太陽エネルギー
Online ISSN : 2433-5592
Print ISSN : 0388-9564
最新号
選択された号の論文の5件中1~5を表示しています
研究論文
  • 平野 敬祐, 松尾 廣伸
    2026 年52 巻5 号 p. 45-51
    発行日: 2026/09/30
    公開日: 2026/10/14
    ジャーナル フリー

    In this study, electrical discharge weeding, a non-chemical control method, was applied to experimentally cultivated arugula (Eruca vesicaria subsp. sativa) and the invasive alien species Alternanthera philoxeroides (alligator weed). The effects of applied voltage, discharge duration, and soil water content were evaluated through visual damage assessment, analysis of variance, measurements of electrical resistance changes. In arugula, applied voltage was identified as the dominant factor, whereas the effect of discharge duration was relatively small. In addition, an optimal soil water condition that maximized tissue damage was determined. Tissue damage corresponded to reductions in electrical resistance, exhibiting a threshold-like response in which damage scores increased sharply once the resistance decrease exceeded a certain level. In A. philoxeroides, all individuals (10/10) were killed under the 15 kV–30 s condition; however, the effects on underground tissues were not clearly determined, indicating the difficulty of controlling underground organs using electrical discharge weeding.

  • 岡﨑 翔太, 髙橋 明子, 重信 颯人, 伊藤 雅一, 足立 隆之, 村牧 義之
    2026 年52 巻5 号 p. 53-60
    発行日: 2026/09/30
    公開日: 2026/10/14
    ジャーナル フリー

    In recent years, increasing electricity demand due to abnormal weather and the aging of thermal power generators have made it difficult to meet peak demand. As a solution, energy shifting using hydrogen to level annual demand has gained attention. This paper proposes a long-term operational planning method using a hydrogen energy storage system (HESS) for a large-scale system model covering the Hokuriku area. Annual demand trends were leveled based on historical demand data and output of the HESS was determined accordingly. By subsequently optimizing the start–stop schedules of thermal power plants, the demand fluctuation range was reduced from 3,350 MW to 2,874 MW. This resulted in the elimination of two thermal power plants and achieved annual cost savings of 2.062 billion yen. Although the introduction cost of the HESS remains high, this method demonstrates the potential to reduce the rated capacity of thermal power plants, suggesting that it could be an effective strategy for achieving a future carbon-neutral society.

  • 山下 諄, 桶 真一郎, 大竹 秀明
    2026 年52 巻5 号 p. 61-68
    発行日: 2026/09/30
    公開日: 2026/10/14
    ジャーナル フリー

    In photovoltaic (PV) systems, installing PV arrays whose rated capacity exceeds that of the power conditioning system (PCS) is referred to as DC-to-AC oversizing (inverter overloading). This study investigates the interaction between oversizing and spatial smoothing in large-scale PV power generation. Using estimated actual (reconstructed) and forecasted PV power data from 105 sites in the Kanto region of Japan, the variability characteristics and forecast errors of aggregated PV power were evaluated for inverter loading ratios (ILRs) ranging from 1.0 to 3.0. Results indicate that oversizing locally increases variability through clipping and enhanced ramp rates, whereas spatial aggregation of geographically dispersed PV power mitigates fluctuations by reducing the duration of clipping and decreasing the frequency of ramp occurrences. The root mean square error (RMSE) decreases with increasing aggregation radius, with significant improvement observed up to approximately 50 km and limited gains beyond this range. A normalized RMSE variation index reveals that the trade-off between oversizing-induced variability and spatial smoothing is strongly governed by spatial scale.

技術報告
feedback
Top