Japanese Journal of Radiological Technology
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
Volume 82, Issue 11
Displaying 1-7 of 7 articles from this issue
Original
  • Shinya Misawa, Junji Mochizuki
    2026Volume 82Issue 11 Article ID: 26-1695
    Published: 2026
    Released on J-STAGE: October 07, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: This study aimed to determine the optimal tube voltage and number of image averages for late iodine enhancement CT (LIE-CT) using physical image quality metrics. Methods: A water phantom containing diluted contrast media (approx. 30 HU at 120 kV) was scanned under ECG gating. Tube voltage was varied (70, 80, 100, and 120 kV), and image averaging was performed for 1 to 6 scans, based on a CTDIvol of 3.7 mGy per scan. CT numbers, standard deviation (SD), and noise power spectrum (NPS) were measured for each image. The low-contrast object-specific CNR (CNRLO) was calculated, and the figure of merit (FOM) was derived using the size-specific dose estimate (SSDE) at a spatial frequency of 0.1 cycles/mm. Results: CNRLO increased as tube voltage decreased and the number of averages increased, reaching a maximum at 70 kV. CT numbers and NPS also showed an upward trend with decreasing tube voltage. In contrast, the FOM peaked at 3 to 4 averages across all tube voltages and declined from the 5th scan onward due to decreased dose efficiency. Conclusion: For LIE-CT, 4-scan image averaging at 70 kV can be a useful protocol balancing image quality and radiation dose.

  • Hiromu Nonaka, Noriyuki Nagami, Keiichi Ohira, Kenta Inoue, Osamu Toga ...
    2026Volume 82Issue 11 Article ID: 26-1657
    Published: 2026
    Released on J-STAGE: October 08, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: Average intensity projection (AIP) is an image generation method obtained by averaging the images of each phase of 4D-CT. This study aimed to evaluate tumor respiratory motion and, using the union of contours from all 4D-CT phases (4DTotal) as the reference, to compare contour agreement among contours derived from 3D-CT, maximum intensity projection (MIP), and AIP images. In addition, dose metrics in treatment planning were evaluated to explore the dosimetric impact of contour differences among the image sets. Methods: Eight patients who underwent lung stereotactic body radiotherapy (SBRT) at our institution were included. Tumor motion was first characterized from centroid positions across ten 4D-CT phases. Next, 4DTotal was generated by taking the union of the contours extracted from each phase. Finally, contours from 4D-CT AIP, 4D-CT MIP, and slow-scan 3D-CT (3DSlow) were compared with 4DTotal using volume difference, centroid difference, Dice similarity coefficient (DSC), Jaccard index, 95th percentile Hausdorff distance (HD95), mean surface distance (MSD), and surface Dice similarity coefficient with a 2-mm tolerance. In addition, treatment plans were generated using each contour set, and Dmax (cGy), lung V5 (%), lung V20 (%), conformity index (CI), and homogeneity index (HI) were compared. Results: Tumor motion was greatest in the inferior–superior direction and was generally multi-directional. For AIP, centroid difference was ≤1 mm in each direction (LR/AP/IS), and the median values of DSC, Jaccard index, HD95, MSD, and surface DSC (2 mm) were 0.831, 0.711, 1.707 mm, 0.451 mm, and 0.981, respectively, showing good geometric agreement with 4DTotal. No significant differences were observed between AIP and MIP, whereas both AIP and MIP showed better agreement than 3DSlow. In the dose evaluation, no significant overall differences were observed for any metric among the four contour sets. In the exploratory analysis, paired comparisons using 4DTotal as the reference showed a directional decrease in lung V20 for AIP and a directional increase in CI for MIP. These findings should not be interpreted as definitive conclusions, but rather as results of an exploratory analysis based on a limited number of cases. Conclusion: The AIP method showed good geometric approximation to 4DTotal and may represent the time-dependent displacement of tumor position within a single dataset. In this limited exploratory analysis, no major disadvantage in treatment planning was observed. However, the observed changes in dose metrics, including lung V20, should not be interpreted as evidence of dosimetric superiority and require further validation. Because of uncertainty in the reference contour and the limited number of cases, further investigation is needed to clarify its clinical significance.

  • Daiki Horita, Takayuki Nomura, Hiroaki Neki, Satoshi Goshima
    2026Volume 82Issue 11 Article ID: 26-1687
    Published: 2026
    Released on J-STAGE: October 14, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: The aim of this study was to clarify the composition of patient radiation dose in Woven EndoBridge embolization (WEB) and to compare it with stent-assisted coiling (SAC). Methods: Fifteen patients in the WEB group and 15 patients in the SAC group were retrospectively analyzed. Total air kerma at the reference point (Ka,r), fluoroscopy air kerma (Fl-Ka,r), stationary air kerma (St-Ka,r), rotational air kerma (Ro-Ka,r), air kerma-area product (PKA), fluoroscopy time, number of acquisitions, procedure time, and peak skin dose (PSD) were compared between the two groups. Results: Fl-Ka,r, fluoroscopy time, procedure time, and PSD were significantly lower in the WEB group than in the SAC group. In contrast, Ro-Ka,r was higher in the WEB group. The proportion of Ro-Ka,r to Ka,r was 46% in the WEB group and 26% in the SAC group. Conclusion: Compared with SAC, WEB was associated with lower Fl-Ka,r and shorter procedure time, whereas the contribution of Ro-Ka,r was greater. Therefore, radiation dose management in WEB should not rely solely on Ka,r; rather, it is important to understand each dose component individually.

  • Kenji Yasue, Atsushi Urikura, Koichi Hanada, Hiraku Fuse
    2026Volume 82Issue 11 Article ID: 26-1692
    Published: 2026
    Released on J-STAGE: October 17, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: This study aimed to quantify the effect of measurement duration on subject thickness accuracy using an RGB-D camera at a source-to-image distance (SID) of 200 cm for chest radiography and to evaluate the accuracy of entrance surface dose (ESD) estimation based on 1-s measurements. Methods: A chest radiography phantom was evaluated at subject thicknesses of 20, 25, 30, and 35 cm. Subject thickness was measured five times at measurement durations of 1, 5, and 10 s and compared with caliper measurements. ESD estimated from the mean subject thickness obtained over 1 s was compared with the reference ESD calculated from the caliper-based thickness. Results: The maximum subject thickness error was 0.48 cm, the maximum relative error was +1.4%, and the maximum standard deviation was 0.12 cm. No significant differences among measurement durations were found at 20, 25, or 30 cm. At 35 cm, an overall difference was found, but no pairwise difference was significant after adjustment for multiple comparisons. The maximum relative error in ESD estimation was +0.6% at 35 cm. Conclusion: Under static phantom conditions at an SID of 200 cm, subject thickness measurements obtained over 1 s and the resulting ESD estimates were close to the reference values. These findings support further evaluation of short-duration RGB-D measurements for chest radiography.

  • Masato Takahashi, Hiraku Fuse, Koichi Hanada, Manamu Kimura, Kenji Yas ...
    2026Volume 82Issue 11 Article ID: 26-1705
    Published: 2026
    Released on J-STAGE: October 17, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: To develop a click-prompt-style semi-automatic defect segmentation method using Segment Anything Model 2 (SAM2) with Low-Rank Adaptation (LoRA) for fluoroscopic images of lead aprons and to evaluate its quantitative performance and usefulness. Methods: Twenty-four fluoroscopic images acquired from 19 lead aprons were divided into training/validation (n=14) and test datasets (n=10). Two radiological technologists independently annotated the test images and established Consensus GT masks after reviewing discrepancies. Four radiological technologists performed manual and click-prompt-based segmentation using SAM2 Original and SAM2-LoRA (r=8, 16, and 32). All methods were evaluated against the Consensus GT. Results: Inter-annotator agreement between the two independent GT masks was ICC(2,1)=0.982 for area, with a Dice coefficient of 0.802 and IoU of 0.674. Mean Dice coefficients against the Consensus GT were 0.708 for manual segmentation, 0.426 for SAM2 Original, and 0.752, 0.774, and 0.759 for SAM2-LoRA with r=8, 16, and 32, respectively. The r=16 setting showed the smallest mean absolute area error among the models (69.7 mm2). Conclusion: Under the conditions of this small single-center study, click-prompt-based SAM2-LoRA may support measurement of candidate defect areas in fluoroscopic images of lead aprons. External validation is required before use for automated rejection decisions.

  • Mizuki Kakisako, Ryo Watanabe, Makoto Fujiwara, Kenta Maruyama
    2026Volume 82Issue 11 Article ID: 26-1696
    Published: 2026
    Released on J-STAGE: October 17, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: In coronary CT angiography, we compared the profile characteristics and visual assessment of coronary stents between hybrid iterative reconstruction combined with a sharpening filter (S-HIR) and deep learning reconstruction (DLR). Methods: We scanned a performance evaluation phantom and a custom-made phantom incorporating a coronary artery stent with an inner diameter of 3.5 mm. Images were reconstructed using DLR, hybrid iterative reconstruction (HIR), and S-HIR of three sharpening strengths. We evaluated task-based transfer function (TTF) values, the maximum CT number of the stent struts, the error rate of the stent lumen diameter, rectangularity, and visual assessment performed by nine radiological technologists using Scheffé’s paired comparison method. Results: In S-HIR, TTF values and rectangularity increased, while the error rate decreased with increasing sharpening strength. Visual assessment revealed no significant difference between sharpening medium filter+HIR (SM-HIR) and DLR. In contrast, sharpening high filter+HIR (SH-HIR) resulted in an excessive increase in the maximum CT number of the stent struts, and visual assessment scores decreased. Conclusion: The S-HIR method newly proposed in this study altered the profile characteristics of coronary artery stents and improved their visibility in coronary CT angiography under phantom conditions. In particular, SM-HIR showed no statistically significant difference from DLR in visual assessment and could serve as a useful technique for improving coronary stent visibility in CT systems without DLR.

  • Noriyuki Toyoshima, Yasuo Takatsu, Wataru Kawamata, Hideto Toyoshima
    2026Volume 82Issue 11 Article ID: 26-1704
    Published: 2026
    Released on J-STAGE: October 28, 2026
    JOURNAL OPEN ACCESS FULL-TEXT HTML

    Purpose: Evaluation of glioblastoma (GBM) with weak contrast enhancement and small metastatic brain tumors can be challenging. This study aimed to optimize imaging parameters for three-dimensional phase-sensitive inversion recovery (3D-PSIR) and compare its performance with a conventional method using a phantom experiment. Methods: MRI was performed using a 1.5-T Achieva system (Philips, Best, the Netherlands). Phantoms were prepared to simulate white matter, gray matter, and low-level gadolinium contrast enhancement. PSIR was combined with a 3D T1 turbo field echo sequence. The TFE factor, shot interval (SI), and TI delay were varied, and the contrast-to-noise ratio (CNR) was evaluated. Results: The TFE factor of 10 yielded high CNR values. The CNR tended to increase with increasing shot interval, although the rate of increase became smaller at shot intervals of 2000 ms or longer. High CNR values were also obtained at TI delay times of 600–1000 ms. Compared with conventional 3D fast field echo (3D-FFE), 3D-PSIR achieved more than twice the CNR. Conclusion: Under appropriate imaging conditions, 3D-PSIR demonstrated higher CNR than conventional 3D-FFE in a phantom simulating subtle contrast enhancement. These findings may provide fundamental evidence for the potential clinical application of 3D-PSIR in improving the visualization of brain tumors with subtle contrast enhancement.