-
原稿種別: 表紙
1981 年 37 巻 6 号 p.
Cover16-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 表紙
1981 年 37 巻 6 号 p.
Cover17-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 目次
1981 年 37 巻 6 号 p.
Toc6-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
山岸 一雄
原稿種別: 本文
1981 年 37 巻 6 号 p.
i-ii
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
1-6
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
花田 博之
原稿種別: 本文
1981 年 37 巻 6 号 p.
722-728
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Seven low-pass digital filters which were synthesized previously by the author are applied to 64×64 matrix images of a IAEA liver phantom, which is filled with 9.25×10^7Bq (2.5mCi) ^<99m>Tc aqueous solution, from a scintillation camera. Three matrix images are made an object of investigation and total counts of them are 30k counts, 100k counts and 600k counts respectively. First, low-pass digital filterings by convolution are performed to the matrix images and the processed images are observed about image quality. When the filter with the smallest cutoff frequency, which was called Filter A, was used, the fact was shown that almost all the informations in the processed images for three kinds of count data disappeared. Finally, subtractions between the processed image by Filter A and the processed image by another filter are performed for each count data. The consequences of these processings are as follows : (1) The low-pass filtering is effective in improvement of image quality for 30k count image and 100k count image. However, this method does no good in 600k count image. (2) The subtraction results in a success about image restoration with the supression of noise and the reduction of blur, and this method is superior in improvement of image quality to the low-pass filtering. On the other hand the processing conditions for image restoration depend on the count level of the image.
抄録全体を表示
-
矢野 今朝人, 丸山 清, 滝沢 正臣, 竹村 克人
原稿種別: 本文
1981 年 37 巻 6 号 p.
729-737
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Fundamental study for radiation treatment planning using the electron density deduced from the CT number was described. In order to deduce the electron density of CT-5005 (EMI) wholebody image from the CT number, the following expressions were used : Es=(0.00339×CT number+3.39)×10^<23> for soft tissue such as lung, fat and muscle. Eh=(0.00120×CT number+3.34)×10^<23> for hard tissue such as bone. Dose calculation of the central axis depth dose was performed in a one field irradiation. For the correction of tissue inhomogeneity such as lung and bone, the pixel by pixel method was used. In this study, the following points were concluded. (1) The maximum difference between the electron density deduced from the CT number and the electron density produced from the technique of dual energy scanning or the theoretical method was within 2.3%. (2) In order to reduce the relative percent error of the central axis depth dose less than 2% at 10MV x-rays, the permitted limit of electron density error was 10% for the average electron density of the lung. But, if the relative percent error is permitted within 2%, the correction of tissue inhomogeneity was not necessary for the abdomen and the waist. (3) In order to reduce the relative percent error of the central axis depth less than 2% at 10MV x-rays, it was possible to deduce the original matrix size (256×320) into 64×80 matrix.
抄録全体を表示
-
東田 善治, 松本 政典, 吉田 日出輝, 洞田貫 誠志, 守部 伸幸, 松下 元一, 河野 直久, 勝田 勝, 大塚 昭義
原稿種別: 本文
1981 年 37 巻 6 号 p.
738-746
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Entropy analysis to psychological evaluation for tomographic images is applied. An optic canal and an internal ear tomogram are taken by hypocycloidal, elliptical, spiral and circular blurring movements. Fifteen tomograms are taken for each tomographic blurring movement of the two different parts, so a total of 60 sheets of tomograms are taken. All optic canal tomograms are evaluated by two groups composed of five ophthalmologists and five radiologic technologists, and internal ear tomograms are evaluated by five otolaryngologists and five radiologic technologists. Each observer participated in this experiment twice, so the total number of tomograms are 120 sheets per ovserver. The subjects were directed to classify 120 tomograms by using a three-category rating scale. Characteristics of each ovserver and each group can be shown quantitatively by caluculated information values.
抄録全体を表示
-
大塚 昭義, 宇津見 博基, 山根 智, 横山 敬, 中西 敬, 山田 典将, 橋田 昌弘, 伊藤 実穂, 東田 善治, 木谷 猪佐夫, 大 ...
原稿種別: 本文
1981 年 37 巻 6 号 p.
747-754
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Uncertainty analysis by entropy is applied to a method of psychological evaluation in radiographic images and to an examination of visual evaluation of sharpness in radiograms. Subjects are composed of three groups of seven radiologic technologists, seven neurosurgeons and eight radiologists. By using a three-category rating scale, each observer is directed to classify 160 skull radiograms randomly presented. Each radiogram is taken by four kinds of focal spot sizes. Characteristics of each observer and each group can be shown quantitatively by calculated information values. In an evaluation of radiographic images, radiologic technologists attach importance to physical characteristics of radiograms, but doctors do not do so. They attach importance to morphological and morbid variations of objects. Consequently, radiologic technologists have a close correlation between physical evaluation and a psychological one of radiograms, and doctors have only a little correlation.
抄録全体を表示
-
菊地 峻, 新井 かほる, 内山 常男, 中谷 議一郎, 園田 辰夫, 平林 久枝
原稿種別: 本文
1981 年 37 巻 6 号 p.
755-759
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
The lens of the eye is one of the radiosensitive critical organs. We must set up the radiation treatment planning to protect it as little as posible in the reduction of the dosage of the eye, not only benigh tumor but also malignant tumor. In our study, We have evaluated the technique of the radiation in the shallow lesion tumor arround the lens, such as conjunctival tumor. We can reduce the dosage of the lens and cornea 100% to less than 10% using with 2mm lead shield in thick in the treatment 6MeV electron beam. We found this technique is very usefull and effective in clinical radiation treatment planning.
抄録全体を表示
-
加藤 秀起, 河合 保
原稿種別: 本文
1981 年 37 巻 6 号 p.
760-765
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
The correction factor for the hollow out irradiation technique is usually calculated as a magnitude of dose reduction at the center of rotation with respect to primary radiation. This correction factor, which had taken account of scattered radiation, was calculated from the ratio of two average TARs with and without the hollow out absorber, and its scattered radiation component was distinguished from its primary radiation component to be analyzed. The magnitude of dose reduction rate with respect to the scattered radiation component was much the same to that with respect to the primary radiation component. Consequntly, the correction factor, which had taken account of scattered radiation, showed good agreement with the correction factor with respect to primary radiation only.
抄録全体を表示
-
山田 久夫, 佐々木 幹人
原稿種別: 本文
1981 年 37 巻 6 号 p.
766-772
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
An analysis was made of the geometric relation between stero-radiographing system and its observation one which has an effect on the imaging in the diagnostic stereography. (1) In stereography with magnified X-rays in which the magnification ratio of images on X and Y axis is different from the one on Z axis a kind of image distortion is inevitable. (2) Stereographing system under a certain appropriate condition can produce an image with equal magnification ratio of one on X, Y and also Z giving life-size without distortion. (3) As discribed above, a magnified stereographic image accompanies a distortion. However, a magnified stereographic image will be perceived if the image on the retina is enlarged, which can be obtained by shortening the visual distance thus widening the visual angle.
抄録全体を表示
-
越智 保, 上野山 文男, 白井 明子, 宇山 茂樹
原稿種別: 本文
1981 年 37 巻 6 号 p.
773-779
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
The content rate of scattered radiation is affected by tube voltage, object thickness, size of radiation field and with or without grid. We tried to formalize the relationship between the content rate and them. As changed the tube voltage, object thickness, radiation field and grid ratio, radiography varies in its film density, then we calculated the content rate of scattered radiation, and led two approximate equations by the method of multiple regression analysis. One of the equations was computed by using real value X of explaining variables, another by using root value √<X> except the explaining variable of tube voltage. As a result, the latter had better accuracy. Appling this approximate equation, when each explaining variable is within the boundary area, error is not over 10 percent, almost errors within 5 percent.
抄録全体を表示
-
高坂 唯子
原稿種別: 本文
1981 年 37 巻 6 号 p.
780-785
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Measurement of prostatic acid phosphatase (PAP) concentration is useful for the diagnosis and treatment of prostatic cancer. Fundamental studies of measurement of PAP concentration by radioimmunoassay were performed and values determined by three commercially available kits were compared, those are, PAP EIKEN RIA Kit (E kit), RIA Quant P.A.P. (M kit) and GammaDab PAP RIA Kit (C kit). Upper limits of normal PAP concentration were 3 ng/ml by E and M kits and 2 ng/ml by C kits, respectively. The reproducibility and the recovery studies of three kits were satisfactory. However, dilution curve of some patients was not strait. PAP concentration of 27 patients measured by three kits were correlated well to each other, but the discrepancy of values was noticed in high PAP concentrations. PAP concentration measured by RIA is more reliable than that by enzyme immunoassay. When keeping serum samples, the effect of time, temperature and frreze and thawing on PAP values was obvious. It is recomended that serum is separated at 4℃ as soon as possible after collecting blood and kept frozen until use.
抄録全体を表示
-
山口 尚二郎
原稿種別: 本文
1981 年 37 巻 6 号 p.
786-790
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Medical X-ray equipment brings about radiological, electrical and mechanical dangers to the patient and the operator. In order to produce the equipment free from danger, technical consideration especially from the standpoint of human engineering and safety engineering is necessary. Fundamental methods used in the design of medical X-ray equipment and several concrete examples of these methods are introduced in this paper.
抄録全体を表示
-
池田 善雄
原稿種別: 本文
1981 年 37 巻 6 号 p.
791-794
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Improvements were intended with a radiographic system for mass stomach screening by incorporating in its design the human-engineering concept for better safety, operability, effectiveness and serviceability particularly with the patient table which requires frequent contacts with the human beings such as examinees and operators.
抄録全体を表示
-
今井 健
原稿種別: 本文
1981 年 37 巻 6 号 p.
795-799
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
Several important points of the designing based on human engineering are described which are applied to improve information flow between an operator and a patient through an appliance in the case of a remotecontrolled diagnostic X-ray system which is the most widely used one in Japan. First, the importance of the systematic layout is presented. Next, several applications for the diagnostic table are explained such as foolproof provisions, soft-start and soft-stop movements of tabletop tilting, and reducing method of noise and vibration for getting rid of tension from the patient. Then, adequate style designing of control desk and efficient configuration of control devices on it are presented.
抄録全体を表示
-
森 定義
原稿種別: 本文
1981 年 37 巻 6 号 p.
800-807
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
In World War II, a new branch of learning human engineering was appeared in the U.S.A. mainly. The purpose of this learning is to heighten the efficiency of man-machine system and it is also desirable to be given the X-ray control desk, a thoughtful consideration. For this reason, radiological technologist should learn the outline of human engineering and comprehend the relation between human engineering and design of control desk. In this respect I introduced the dimension of control desk, design of controller and indicator in relation with human body dimension of radiological technologist. First, in the design of apparatus, it is reasonable to adopt the cumulative distribution in stead of mean values of human body dimension because the mean values would be cause of inadequacy to the majority of operator. Second, I reported about the fundamental items e.g. the display of controller and indicator recommended from the point of view of human engineering. Up to now the radiological technologists were intended to take a serious view of performance of X-ray apparatus only, but hereafter, we think, it is also important to induce the thought of human engineering in the design of X-ray apparatus.
抄録全体を表示
-
中西 省三
原稿種別: 本文
1981 年 37 巻 6 号 p.
808-813
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
In case of planning any medical X-ray system, we must consider the factors like capability, operation and safety. The safety and operation arise from human character. Therefore human engineering must be investigated and the harmony between the machine and the operater should be maintained, property and sufficiently.
抄録全体を表示
-
藤間 英雄
原稿種別: 本文
1981 年 37 巻 6 号 p.
814-824
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
There have been remarkable progress in the area of X-ray diagnosis technology in recent years. However, there have been some cases of accident. Such accidents included those due to defective apparatus such as defects in apparatus and poor safety system, those caused by incorrect handling of appratus by radiologic technologist, and those originating in a poor surrounding condition or bad management of apparatus. In this report investgated into following subjects. 1. Analysis of radiographic error. 2. Analysis of failure in medical X-ray systems.
抄録全体を表示
-
上野 晴樹
原稿種別: 本文
1981 年 37 巻 6 号 p.
825-830
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
The concept of applying Human Engineering to the safety design of medical appatatuses and systems is discussed. It has been required to apply the safety engineering to medicine in order to meet the requirements from sophisticated man-machine systematizations in a hospital. The basic elements of the systems engineering in terms of safety design include 1) to treat the objects as a total system, 2) to apply the most appropriate measures with limited resources. From this point of view it is useful to consider the system's lifecycle, i.e., planning-designing-producing-installing-managing-replacing cycle. The most appropriate safety measures have to be applied to each stage of the cycle. Human Engineering based measures such as appropriate man-machine interface design are the key points to achieve the concept.
抄録全体を表示
-
黒江 篤, 橋口 広行, 釘本 孝, 渡辺 敏幸, 名田 克彦, 藤沢 健次
原稿種別: 本文
1981 年 37 巻 6 号 p.
831-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
堀尾 重治, 岡部 健吾, 高橋 伸一, 神谷 靖治, 京田 邦彰, 佐藤 典成, 白石 承勲
原稿種別: 本文
1981 年 37 巻 6 号 p.
831-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
寺門 秀司, 高草 木浩, 縫島 修, 鈴木 豊, 伊藤 えい子, 市川 博彦, 増淵 伸春
原稿種別: 本文
1981 年 37 巻 6 号 p.
832-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
米岡 敏雄, 長畑 弘
原稿種別: 本文
1981 年 37 巻 6 号 p.
832-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
佐野 芳知, 針替 栄, 中畑 和朗, 小川 敬寿
原稿種別: 本文
1981 年 37 巻 6 号 p.
832-833
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
伊藤 謙助, 嶋 孝治
原稿種別: 本文
1981 年 37 巻 6 号 p.
833-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
岩佐 彰, 沢田 道人, 後藤 良蔵
原稿種別: 本文
1981 年 37 巻 6 号 p.
833-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
大貫 一信, 山岸 豊, 小笠原 哲, 大棒 秀一, 杉尾 敏憲, 小島 廸子, 海老根 精二
原稿種別: 本文
1981 年 37 巻 6 号 p.
833-834
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
世古 勝彦
原稿種別: 本文
1981 年 37 巻 6 号 p.
834-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
谷越 修
原稿種別: 本文
1981 年 37 巻 6 号 p.
834-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
内藤 光利, 堀田 勝平, 梶原 和則, 岩根 戊, 安部 忠夫
原稿種別: 本文
1981 年 37 巻 6 号 p.
834-835
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
南 博, 望月 達己, 中川 順司
原稿種別: 本文
1981 年 37 巻 6 号 p.
835-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
坂本 真一, 大原 由起子, 坂手 敏明, 高橋 秀彰
原稿種別: 本文
1981 年 37 巻 6 号 p.
835-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
工藤 弘明, 畑川 政勝, 奥山 和夫, 細見 実
原稿種別: 本文
1981 年 37 巻 6 号 p.
835-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
木村 千明, 杉江 義男, 高橋 一広, 竹村 克人
原稿種別: 本文
1981 年 37 巻 6 号 p.
836-849
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
850-851
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
852-861
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
862-863
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
864-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 目次
1981 年 37 巻 6 号 p.
865-866
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 目次
1981 年 37 巻 6 号 p.
867-869
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
870-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 付録等
1981 年 37 巻 6 号 p.
871-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー
-
原稿種別: 表紙
1981 年 37 巻 6 号 p.
Cover18-
発行日: 1981/11/01
公開日: 2017/06/28
ジャーナル
フリー