Japanese Journal of Biofeedback Research
Online ISSN : 2432-3888
Print ISSN : 0386-1856
Current issue
Displaying 1-4 of 4 articles from this issue
Original Article
  • Daisuke FUJIMOTO, Masahito SAKAKIBARA
    2026Volume 53Issue 2 Pages 49-57
    Published: October 25, 2026
    Released on J-STAGE: October 25, 2026
    JOURNAL FREE ACCESS

      Interoception is the process of perceiving and integrating internal bodily states, and the heartbeat counting task, a representative assessment method, has been noted to have methodological problems. We employed the heaviness perception test as an interoceptive measure that is relatively independent of cognitive and linguistic abilities. Because heart rate variability biofeedback (HRVB) may act on interoception through vagal afferent pathways, performance on the heaviness perception test would be expected to improve after the intervention if the test indexes interoception. This study therefore examined the validity of the test from the perspective of its responsiveness to intervention. Thirty-four healthy adult men were randomly assigned to an HRVB group or a control group. The HRVB group performed paced breathing at their resonance frequency and the control group at 15 cpm, each for 20 minutes. Before and after the intervention, the heaviness perception test, Japanese versions of the Interoceptive Accuracy Scale (IAS-J), and a relaxation scale were administered, and heart rate variability indices (mean RR interval : RRI, standard deviation of all NN intervals : SDNN, root mean square of successive differences : RMSSD, and the amplitude of respiratory sinus arrhythmia : RSA) were measured at rest and during the task. SDNN, RMSSD, and RSA amplitude increased significantly in the HRVB group (p<0.001). The accuracy of the heaviness perception test and the relaxation scale both improved significantly after the intervention in the HRVB group (p<0.001 ; p=0.008). These findings suggest that HRVB improved the accuracy of the heaviness perception test. Integrated with the cross-sectional findings of previous research, the heaviness perception test appears promising as an index for capturing interoceptive accuracy.

    Download PDF (1300K)
Short Report
  • Yuichiro NAGANO, Masahiro SHIGETA
    2026Volume 53Issue 2 Pages 58-66
    Published: October 25, 2026
    Released on J-STAGE: October 25, 2026
    JOURNAL FREE ACCESS

      This study aimed to develop and conduct a preliminary evaluation of an AI agent that integrates multiple physiological and behavioral indicators derived from activity trackers (AT) to provide personalized feedback. Data on step count, sleep duration, heart rate variability, and resting heart rate were obtained from Fitbit devices, and time-series line graphs were generated. These visualized data were then input into a large language model to generate natural language feedback. Furthermore, a system was developed to present feedback through both visual and auditory modalities by combining a CG avatar with speech synthesis. A total of 30 university students participated in an 8-week comparative study, consisting of an AI agent intervention group and a control group that received graphical feedback only. Usability and reflective reports were evaluated. The results showed that the perceived usefulness tended to be higher in the AI agent group; however, no statistically significant differences were observed. In contrast, qualitative responses indicated positive effects, including improved understanding of health data, increased health awareness, and enhanced motivation for behavioral change. Additionally, the AI agent was perceived as a social entity functioning as an advisor. These findings suggest that the developed AI agent may contribute to supporting data interpretation and sustaining motivation in daily biofeedback using activity trackers. However, given the lack of statistically significant effects, further improvements in system stability and usability, as well as more rigorous evaluation, are required.

    Download PDF (2030K)
Technical Note
  • Zhenni SHI, Yuto NAGATA, Yuichiro NAGANO, Yusuke MORITA
    2026Volume 53Issue 2 Pages 67-79
    Published: October 25, 2026
    Released on J-STAGE: October 25, 2026
    JOURNAL FREE ACCESS

      This study examined the effectiveness of a mixed-reality (MR) Chinese language learning application incorporating bio-feedback indicators. Designed using Total Physical Response (TPR) theory and interactive elements, the system aims to enhance learner engagement. Twenty participants (average age=23 years) took part in an experiment using subjective scales and physiological measures, including skin conductance (SC), heart rate (HR), and the root mean square of successive differences (RMSSD). The results showed increased emotional engagement in TPR-based sections. Physiological data indicated higher arousal during learning than at rest. Additionally, decreased HR and increased RMSSD suggest activation of the parasympathetic nervous system. These findings highlight the potential of biofeedback to objectively evaluate emotional and cognitive engagement in immersive learning environments.

    Download PDF (2586K)
Annual Meeting
feedback
Top