日本放射線安全管理学会誌
Online ISSN : 1884-9512
Print ISSN : 1347-1503
ISSN-L : 1347-1503
10 巻, 1 号
選択された号の論文の43件中1~43を表示しています
震災に対するご挨拶
歴代会長挨拶
第9回学術大会(広島)
特別講演1
特別講演2
特別講演3
受賞講演
招待講演1
招待講演2
セッションのまとめ
大会賞
原著
  • 三浦 美和, 森田 直子, F. LUKMANUL HAKKIM, 吉田 正博, 松田 尚樹
    2011 年 10 巻 1 号 p. 33-39
    発行日: 2011年
    公開日: 2011/12/20
    ジャーナル フリー
      The exposure of animals or cultured cells to radiation is the essential and common step in experimental researches to elucidate biological effects of radiation. When an X-ray generator is used as a radiation source, physical parameters including dose, dose rate, and the energy spectrum of X-ray play crucial roles in biological outcome. Therefore, those parameters are the important points to be checked in quality control and to be carefully considered in advance to the irradiation to obtain the accurate and reproductive results. Here we measured radiation dose emitted from the X-ray irradiator for research purposes by using clonogenic survival of cultured mammalian cells as a biological marker in parallel with physical dosimetry. The results drawn from both methods exhibited good consistency in the dose distribution on the irradiation stage. Furthermore, the close relationship was observed between cell survival and the photon energy spectrum by using different filter components. These results suggest that biological dosimetry is applicable to quality control of X-ray irradiator in adjunct to physical dosimetry and that it possibly helps better understanding of the optimal irradiating condition by X-ray users in life-science field.
技術報告
  • 藤淵 俊王, 井上 創, 小原 哲, 加藤 英幸, 小林 育夫, 細田 正洋
    2011 年 10 巻 1 号 p. 40-45
    発行日: 2011年
    公開日: 2011/12/20
    ジャーナル フリー
      Crookes tube is used on an educational site in the junior high school and the high school, etc. for the purpose to learn the character of cathode rays. When using the tube, X rays are generated, however, there is few example of confirming in which direction to scatter in detail. Understanding how the distribution of the leakage dose is important because of efficient exposure decrease. The distribution of X rays generated from Crookes tube was measured by arranging imaging plates in six surroundings to enclose Crookes tube. The electron collided with a metal target and X rays had extended backward. The dose was greatly different depending on the direction. When experimenting with Crookes tube, it is necessary to consider not only the dose but also distribution.
特集(教育)
広場
論説
放射性ヨウ素安全対策アドホック委員会
メンタルケア委員会
feedback
Top