The measurement of leveling of bright copper plating from both low and high concentration baths such as CuSO
4⋅5H
2O 100g/
l, H
2SO
4 150g/
l and CuSO
4⋅5H
2O 200g/
l, H
2SO
4 50g/
l was carried by using Hull Cell test panel. Leveling of bright copper plating from the low concentration bath was found to be less than that from the high concentration bath at the high current density, however, low concentration bath gave the better leveling in the low current density region, and at high temperatures such as above 30°C. The brightener for copper sulfate bath was composed of thiourea derivative, dyestuffs and wetting agents. Neither the levering nor the bright copper plating was obtained from the bath in which each one or two components of the brightener were added. However, when three components of the bringhtener were used together in the bath, copper plating gave good leveling and brightness. The optimum concentration of these compoents for the low concentration copper sulfate bath was as follows; thiourea derivative (1% solution) 2-3m
l/l, dyestuffs (1% solution) 0.25-0.5m
l/l, and wetting agents (low polymer 1%, high polymer 0.1% solution) 1m
l/l.