  • 赤塚 孝雄, Takashi Isobe
    1974 年 4 巻 2 号 p. 35-55
    発行日: 1974年
    公開日: 2012/08/27
    ジャーナル フリー
    胃のX線写真,特に充盈像の識別はその辺縁の自然な形からのずれの判定によって行われている.そこでX線写真から胃の像を忠実に抽出し,定量的に記述するとともに辺緑の特徴を抽出する方法について考察を進めようとするのがここでの目的である.読取り走査を目的に応じて計算機の制御のもとに繰返し行える系を構成することによって,小容量の計算機でX線写真の処理を行うことができる.
  • 内田 勝, 稲津 博, 猪ケ倉 政盛
    1974 年 4 巻 2 号 p. 56-68
    発行日: 1974年
    公開日: 2012/08/27
    ジャーナル フリー
    At present, the demensiona of focal spot is determined by means of X-ray pin-hole cameras and resolution method. But this method is not practical for routine work. The magnified radiographic image of star test pattern is a useful determination of effective focal spot size. We investigated the change of effective focal spot size by means of the star test pattern method. In the result of experiment, the effective focal spot size is enlarged by increasing milliamperage. But this phenomenon has been expected. The rate of enlargement is different from each Xray tube. This phenomenon is caused by convergence effect of thermoelectron. The effective focal spot size is present the minimum value by milliamperage. When the radiographic image is maked, the milliamperage value must be chosen a minimum effective focal spot size.
  • 内田 勝, 稲津 博
    1974 年 4 巻 2 号 p. 69-74
    発行日: 1974年
    公開日: 2012/08/27
    ジャーナル フリー
    In the radiographic system, scattered radiations from object make the image quality poor. As clean-up equipment, X-ray grids and collimator are generally used. The efficiency of collimator had been geometrically evaluated concerning extra focal radiation and penumbra. As to the influence of scattered radiations on the image quality some more quantitativeevaluation is necessary.
    In this paper, we tried to show the clean-up effect of scattered radiations of collimator by means of the technique of Modulation Transfer Function (MTF).
    Let MTF of systems with collimator and without collimator be X(ω) and Y(ω)respectively. The MTF C(ω) of clean-up effect of scattered radiations by collimator is to be obtained by the Vol.4 No.2 1974 69following Equation. C(ω)=X(ω)/Y(ω)
    Where C(ω) is changed by radiation fields.
    From the theory above mentioned, we studied about the MTFs of clean-up effect of scattered radiations on each radiation field of 10×10cm.,20×20cm. and 30×30cm.. As a phantom, we used acrilic board of 9cm. thick, and the conditions of exposure are 80kVp. and 100mA..
    The experimental results are shown in Figure 3. It is proper that the improvement of image in narrow radiation field is better than in wide one. If the clean-up effect of scattered radiations is evaluated by MTF, then the difference of result by mesurement method is solved, we can evaluate the clean-up effect quantitatively.
    This method is useful to the selection of the optimum combination of X-ray grid and radiation field, and these results are useful to the selection of equipments according to radiographic portions. The effective selection of equipments is useful to the reduction of patient exposures and the improvement of capability of diagnosis.
  • 竹中 栄一, 宮前 達也, 木下 幸次郎, 山口 奉頼
    1974 年 4 巻 2 号 p. 78-85
    発行日: 1974年
    公開日: 2012/08/27
    ジャーナル フリー
  • 佐藤 孝司
    1974 年 4 巻 2 号 p. 86-92
    発行日: 1974年
    公開日: 2012/08/27
    ジャーナル フリー
    診断用に使用されるX線のエネルギー分布は連続スベクトルを持つため,その線質の表示も複雑で各表示方法により異なった数値で示される.今回,診断用X線の線質の表示について各種の方法を比較検討した.