This study examined the effects of multi-ply adhesive and an insulating layer on the residual stress generated in the copper foil portions of a copper clad laminate composed of copper foil/FRP/copper foil. First, copper clad laminates were formed by the hot press method using various multi-ply adhesives as well as various insulating layers. Then, residual stress in the copper foil portions of these samples was measured by the strain gauge method of the layer-removing. The thermal and mechanical properties of the multi-ply adhesive and the insulating layer were measured, and the residual stress of the copper foil portion was analyzed together with these various proper-ties. The following results were identified:
(1) The residual stress generated in the copper foil portion depends more on the coefficient of linear expansion of the mirror plate, multi-ply adhesive, and insulating layer than on that of the copper foil. And, it grows hereafter in order of (I) < (II) < (III) .
(I) α
P=α
A=α
F(II) α
F<α
P<α
A or α
A<α
P<α
F(III) α
P<α
F<
A or α
P<α
A<α
F, α
F<α
A<α
P or α
A<α
F<
PWhere, α
P: coefficient of linear expansion of mirror plate, α
A: coefficient of linear expansion of adhesive, α
F: . coefficient of linear expansion of insulating layer.
(2) The residual stress generated in the copper foil portion can be reduced by controlling the coefficient of linear expansion of the multi-ply adhesive.
View full abstract