This report show the study regarding the method which estimate specific water consumption for the purpose of architectonics. In this report, by using actual measurement data of water consumption per day, monthly water consumption is calculated. Additionally, examination about water specific water consumption that is calculated on the basis of the monthly water consumption is proper value or not is done.
抄録全体を表示
-
柳村 暁, 小坂 信二
原稿種別: 本文
セッションID: A-2
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Comparison of the water load calculating method and the heat load calculating method was performed. The table of Water Load Calculation was created.
抄録全体を表示
-
小坂 信二, 柳村 暁
原稿種別: 本文
セッションID: A-3
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
By the water load calculating method, hot-water load is also calculable if a factor is changed.. Comparison of water supply load and hot-water supply load was calculated. Moreover, the calculation of Storage Tank capacity is attained using the rate of load according to the hourly hot-water load rate. The rate of load is based on statistics data in many cases. The peak value of the rate of load by the building scale was investigated.
抄録全体を表示
-
越川 康夫, 村川 三郎, 高田 宏, 仲川 ゆり
原稿種別: 本文
セッションID: A-4
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We carried out the simulation of the instantaneous, the hourly and the daily water load every one hour from 4 o'clock until 24 o'clock by using the number of station toilet arrival people at the T station in Tokyo. The result of simulation is shown that the change in the waiting time due to the increase and decrease of the number of equipments is large, and the change in three kinds of loads doesn't have a large influence with the number of those.
抄録全体を表示
-
高田 宏, 村川 三郎, 西名 大作, 高橋 大輔
原稿種別: 本文
セッションID: A-5
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The purpose of this study is to obtain the basic data to the development of new calculating method for cold and hot water supply demands. The volumes of cold and hot water consumption measured by 1 minute or 20 second interval for 6 weeks at 7 restaurants were analyzed. In this paper, the results of measurement of daily cold and hot water consumptions were shown. And the relationships between daily water consumptions and number of customers were analyzed.
抄録全体を表示
-
高橋 大輔, 村川 三郎, 西名 大作, 高田 宏
原稿種別: 本文
セッションID: A-6
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The purpose of this study is to obtain the basic data to the development of new calculating method for cold and hot water supply demands. The volumes of cold and hot water consumption measured by 1 minute or 20 second interval for 6 weeks at 7 restaurants were analyzed. In this paper, the results of measurement of cold and hot water consumption for one minute and one hour were shown.
抄録全体を表示
-
山根 祐子, 村川 三郎, 西名 大作, 高田 宏
原稿種別: 本文
セッションID: A-7
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The purpose of this study is to develop a calculating method for cold and hot water consumption in office building. This paper shows the state of office worker's presence and the characteristics of water usage in the hot-water service rooms by the questionnaire investigation and measurement in the D building. Under the analysis of results, we set up the calculating model. Furthermore, we carried out the simulation for calculating the time series loads. By comparing the values of measurement and simulation, the applicability of calculating method for hot-water service room in office building is verified.
抄録全体を表示
-
嶌田 成二, 小川 正晃, 泉 裕三
原稿種別: 本文
セッションID: A-8
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We have quite a few data which measured the amount of water consumption of hot spa institution. This report analyzes the result which measured the amount of water and hot water consumption in a hot spa institution and proposes the design water and hot water consumption for a design of hot spa facilities.
抄録全体を表示
-
矢作 正博
原稿種別: 本文
セッションID: A-9
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This paper describes design methods to optimize capacity of hot water supply equipments. Hot water load survey was carried out at three hotels in Tokyo. In addition, questionnaires were administered about bathing through the Internet to considerable numbers of people. Based on the results of load survey and questionnaires, optimized capacity of water heaters and hot water tanks were simulated. The required capacity based on the simulation showed a good coincidence with the result of the load survey.
抄録全体を表示
-
草刈 和俊, 小林 和幸, 濱中 香也子, 榊原 久介, 村橋 秀峰, 百瀬 忠幸
原稿種別: 本文
セッションID: A-10
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This paper deals with the load for hot water supply system. When we developed CO2 heat pump hot water heater, we measured amount of hot water use for each family. We analyze the trend of amount of hot water use on number of family, each season, time etc. Using these results, we will develop more suited CO2 heat pump hot water supply system for Japanese family.
抄録全体を表示
-
森 教子, 多田 裕貴, 森山 正和
原稿種別: 本文
セッションID: A-11
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In this paper, the energy consumption and the efficiency of high efficient equipment for hot water supply under the actual use condition were investigated at 4 detached houses in Kinki region. As a result, it is clarified the different ways of bathing influence potently on the hot water energy consumption. The efficiency (COP) measured in this investigation was smaller than that of catalog value, particularly in the winter.
抄録全体を表示
-
籏谷 広司, 横山 真太郎, 嶋倉 一實, 三田村 隆, 土井 豊彦
原稿種別: 本文
セッションID: A-12
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Recently a new sterilizer system using hypochlorous acid water has been presented in food industry. Low concentration of hypochlorous acid water is known to have efficient germicidal power. This paper describes several applications of hypochlorous acid water in air-conditioning and sanitary engineering fields.
抄録全体を表示
-
中村 勉, 城戸 拡宣, 稲田 朝夫, 竹田 喜一, 大武 義人
原稿種別: 本文
セッションID: A-13
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
It made sample according to polymer, combination, filler to improve the chlorine resistance efficiency of the synthetic rubber and it implemented dipping examination by chlorine water. The result is shown below. 1) As polymer, the chlorine resistance is the most excellent in EPDM. 2) In to add Polybutene as the combination , the chlorine resistance efficiency can be more improved. 3) In to adopt FT Carbon as the filler, the chlorine resistance efficiency can be improved in the same way.
抄録全体を表示
-
松浦 吉剛, 紀谷 文樹
原稿種別: 本文
セッションID: A-14
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In the former report, it is necessary to calculate still in detail though calculating simulation program which can calculate the water replacing duration inside residential piping, and several water supply consumption of each water supply appliance as the foundation of diagnostic program. So, in order to calculate as accurate value as possible by this report, it was decides to be calculated by giving change about the water replacing duration to time of each water supply appliance, and the development of the calculation simulation program to diagnose the water quality degradation about the residual chlorine concentration based on the value was done.
抄録全体を表示
-
大森 裕之, 関 五郎, 大橋 一正, 仙川 誠, 高岡 直人
原稿種別: 本文
セッションID: A-15
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This study has verified validity of renewal installing a saved-water type sanitary fixture. At "A" and "B" building, renewal was performed installing a saved-water type sanitary fixture. This study fmds out the use situation of sanitary fixture and analyzes situation of sanitary fixture before and after this building is renewed of sanitary fixture. This investigation and analysis make the data to verify validity of renewal of plumbing equipment.
抄録全体を表示
-
井出 裕一, 岩本 静男, 坂上 恭助, 鎌田 元康
原稿種別: 本文
セッションID: A-16
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In this paper, the prediction method of the inlet water temperature of purification plant shown in the last paper was used and comparison between measurement and calculation results in 2001 and 2002 was performed. And prediction method of water temperature from water purification plant and that in the water pipe from a water purification plant to a building were shown and a series of predictions from a water source to a building was performed for validation of the prediction method.
抄録全体を表示
-
王 祥武, 前 真之, 米田 千瑳夫, 岩本 静男, 斎藤 忠義, 鎌田 元康
原稿種別: 本文
セッションID: A-17
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The simulation method of the system efficiency for dwellings central hot-water supply system that consists of a gas instantaneous hot-water heater and point divergence piping system has been shown before. In this paper, we report the result which enabled it to estimate the amount of gas consumption to the calculation model of gas instantaneous hot-water heater, added improvement that the header-conduit piping system to point divergence piping system, and the influence of the mixing faucets could be considered. In comparison with a calculation result and an experiment result, since the relative error in the amount of gas consumption and system efficiency were settled to less than 2%, it was shown that this estimating method is appropriate.
抄録全体を表示
-
豊島 正樹, 岡島 次郎, 渡邊 興隆, 風間 史郎
原稿種別: 本文
セッションID: A-18
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The technique of solving the temperature distribution in a heat storage tank of the multifunctional heat pump hot water supply system, with high precision, using simple energy balance formula is developed. The feature of a solution method is assuming the thermal diffusion under the influence of buoyant force in a tank to be change of thermal conductivity. As a result, the simulation of temperature distribution in a heat storage tank agrees with examination result.
抄録全体を表示
-
中原 信生
原稿種別: 本文
セッションID: OS-1
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Commissioning Process Guideline for Building Services Systems by SHASEJ committee on Building Commissioning has been finalized on March, 2004. The author, having been the chairman of the committee, likes to explain the object of this organized session, how terminologies sometimes give misunderstanding on the concept of commissioning either with or without intention, discrimination among similar terminologies and why commissioning process is "must", necessarily citing from American state of the art, as he participated in NCBC 2004 held in Atlanta and having much conversations.
抄録全体を表示
-
湯澤 秀樹, 柳原 隆司, 中原 信生
原稿種別: 本文
セッションID: OS-2
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Initial Commissioning-Process is the effective Strategy that realize the Request of Building owner. On the other hand, Since Initial Commissioning-Process is the Paradigm Shift of The Conventional Construction Process; it needs to arrange the Framework. This Paper reports the purpose and procedure, and important matters as the framework of Initial Commissioning-Process of Building Services Systems. In addition, It is introduction of some result articles of Commissioning Guideline Creation subcommittee under SHASEJ committee on Building commissioning .
抄録全体を表示
-
柳原 隆司, 湯澤 秀樹, 中原 信生
原稿種別: 本文
セッションID: OS-3
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This Paper reports a Role of CA (Commissioning Authority) and CRP (Commissioning Relating Parties: Owner, CA, Design Professional, Constniction Supervisor, Contractor, Vendor, Operator, etc.) on each Phase and each Step of Building Commissioning Process. In addition, It is introduction of some result articles of Commissioning Guideline Creation subcommittee under SHASEJ committee on Building conunissioning .
抄録全体を表示
-
松田 則雄, 吉田 新一, 小野島 一, 中原 信生
原稿種別: 本文
セッションID: OS-4
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In Commissioning Process, one of the most important concept is testing, inspection and verification. Usually, they are put into practice by contractors in Japan, moreover, definition and even how far they should be performed are not agreed with among interested party. The present paper described the new definition and scope of works of testing, inspection, adjusting and start-up, when Commissioning Process is applied, according to Commissioning Process Guideline for Building Services Systems issued by SHASE.
抄録全体を表示
-
丹羽 英治, 奥宮 正哉, 菅長 正光, 田中 英紀, 鄭 明傑, 潘 嵩, 渡邊 剛
原稿種別: 本文
セッションID: OS-5
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Results of comparative study for five typical simulation programs (HASP/ACSS, EnergyPlus, DOE-2, Dest and HVACSIM^+ are discussed using. a certain reference model of an actual building. The maximum and annual cooling and heating loads and annual energy consumption are compared. Several case studies have been carried out for each program how design parameters and/or control strategies result on energy consumption and/or indoor environment, which proved availability of each program for commissioning use in various phases depending on their characteristics
抄録全体を表示
-
吉田 治典
原稿種別: 本文
セッションID: OS-6
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In this paper the results of questionnaire survey for the commissioning of building energy management system (BEMS) are investigated and the future scopes of BEMS itself are summarized. Then the performances and features to be owned by commissioning tools embedded in BEM systems are described aiming to provide requirements for the development of commissioning tools.
抄録全体を表示
-
松縄 堅, 柳原 隆司, 古田 康衛, 吉澤 昭彦, 湯澤 秀樹
原稿種別: 本文
セッションID: OS-7
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We have arranged the framework by trial of Commissioning-Process in the past several years. The problem of the present construction process is having not clarified Owner's Project Requirements, and Commissioning-Process is one of the techniques of the ability to improve it. However, still, in Japan, since there is little familiarity, it has some subjects for spreading and promotion. This Paper reports some problems on developing Commissioning Process for utilization arranged based on our experience.
抄録全体を表示
-
平山 昌宏, 中原 信生, 松田 則雄, 千葉 昌義
原稿種別: 本文
セッションID: OS-8
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Commissioning Process Guideline for Building Services Systems by SHASE Committee on Building Commissioning has been finalized on March 2004. We cognized the Starting Point for Diffusion and Development of Commissioning, and establish the Commissioning NPO for Building Equipment.
抄録全体を表示
-
大森 一郎, 荻原 豪之, 竹内 祥貴, 小林 茂樹
原稿種別: 本文
セッションID: B-1
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We developed the biggest one open network BA system which watched and controlled more than 150000 points in the Roppongi Hills Mori Tower without 4,5 conventional systems.
抄録全体を表示
-
大塚 順基, 田代 博一, 寺脇 正文, 小林 浩次, 荻原 豪之
原稿種別: 本文
セッションID: B-2
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Full-distributed AHU (Air Handling Unit) control system was introduced into a building, Roppongi Hills - Mori Tower. It uses open network technologies. On this work, accomplishments were obtained as follows. 1) Full-distributed AHU control system was established. 2) For this system, a new AHU controller was developed. 3) A remote alignment system for AHU controller over LAN (Local Area Network) was developed.
抄録全体を表示
-
久保田 常人, 伊東 民雄, 片山 健一郎, 竹内 祥貴
原稿種別: 本文
セッションID: B-3
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We developed the open network control system in which all new devices (for example the sensors, the valves, the inverters and so on) carried the Neuron tip. Especially in the shopping floor we tried the full-distributed AHU (Air Handling Unit) control system, which utilized the control function of the Neuron tip.
抄録全体を表示
-
久保田 常人, 伊東 民雄, 片山 健一郎, 竹内 祥貴
原稿種別: 本文
セッションID: B-4
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We constructed the new multi-vender BA system not only about the biggest scale but also about the new function. Especially in this report we introduced the new air-condition Web system in order to serve to the office tenants.
抄録全体を表示
-
友田 衛, 柴田 克彦
原稿種別: 本文
セッションID: B-5
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
We developed the VAV system to suppress over cooling as reporting in our previous paper and installed it into the actual facility. As results , it was recognaized that this VAV control system was superior on the individual room temperature to the traditional VAV control system . More over, it was predicted that the energy-saving was about 31.9% per a year, when we select the saving energy mode.
抄録全体を表示
-
竹迫 雅史, 角之上 芳明, 佐藤 文秋, 米木 伸一, 安田 健一, 江崎 晃
原稿種別: 本文
セッションID: B-6
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Abstract: This paper presents the result of energy conservation by Variable Water Volume Control Program for pump head optimization by monitoring each control valve. The results show that this Program is very effective for reduce Power consumed by pumps.
抄録全体を表示
-
柴田 克彦, 高橋 惇, 大神 龍幾, 木山 昌良
原稿種別: 本文
セッションID: B-7
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
At the biological clean-room with a high airtight performance, it is required that the differential pressure between higher room and lower room is not absolutely reversed. So, we have developed the control system that it is installed so-calded VST (Variable Stroke Time) mechanism for air supply, and successive control between dumper control for differential pressure and state of opening and shutting a door by worker. As results of differential pressure control using the test equipment, it was confirmed that the differential pressure did not reverse for changing air-supply volume of HVAC system, and kept stability for opening and shutting door.
抄録全体を表示
-
Utarou Taira, Tan Yong Kwang Alex
原稿種別: 本文
セッションID: B-8
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In this paper, we'll describe about the facilities in the Environmental Engineering Research Center (EERC) of Yamatake Corporation. First part is about the new laboratory built for the purpose of carrying out environmental engineering technology research, especially air-conditioning technology. And, second part is about the results of experiments in this laboratory, for example to control temperature and humidity simultaneously.
抄録全体を表示
-
大森 一郎, 荻原 豪之, 植田 誠人, 小林 茂樹, 竹内 祥貴
原稿種別: 本文
セッションID: B-9
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
For The Roppongi Hills which is a large-scale compound use building as a standard story floor area of about 5700 m^2, and total in floor area 380000 m^2 , the design concept of the air-conditioning-system and its control system were introduced
抄録全体を表示
-
田代 博一, 鈴木 勇, 寺脇 正文, 大塚 順基, 小林 浩次, 荻原 豪之, 植田 誠人
原稿種別: 本文
セッションID: B-10
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In the Roppongi Hills Mori Tower , various and latest technologies concerning the open network technology that is spreading rapidly have been introduced domestically. This paper describes introduction of the Full-distributed AHU control system and the remote maintenance technology .
抄録全体を表示
-
青島 稔, 鈴木 勇, 寺脇 正文, 田代 博一
原稿種別: 本文
セッションID: B-11
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The energy consumption baseline which utilized BEMS introduced into the Roppongi Hills Mori Tower, and was assumed before building completion ,and the actual amount of enegy consumption have been grasped,and it analyzed about the analysis energy-saving effect of an energy field unit.
抄録全体を表示
-
鈴木 勇, 寺脇 正文, 田代 博一, 古川 賢一, 大森 一郎, 久保田 常人, 青島 稔
原稿種別: 本文
セッションID: B-12
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The BA system of the Roppongi Hiruzu Mori tower is an open network multi vendor system. As the introductory effect, the example of BEMS of the open-ized data practical use which evaluates energy saving and indoor environment, and commissioning (performance verification) of automatic control is introduced. In consideration of the automatic control data of 640 points based on open-izing, the energy-saving effects, such as conveyance power reduction [by cold-water round trip difference-of-temperature reservation], outdoor air cooling effect, and CO2 control effect, are checked. In addition, performance verification of automatic control is tried from the action of VAV immediately after completion.
抄録全体を表示
-
沢田 正道, 宮崎 友昭, 竹井 宏, 神村 一幸, 松葉 匡彦, 田口 宣夫, 大曲 康仁
原稿種別: 本文
セッションID: C-1
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This report shows the effect of energy saving for the buildings that include the optimum DHC-system, and look forward the spread of this system.
抄録全体を表示
-
大曲 康仁, 神村 一幸, 田口 宣夫, 沢田 正道, 宮崎 友昭, 竹井 宏
原稿種別: 本文
セッションID: C-2
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The combination control of VWV and VWT is developed and evaluated. The combination control needs to solve the trade off between the reduction of chiller energy consumption and the increase of the pump energy consumption according to the raise of the chiller water temperature. The VWT control changes the set point of chiller water temperature to reduce the total energy consumption using estimation models. By the provisional estimation based on the actual measurements, VWV/VWT combination control can reduce 50,000[kg-CO2/year], and it equal to the 5% of chillers and pumps energy consumption except for the auxiliary equipment.
抄録全体を表示
-
神村 一幸, 松葉 匡彦, 田口 宣夫, 沢田 正道, 宮崎 友昭, 竹井 宏
原稿種別: 本文
セッションID: C-3
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The optimal control system for real-time operation of a district heating cooling and power plant was evaluated through a year operation concerning the improvement of its control performance and the reduction of CO_2 emission and operational cost of a plant. Through the evaluation, the optimal control system was estimated to reduce 4% CO_2 emission and 2 % operational cost of a plant. The optimal control system is continuing the control of the district heating cooling and power plant successfully for more than 1.5 years since the start of the evaluation.
抄録全体を表示
-
松葉 匡彦, 田口 宣夫, 神村 一幸, 宮崎 友昭, 竹井 宏, 沢田 正道
原稿種別: 本文
セッションID: C-4
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
In this paper, the effectiveness of using forecasted temperature profile for the multi-input load profile prediction, applied to a district heating, cooling and power plant, based on time series analysis, is evaluated by comparison with single input prediction model. Forecasted data contribute to improve the accuracy of a daylong prediction. And another thing, forecasted outdoor temperature profile updated twice a day provides a good performance of load prediction comparable to those hourly updated.
抄録全体を表示
-
竹井 宏, 宮崎 友昭, 沢田 正道, 神村 一幸, 田口 宣夫
原稿種別: 本文
セッションID: C-5
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
This report shows the contents of control factor, calculation result, problem on usage, and future stage of load-saving control system.
抄録全体を表示
-
三好 宏治, 井上 隆, 射場本 忠彦, 百田 真史, 柳原 隆司, 萩原 利昌, 岡垣 晃, 呉 賢明
原稿種別: 本文
セッションID: C-6
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
On the district heating and cooling (DHC) with a huge thermal storage tank, the analysis was performed focusing on three-year operation. The analysis in long term contains energy transaction, chiller operation, and plant operation such as the night-shift-rate and the primary-energy-conversion COP. As a result, it turned out that the night-shift-rate of quantity of heat gradually increased and the high COP was kept for these three years.
抄録全体を表示
-
中村 友久, 井上 隆, 射場本 忠彦, 百田 真史, 宮本 和弘, 萩原 利昌, 岡垣 晃, 呉 賢明
原稿種別: 本文
セッションID: C-7
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Focusing on the main facilities in district heating and cooling (DHC), this study evaluated performance and annual change of the main facilities based on measured data for three years after completion and showed effects of re-commissioning the following results 1)improving COP in the mid-term by reconsideration of low limit of cooling water temperature in chiller 2)changing operation pattern in thermal storage tank 3)becoming operation pattern as a design by low limit of cooling water temperature in cooling and heating tower 4)improving temperature difference between inlet and outlet by lowered supply temperature of chilled water and reducing electric consumption by changing control of operation in transportation pump.
抄録全体を表示
-
百田 真史, 井上 隆, 射場本 忠彦, 三原 一伸, 萩原 利昌, 横田 雄史, 呉 賢明, 伊勢田 元
原稿種別: 本文
セッションID: C-8
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
With a system simulation of the DHC which have been analyzed in previous studies, we studied on how this DHC was achieved the high performance. On the basis of DHC system simulation results, we investigated about an effect of changing parameter. Through each comparison, it was shown that to enlarge a thermal storage tank, to introduce high COP Chillers and to decrease an inlet temperature of chilled water were effective.
抄録全体を表示
-
藏本 誠, 篠原 道正, 村川 三郎
原稿種別: 本文
セッションID: C-9
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
Heat supply conditions were analyzed on DHC system constructed in Hiroshima city. As a result, it was appeared that the operating time at the partial load is very long and system COP fell in these cases. In this paper, operating conditions were analyzed on three turbo refrigerating machines to evaluate energy saving. COP and SCOP were obtained by function of chilled water temperature and cooling water temperature expressed as load factor function. At last, energy efficiency is simulated by variable water volume system.
抄録全体を表示
-
萩原 利昌, 塩出 勝, 宮内 陽治郎, 松永 澄明
原稿種別: 本文
セッションID: C-10
発行日: 2004/08/20
公開日: 2017/08/31
会議録・要旨集
フリー
The energy of supply chilled water pump for District Heating and Cooling is consumed from ten for 20%. Chilled water pump using the inverter save 40% energy by lowering 0.08Mpa supply pressure. It is important to lower the supply pressure as much as possible.
抄録全体を表示