日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
71 巻, 5 号
選択された号の論文の11件中1~11を表示しています
巻頭言
ノート
  • 笠井 洋平, 西原 貞光, 湯浅 将生, 鹿重 俊哉, 松浦 貴明
    2015 年 71 巻 5 号 p. 423-427
    発行日: 2015年
    公開日: 2015/05/20
    ジャーナル フリー
    A short length scatterer is adopted to measure the X-ray spectrum of computed tomography (CT) equipment with a wide irradiation field in the body axis direction. The purpose of this study is to compare X-ray spectra measured using different length scatterers and determine the most appropriate length for the scatterer. 320-slice CT equipment (Aquilion ONE) was used in this study. Circular carbonrods (3 cm diameter) with five different lengths (1–16 cm) were used as scatterers. The effect of the beam hardening phenomenon from different length carbon rods was evaluated according to the effective energy. The measurement accuracy for photon information was also evaluated based on the photon count corresponding to the characteristic X-ray. As a result, the beam hardening effect was scarcely observed when the 1 cm long scatterer was used, and the number of the photons measured for the characteristic X-ray was the most. Therefore, it was concluded that the 1 cm long circular carbon rod scatterer was the most suitable.
臨床技術
  • 中谷 香澄, 福西 康修
    2015 年 71 巻 5 号 p. 428-438
    発行日: 2015年
    公開日: 2015/05/20
    ジャーナル フリー
    Computed tomographic angiography (CTA) has been used recently for the evaluation of intracerebral aneurysms, but it is difficult to use this technique to visualize aneurysms near the base of the skull because of the presence of bone. So, subtracted CTA has been used to separate vessels from bony structures. However, we see some misregistration when using subtraction method because of the patient moving, the disaccord of the X-ray tube orbit between the mask image and the live image, the expanding focus, and the bed bending. So, attentioning the difference of bone CT number in any tube voltages, we examined to make the image containing less misregistration by changing the tube voltage of mask image. Making a sham blood vessel, we examined the bone misregistration, the blood vessel volume, and the smoothness when changing the tube voltages of mask images. Comparing with 120 kV, as the tube voltage of the mask image was 80 kV, the bone misregistration decreased significantly, however the blood vessel volume decreased. As for the tube voltage of 100 kV, the bone misregistration decreased significantly, and the blood vessel volume and the smoothness were not significantly different so we could get coordinative image of 120 kV. When the tube voltage of the mask image becomes lower than that of the live image and the effective energy becomes different, the effect of misregistration is less. This method deals with changing the tube voltage only. So, it may be easy to make volume rendering (VR) image and this method may be used in every facility.
資料
第42回秋季学術大会教育講演
教育講座―モンテカルロシミュレーションの放射線技術への利用―
基礎講座―脳の病気:診断から治療まで―
標準・規格委員会だより
国際研究集会派遣報告
JIRAトピックス