocations that preserved interfacial bonding. In contrast, oxidation at 1 atm resulted in low dislocation densities due to premature interfacial delamination and strain relaxation. The Cu–Mn alloy maintained high dislocation density even at 1/5000 atm, whereas the Cu–Ni alloy showed lower values associated with partial separation. Although the thicknesses of the oxide films formed on Cu–Ni and Cu–Mn alloys were similar at 700°C, the Cu–Mn alloy exhibited a blue color shift, implying that Mn incorporation alters the intrinsic optical properties of the oxide rather than producing a thickness–dependent color effect.

    Download PDF (2289K)
Joining
  • Shinji Fukumoto, Ryosuke Ueno, Michiya Matsushima
    2026Volume 65Issue 1 Pages 221-226
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    This study proposes a novel bonding method in which small projections are formed in situ at the interface between a copper substrate and a thermoset epoxy resin during the curing process. To achieve simultaneous bonding and projection formation, an epoxy resin was mixed with two types of metallic particles: high‑melting‑point Cu particles and low‑melting‑point Sn–Bi alloy particles. During heating, both particles sedimented toward the copper substrate before the onset of resin curing. When the temperature exceeded the melting point of the Sn–Bi alloy, the molten Sn–Bi wetted and bonded the Cu particles to the copper substrate, resulting in the formation of Cu projections on the interface. The experimental results revealed that the sedimentation behavior of both particles could be controlled by optimizing resin viscosity and curing temperature. Cross‑sectional observations confirmed that overhanging Cu projections were successfully formed for Sn–Bi contents up to 3.0 vol%. These projections provided a strong mechanical interlocking effect, significantly enhancing the interfacial shear strength compared with joints without projections. The maximum shear strength of approximately 11 MPa was obtained at a Sn–Bi content of 1.5 vol%. Excess Sn–Bi, however, filled the gaps between Cu particles and reduced the overhanging morphology, leading to lower mechanical interlocking efficiency. This in situ projection‑forming bonding technique provides an effective and process‑integrated method for enhancing adhesion at resin/metal interfaces.

    Download PDF (6024K)
  • Nanako Uematsu, Sota Aoki, Ryo Saito, Yasuyuki Miyazawa, Yasuhiro Tsuk ...
    2026Volume 65Issue 1 Pages 227-231
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The trend toward multi–material industrial products is advancing to achieve goals like carbon neutrality. Joining technologies between dissimilar metallic materials are essential for this multi–materialization. However, dissimilar metallic materials exhibit differing physical properties such as melting points, thermal expansion coefficients, and thermal conductivity coefficients.

    While brazing is considered suitable for joining dissimilar metallic materials, creating a sound interface through brazing between them is known to be difficult.

    Previous research indicates that precisely controlling the amount of molten brazing filler metal during brazing is difficult. Although research continues, no solution has yet been demonstrated.

    Therefore, this study proposes a method where the base metal is rotated during brazing to forcibly expel molten filler metal outside the brazed joint.

    Reducing the amount of brazing filler metals often leads to a reduction in the thickness of the brazing zone. A thinner brazing zone can increase the strength of the brazed joint. Furthermore, we believe that expelling the molten brazing material outward can suppress the formation of intermetallic compounds and other phases at the interface.

    The base materials used were free–cutting brass and austenitic stainless steel SUS304L. The brazing filler metal used was BAg–7, a foil–type silver–based brazing filler metal. Brazing was performed in a vertical electric furnace. The brazing temperature was approximately 700°C, with a brazing hold time of 5 minutes. Rotation was applied at 100 rpm.

    For brazing evaluation, microstructural observation was performed using an optical microscope, and mapping elemental analysis was conducted using EPMA for analysis.

    Download PDF (2371K)
  • MingHsu Weng, Yosuke Matsumura, Yasuyuki Miyazawa, Kyohei Furihata, Hi ...
    2026Volume 65Issue 1 Pages 232-236
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Brass is mainly used in piping components,. However, the Drinking Water Quality Standards Law restricted the amount of lead addition. Lead–free brass was developed by addition of alternative elements such as Bi and Si. Brazing is also essential as a joining technique when used in piping components. Dezincification occurring during heat treatment is caused by zinc’s low melting point, cause it to desorb out of the base metal. It has been demonstrated that zinc leaches out of brass, leaving only copper with cavities. As a result, the performance of the brazed body may be impaired. Currently, the problem of dezincification phenomenon of brass is causing overall brass degradation, affecting product performance and lifespan. Current solutions include lowering brazing temperatures and brazing under zinc vapor atmospheres. However, these do not provide a fundamental solution. Therefore, the purpose of this study is to investigate the effects of heating temperature and time on the dezincification phenomenon, conduct a detailed examination of its impact on the microstructure of brass brazed joints, and clarify the dezincification mechanism.

    Download PDF (6515K)
  • Kotaro Kobayashi, Kaito Ogino, Yasuyuki Miyazawa, Hideki Sekiguchi, Ta ...
    2026Volume 65Issue 1 Pages 237-241
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    This study investigated the effects of brazing temperature and the behavior of additive elements on the joint strength of dissimilar metal brazed joints between Bi–containing Pb–free brass C6801 and austenitic stainless steel SUS304. A silver–based brazing filler metal, BAg–7, was used, and furnace brazing was conducted at 700°C and 740°C. Tensile tests were performed on the brazed specimens, and fracture surface observations and EPMA elemental mapping analyses were carried out to evaluate interfacial reactions and elemental diffusion behavior.

    The results showed that the maximum tensile strength of the joint brazed at 700°C was 251 MPa, whereas that brazed at 740°C decreased to 170 MPa. EPMA analysis revealed that Bi contained in the brass substrate migrated into the molten filler metal and tended to segregate at the SUS304–side interface. In addition, a Ni–depleted layer was formed on the SUS304 side due to the diffusion of Ni into the brazing filler metal. It was also found that Bi preferentially penetrated and segregated along the grain boundaries within this Ni–depleted layer. These interfacial phenomena are suggested to cause grain boundary embrittlement and consequently contribute to the reduction in brazed joint strength.

    Download PDF (3367K)
  • Ryo Saito, Nanako Uematsu, Sota Aoki, Yasuyuki Miyazawa, Kyohei Furiha ...
    2026Volume 65Issue 1 Pages 242-246
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Brass is made by joining it with other materials. Among them, bonding with stainless steel is mainly used in plumbing components such as water pipes. Brass contained lead. However, in recent years, it has been found that the lead contained in brass has a toxic on the human body in products using brass, and the revision of the Drinking Water Quality Standards Act has regulated the lead in brass to less than 0.025mass%. Examples of harm to the human body caused by lead include headaches and gastrointestinal problems.Pb Free brass has been put to practical use and utilized in many places. Bi–containing brass has excellent machinability, similar to Pb–containing free–cutting brass, and possesses very similar properties [1]. Brass is commercialized through machining processes such as cutting, forging, and brazing. Previous studies have shown that added elements such as Bi and Si affect brazing, and that are particularly strongly affected by brazing temperature. On the other hand, the effect of Bi, an added element, on the interfacial reaction during brazing is unknown. Therefore, in this study, the effect of Bi content on interfacial reactions was investigated.

    Download PDF (3614K)
  • Yasunori Harada, Kouki Kawai, Masayuki Nunobiki, Toshinori Aoki
    2026Volume 65Issue 1 Pages 247-253
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    There are many techniques for joining dissimilar materials in thin sheet, such as welding and friction stir welding. In this study, we attempted to join dissimilar materials using shot peening. The test materials were pure copper C1100 and resin sheet PC (polycarbonate) with thicknesses of 1 mm. The microshot and the air–type machine were used for peening the butt joint. The peening pressure was 0.6 MPa, and the peening time ranged from 10 to 100 seconds. The butt joints had an uneven shape, specifically a tapered trapezoid. Shot peening was performed on both sides of the joint. The bondability was evaluated by tensile test. The joint was observed under a microscope. The impact of the fine particles caused plastic deformation in the surface layer of the joint, resulting in a caulking effect. The method presented in this study demonstrated that butt joints between dissimilar thin sheets are feasible.

    Download PDF (12921K)
  • Fumio Kanazaki, Hideki Sekiguchi, Yasuyuki Miyazawa
    2026Volume 65Issue 1 Pages 254-258
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    It is well known that, in free–cutting brass, the addition of Sn to form the γ phase effectively suppresses the progression of dezincification. When Sn is added, brass becomes a three–phase system consisting of the α, β, and γ phases, whereas without Sn addition, it forms a two–phase system of the α and β phases. Similarly, in lead–free free–cutting brass, Sn is added for the purpose of inhibiting dezincification. However, when lead–free free–cutting brass is brazed to austenitic stainless steel (SUS304), the migration of Bi into the molten brazing filler metal is observed. In this study, experiments were conducted using C6801 and C6803, which have nearly identical Bi content but different Sn content. The results confirmed that in C6803 (which contains about five times more Sn than C6801), the thickness of the dissolution layer increased with rising brazing temperature. Based on these results, this paper provides a detailed examination and discussion of the influence of Sn content on both the width of the dissolution layer and the migration behavior of Bi into the molten brazing filler metal.

    Download PDF (3488K)
Metal Processing
  • Yosei Onuki, Hideo Takizawa
    2026Volume 65Issue 1 Pages 259-265
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The use of copper alloys will increase as electric transport becomes more popular. To reduce vehicle weight, high-strength alloys are developed, and part shapes become more complex. Numerical simulation will be required for the process design of sheet metal forming of copper alloys. To achieve accurate sheet metal forming analysis, it is necessary to measure and model the yield surfaces under biaxial stress states. However, few studies have measured and modelled the anisotropic yield surface of copper alloys. The authors developed simplified equipment for cruciform biaxial tensile tests using rope and pulleys. The equipment can be installed in a conventional universal testing machine. In this study, the yield surfaces of tough-pitch copper with different temper rolling (C1100-O, 1/2H, and H) are measured using the equipment as a preliminary investigation. The measured stress points on the equal plastic work contour are modelled by the anisotropic yield function Yld2000-2d, which is widely used for aluminium alloy sheets.

    Download PDF (4299K)
  • Liu Haidong, Takeshi Sawai
    2026Volume 65Issue 1 Pages 266-271
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Free–cutting brass exhibits excellent machinability due to its lead content and can be machined without the use of cutting fluid. However, the EU RoHS Directive restricts lead content to 0.1 wt% or less, and this directive must be complied with when exporting to the EU market. The use of lead–free brass is therefore required. However, without the solid lubrication action of lead, the machinability of lead–free brass is inferior, leading to frictional wear, heat generation, and reduced chip flow, especially in microdrilling. To address this, cutting fluids containing extreme–pressure additives are used. Extreme–pressure additives provide lubrication action under high–pressure conditions and are of utmost importance in cutting work. Conventionally chlorinated paraffins were used for this purpose but having been found to have negative effects on the environment, they are currently designated for abolition. It is therefore important to verify the performance of new extreme–pressure additives for this application.

    In this study, using a chlorinated paraffin and a sulfurized olefin as the extreme–pressure additive, we microdrilled C2801 brass using cutting fluids containing these additives in various proportions in the base oil. The results showed that using a sulfurized olefin instead of a chlorinated paraffin as the extreme–pressure additive extended drill life. Using a cutting fluid with 60 wt% of the chlorinated paraffin added, the drill life reached 500 holes, whereas, using a cutting fluid containing the sulfurized olefin, a drill life of 500 holes could be reached at a low additive rate of 40 wt%. We found that this was because the extreme–pressure additive promoted finer chip fragmentation, and adding the sulfurized olefin at 60 wt% or more resulted in crushed chips and improved chip flow compared to the chlorinated paraffin.

    Download PDF (4756K)
  • Suketohi Takano, Hideharu Kato, Shigehiko Sakamoto, Koichi Suzaki, Jin ...
    2026Volume 65Issue 1 Pages 272-277
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Brass is widely used in precision components owing to its high conductivity, dimensional stability, and corrosion resistance. Traditionally, lead has been added to improve machinability, but environmental regulations such as RoHS have accelerated the adoption of lead–free brass. While these materials generally exhibit stable machinability in conventional operations such as turning and milling, small–diameter drilling frequently encounters chip–evacuation difficulties, leading to excessive tool wear and unexpected tool breakage. Consequently, the chip–formation and evacuation mechanisms during high–aspect–ratio micro–drilling of lead–free brass remain insufficiently understood. Meanwhile, the ongoing miniaturization of electronic devices has increased the demand for high–precision micro–holes with strict dimensional accuracy. Although laser drilling enables high processing speed, it often produces tapered hole geometries at high aspect ratios. In contrast, mechanical drilling can achieve superior dimensional accuracy and straightness, making it suitable for precision applications. In this study, chip–evacuation behavior in deep–hole micro–drilling of lead–free brass was investigated using 0.5 mm and 0.3 mm diameter drills under minimum quantity lubrication (MQL) conditions. Drilling experiments were performed while varying the feed rate, and machining stability was evaluated based on tool condition and drilling performance. The results showed that stable machining was achieved up to an aspect ratio of 10, whereas higher aspect ratios led to tool breakage caused by feed–rate reduction and insufficient lubrication at the cutting edge. Furthermore, stable drilling with the 0.3 mm diameter drill was achieved at a feed rate of 0.05 mm/rev.

    Download PDF (3180K)
Melting, Casting
  • Yuta Nakamura, Yuichi Motoyama, Toshimitsu Okane
    2026Volume 65Issue 1 Pages 278-285
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    Understanding the tensile behavior of copper alloys in the semi–solid temperature region is essential for predicting and preventing hot tearing during direct‑chill casting of copper alloys. Using a custom high‑frequency induction heating tensile apparatus, tensile tests of a Cu–3.2 wt%Ti were performed across a wide range of fraction solid (fs) of 0.40–0.84, enabling detailed analysis of the evolution of tensile strength and crack initiation strain during solidification. Furthermore, this study quantified the tensile response of the Cu–3.2 wt%Ti alloy by obtaining the stress–displacement curves. Two critical fractions were extracted:a coherency point at fs=0.39 where dendrites begin to bear load, and a coalescence point at fs=0.73 where inter‑dendritic bonding rapidly increases strength. At the fraction solid range between 0.40–0.79, the alloy fractured in a brittle manner with crack‑initiation strains < 1%, indicating a high hot‑tearing risk. At fs > 0.79, ductility rose steeply. Fractography and stress–displacement curves delineated four zones:(i) liquid‑surrounding dendrites with no strength, (ii) brittle behavior governed by thin liquid films, (iii‑a) high strength but instantaneous fracture triggered by isolated liquid pockets, and (iii‑b) increasing ductility with plastic yielding. This study further suggested employing multiple hot tearing criteria tailored to regimes (ii) and (iii‑a)—liquid‑feeding‑based criteria and fracture‑mechanics‑based criteria—to improve hot tearing predictions for Cu–Ti alloys. Using the semi-solid tensile data, a hot tearing analysis was conducted for direct-chill casting of the Cu–3.2 wt%Ti alloy via thermal stress simulation. The analysis indicated that hot tearing in zone (ii) is strongly affected by primary cooling;consequently, to suppress hot tearing while improving ingot productivity, it is analytically suggested that strengthening secondary cooling—rather than intensifying primary cooling—is principally effective.

    Download PDF (5477K)
  • Takeshi Nagase, Michiru Yamashita, Kazuyoshi Waseda, Katsumi Nakashima ...
    2026Volume 65Issue 1 Pages 286-291
    Published: 2026
    Released on J-STAGE: November 04, 2026
    JOURNAL FREE ACCESS

    The Shinkoro clock tower, located in Izushi–Town, Toyooka–City, Hyogo Prefecture, Japan, is recognized as one of the symbolic structures in Toyooka–Izushi Preservation Districts for Groups of Traditional Buildings. Now, a fourth–generation Shinkoro–Tower–Clock provides the accurate time to both residents and visitors. Based on historical records, the first–generation Shinkoro–Tower–Clock was a mechanical tower clock and began operation in Izushi area from September 1881. It has been clarified that the second Shinkoro–Tower–Clock was a mechanical tower clock, designed and manufactured in Akashi–City, Hyogo Prefecture, in 1953. This study reports the compositional analysis results of metal components made by Cu–based alloys in the first and second generations of the Shinkoro–Tower–Clocks by X–ray Fluorescence spectroscopy.

    Download PDF (3664K)
feedback
Top