CHROMATOGRAPHY
Online ISSN : 1348-3315
Print ISSN : 1342-8284
ISSN-L : 1342-8284
Current issue
Displaying 1-6 of 6 articles from this issue
Original
  • Yoko NUNOME, Yumeno SHINYASHIKI, Sachika MANTANI, Hinano ITO, Kenji KO ...
    2026Volume 47Issue 3 Pages 131-141
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: June 10, 2026
    JOURNAL FREE ACCESS

    Structural characterization of volatile terpenoids, including sesquiterpene isomers represented by the chemical components of Cannabis sativa L. remains a significant challenge in forensic drug detection. In this study, a novel classification principle for these compounds is presented using direct current pulse discharge soft plasma ionization mass spectrometry. By modulating the discharge duty ratio (D), a method has been developed to actively control the transition between maintaining molecular-related information for individual characterization and generating functional-group-specific common indicators. At a low D (5 %), fragmentation was significantly suppressed compared to that at a high D (50 %), leading to the stable formation of molecular-related ions for oxygenated sesquiterpenes such as farnesol. In contrast, at D = 50 %, a characteristic fragment at m/z 117 ([C5H9 + O3]+) was observed as the base peak specifically for oxygenated sesquiterpenes. This phenomenon is attributed to a unique fragmentation pathway (Path A), reported here for the first time to our knowledge, involving the addition of neutral ozone—whose density is maximized under a reduced pressure of 2.5 kPa—to a hydroxy-initiated allyl cation fragment. Our analysis achieved high sensitivity with limits of detection ranging from 0.2 ppbv to 5.3 ppbv. This remarkable sensitivity enabled the quantitative evaluation of low-abundance natural isotopic ratios, facilitating the visual and statistical differentiation of oxygenated species from hydrocarbons like longifolene through a two-dimensional isotope correlation map. This approach, when combined with chromatography, would provide a practical classification scheme that allows for the reliable characterization of specific chemical structures using a simplified instrumental setup.

    Download PDF (1624K)
  • Aoi TANIGUCHI, Kenichi KAWANO, Kenichi NAGASE
    2026Volume 47Issue 3 Pages 143-151
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: July 16, 2026
    JOURNAL FREE ACCESS

    Temperature-responsive chromatography using poly(N-isopropylacrylamide) (PNIPAAm) has been extensively investigated as a functional chromatographic system. Because the retention behavior of analytes can be modulated by adjusting the column temperature, aqueous mobile phases without organic solvents were used. Thus, few studies have been conducted on the effects of adding organic solvents, such as methanol, to the mobile phase. In this study, methanol was introduced into the aqueous mobile phase to examine its influence on the elution behavior of steroid compounds. The results showed that increasing the methanol content reduced the retention times of the steroids because of their enhanced solubility in the mobile phase. However, the separation efficiency was strongly dependent on the methanol concentration. At methanol concentrations of 5 % and 10 %, shorter retention times were achieved while maintaining satisfactory steroid resolution. In contrast, methanol concentrations of 15 % and 20 % resulted in a noticeable decline in steroid resolution. These findings indicate that methanol addition can be an effective strategy for controlling analyte retention time in temperature-responsive chromatography, provided that the methanol content is maintained at 10 % or lower to preserve adequate separation performance.

    Download PDF (2858K)
  • Kohei KAWABATA, Manaka KONO, Yoko NUNOME, Shiori AKIMOTO, Masanori INA ...
    2026Volume 47Issue 3 Pages 153-158
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: July 22, 2026
    JOURNAL FREE ACCESS

    Haloperidol (HP) is a typical antipsychotic drug, which is used for the treatment of psychosis including schizophrenia. In this study, HP photodegradation was evaluated to clarify the photostability of HP tablets because the photodegradation might affect both the quality and the quantity. For the better understanding of photochemical properties of HP, firstly, residual amounts of UV-irradiated HP samples were monitored using a high-performance liquid chromatography (HPLC) system. HP was photodegraded along with the generation of several photoproducts, so structural elucidation of them was carried out based on liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The authors succeeded in elucidating the chemical structure of one photoproduct and its generation pathway. Furthermore, in silico toxicity prediction was performed to predict the toxicological potencies of the photoproduct. Finally, the photostability evaluation of HP tablets and its altered forms (powders and suspensions) were evaluated.

    Download PDF (1237K)
  • Aoi TANIGUCHI, Kenichi KAWANO, Kenichi NAGASE
    2026Volume 47Issue 3 Pages 159-167
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: July 16, 2026
    JOURNAL FREE ACCESS

    Poly(N-isopropylacrylamide) (PNIPAAm) brush-modified bead-packed columns have been investigated as temperature-responsive stationary phases. However, these columns often exhibit long analyte retention times. In this study, methanol or ethanol was added to the mobile phase to investigate its effect on analyte elution behavior in a PNIPAAm brush-modified bead-packed column. The phase transition temperature of PNIPAAm decreased with the addition of methanol or ethanol, due to enhanced dehydration of the polymer. The temperature-dependent elution of steroids was examined using a PNIPAAm brush-modified silica bead-packed column with aqueous mobile phases containing methanol or ethanol. The retention times of steroids decreased with the addition of these organic solvents, likely because of increased solubility in the mobile phase. Ethanol reduced retention times more effectively than methanol. These results demonstrate that the addition of methanol or ethanol to the mobile phase is an effective approach for controlling analyte retention in PNIPAAm brush-modified silica bead-packed columns.

    Download PDF (2590K)
  • Serina ICHIKI, Koki NAKAGAMI, Ayano TAKADA, Ikuo UETA, Yoshihiro SAITO
    2026Volume 47Issue 3 Pages 169-175
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: August 19, 2026
    JOURNAL FREE ACCESS

    A needle-type sample preparation device prepared by packing a bundle of polyimide filaments into a specially-designed needle has been developed for the subsequent gas chromatographic (GC) analysis of formaldehyde (FA) in air samples. In this study, FA was derivatized using n-octylamine as the derivatization reagent coated on the surface of polyimide filaments packed in the needle device, and the derivative was determined by a flame ionization detector (FID), which is one of the most popular detectors in GC. Under the optimal condition for the sample preparation, gaseous FA was successfully derivatized and the FID signal intensity was significantly improved. Calibration curve for FA showed a linear relationship in the range of 0.05-0.30 ppmv with a high correlation coefficient (r2 = 0.955). The relative standard deviation for the obtained peak areas within the measured concentration range was 6.0 % or less. The limit of detection and limit of quantification values were 0.003 ppmv and 0.011 ppmv, respectively.

    Download PDF (1019K)
Short communications
  • Takumi NARITA, Fuwari SHISHIKURA, Hiroki MATSUOKA, Rinoha MASUZAWA, Yu ...
    2026Volume 47Issue 3 Pages 177-181
    Published: October 20, 2026
    Released on J-STAGE: November 04, 2026
    Advance online publication: June 29, 2026
    JOURNAL FREE ACCESS

    It has been suggested that bile acids (BAs) are involved in the pathogenesis and worsening of hepatic encephalopathy (HE). In this study, the serum taurine-conjugated BA (T-BA) profile in the bile duct-ligated (BDL) rat, an HE model, was determined by liquid chromatography (LC)/electrospray ionization-tandem mass spectrometry. Under the optimized LC conditions using an Ascentis Express 90 Å C18 column, a satisfactory separation was achieved for the isomeric T-BAs. The deuterium-labeled T-BAs were synthesized and used as the internal standards. The serum analysis revealed that in the BDL rats, the levels of primary T-BAs, i.e., tauro-α-muricholic acid, tauro-β-muricholic acid, taurocholic acid and taurochenodeoxycholic acid, increased 55–590-fold as high as those in the normal rats. These very high concentrations of the serum T-BAs might lead to the breakdown of the blood-brain barrier integrity, which is thought to be one of the possible mechanisms of the pathogenesis and worsening of HE.

    Download PDF (840K)
feedback
Top