Suiqing LIU
Article type: Article
Session ID: IS-1
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Water resources management in China is one of the national strategies for overcoming the water shortage problem and meeting the water demand for social and economic development. The changing characteristic and variation tendency of the water demand from different aspects were analyzed. Aiming at the main problems of water resources management approaches for sustainable utilization of water resource and water saving technology requirement were presented, including the water conservancy projects, national policies on water resource management and water-saving technology development.
View full abstract
-
Wen-Hung Lu, Cheng-Li Cheng, Chia-Ju Yen
Article type: Article
Session ID: IS-2
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
-
Takashi Kurihara, Masaharu Okuda, Takashi Fukumura, Masashi Inoue, Ken ...
Article type: Article
Session ID: IS-3
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report describes a water-saving toilet that uses just six liters of water per flush. The performance of this toilet is compared with that of an 8-liter toilet. The 6-liter toilet is highly reliable and operates by conventional gravity drainage, so additional energy is not required for special facilities such as vacuum or pressure transportation systems. The new system also offers an improved the shape of the bowl, an automatic flush valve with excellent flow characteristics, an optimized drainage pipe inclination, etc. This report also describes the good discharge performance of the 6-liter toilet.
View full abstract
-
Daisuke Yamanouchi, Masayuki OHTUKA, Toshihiro SANKAI
Article type: Article
Session ID: IS-4
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
-
Noriyoshi Ichikawa, Yoshiharu Asano, Shin Sumikawa, Mariko Yamada
Article type: Article
Session ID: IS-5
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
-
Saburo Murakawa, Hiroshi Takata
Article type: Article
Session ID: IS-6
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
-
Takatoshi MIZUTANI, Noriyoshi ICHIKAWA, Fumitoshi KIYA, Masayuki OTSUK ...
Article type: Article
Session ID: A-1
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The evaluation of the water saving equipment was mainly reduce for the flowrate and water volume till now. Our study subject are the establishment of the integrated evaluation technique for consistently catching the flowrate, the pressure, the temperature, the global environment load until abandoning from resource and the influence factor to the ecosystem with the effect of water saving. In this paper, the authors described it about experiment results to clarify the water supply performance of several water saving equipment.
View full abstract
-
Satoshi ASANO, Yoshiharu ASANO, Hideki TAKAMURA
Article type: Article
Session ID: A-2
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The authors investigated usage in the washrooms and the sanitary fixtures in a primary school. In this paper, tendency of usage in the washrooms of primary students by comparison with past research effect were made clear. No differences between primary school in Nagano City and Matumoto City about occupied time of the sanitary fixtures were made clear. The results of investigation were as follows; 1) The time of occupation of the urinal in the boy washroom was about 20 secs, and the basin in the boy washroom was about 5 secs. 2) The time of occupation of the woman toilet was about 50 secs, and the basin in the woman washroom was about 10 secs.
View full abstract
-
Masashi YASUOKA, Toshihisa MATSUSHIMA, Takahiro OMOTO
Article type: Article
Session ID: A-3
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In late years a construction rush of a super high-rise building continues around Tokyo urban region. The usage of the building extends variously. Supply of stable life water for such a super high-rise building is the indispensable problem. Therefore I aimed for grasp of quantity of reasonable water supply and confirmation of follow of water supply pressure. And I measured actual survey of amount of water used and the driving situation of a feed pump in the super high-rise building with particularly few report cases. Because the data measurement of one year ended, it reports on the outcome to here.
View full abstract
-
Shinji Kosaka
Article type: Article
Session ID: A-4
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The amount of annual water consumption was decreasing sharply in the past 25 years. Data were collected about the factor which has relation in the amount of water consumption. If it can contribute to a future design condition determination is considered.
View full abstract
-
Keiko MURO, Yasuo KUWASAWA, Takeshi KONDO
Article type: Article
Session ID: A-5
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Energy consumption of hot-water supply is to account for about one third of household energy consumption. For energy conservation, reducing the energy consumption for hot-water supply plays a big part. As basic research towards reducing hot-water consumption in daily life, we determined the minimum required water temperature for daily use by subjective experiments, and we calculated the energy-saving effect of not using hot-water by supplying the preheated water. The results showed that 50% of subjects accept the water temperature of 24 degC for usually use. And the water temperature of 28 degC is necessary for 90% of subjects to accept. If preheated water is supplied to kitchen and bathroom vanity, 30% or less of heat requirement for hot-water supply will be reduced, and if preheated water is supplied to all of household water use, there is possibility of reduction in about 75% heat requirement for hot-water supply.
View full abstract
-
Takanori ITAI, Saburo MURAKAWA, DAISAKU Nishina, Hiroshi TAKATA
Article type: Article
Session ID: A-6
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The purpose of this study is to obtain the characteristics of the energy consumption in welfare facilities for aged. This paper shows the relationship between amount of heat supplied and energy consumption of hot water supply system in winter and summer of two welfare facilities. T facility and S facility use the electricity and the gas as a heat source, respectively. We showed that the efficiency of the hot water supply system of T facility is high compared with S facility.
View full abstract
-
Naoki YAMAMOTO, Saburo MURAKAWA, Hideo ISHIMARU, Daisaku NISHINA, Hiro ...
Article type: Article
Session ID: A-7
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In designing and planning of the building systems, we need the accurate estimation of energy consumptions and the correct decision of performance and capacity. Therefore, it is important to survey and study on the actual condition of energy consumption in each building. However, the data of energy consumptions in a hot spa facility is insufficient. The purpose of this study is to clarify the characteristics of hot water and energy consumption of a hot spa facility in Hiroshima.
View full abstract
-
Hiroki KITAYAMA, Saburo MURAKAWA, Yasuhiro HAMADA, Minako NABESHIMA, H ...
Article type: Article
Session ID: A-8
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Development and Installation of energy efficient hot water supply system using CO2 heat pump is increasing. For the purpose, it is very important to grasp the system performance and hot water usage in actual condition. Field survey on the hot water consumption and the performance of CO2 heat pump water heater was carried out in 13 residential houses of 7areas Japan. The survey consists of 2 parts, on-site measurement and questionnaires. In this paper, outline of the survey, daily and hourly fluctuation of hot water consumption in winter was shown. Time variations of hot water consumption based on the measurements were compared with the results of questionnaire.
View full abstract
-
Hiroshi TAKATA, Saburo MURAKAWA, Hiroki KITAYAMA, Yasuhiro HAMADA, Min ...
Article type: Article
Session ID: A-9
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The authors analyzed the performance for the CO2 heat pumps equipped in the hot water supply systems of each house based on the results of field measurements. This paper presents the measurement results on the thermal and energy efficiency of heat pumps through the winter season. As the results, the average results of coefficient of performance (COP) on the heat pumps are shown based on the characteristics of hot water usage and outdoor temperature, etc. And, the efficiency of the steady and the unsteady running condition and the defrosting condition of heat pumps are analyzed by the factors of outdoor temperature and humidity of heat pump unit. Finally, the authors clarify the COP of the hot water supply system in winter.
View full abstract
-
Masaya IHARA, Takeshi KONDO, Shizuo IWAMOTO, Takashi KURABUCHI, Masayu ...
Article type: Article
Session ID: A-10
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, CFD and a simple calculation method are used in order to predict water temperature distribution of hot water storage tank in natural refrigerative heat pump hot water supply system. Both calculation results are compared with the experimental result and the simple calculation method are refined by CFD calculation result when water in the storage tank is heated or hot water supplied.
View full abstract
-
Masayuki MAE, Kiyoshi FUKUZAWA, Makoto SATO, Motoyasu KAMATA, Shizuo I ...
Article type: Article
Session ID: A-11
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Hot water occupies one third of total residential energy consumption, and usage in each house varies so widely. Usually heater's efficiency is evaluated in stable usage, but most important is actual one in real houses. To evaluate the real efficiency, we studied the relation between the property of hot water usage and the efficiency of gas and oil hot water boiler. Then we made the "Usage Mode" from the usage measured in 10 houses, and developed the evaluation method of real efficiency by that mode. In this paper, we analyzed the efficiency fluctuation of gas instantaneous heater produced by the usage.
View full abstract
-
Takayuki SANO, Takeshi KONDO, Shizuo IWAMOTO, Masayuki MAE, Kiyoshi FU ...
Article type: Article
Session ID: A-12
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this research, the efficiency of oil water heater was measured. The efficiency in steady flow operation, mode operation, and interval operation was measured. The effects on efficiency of surrounding temperature, water supply temperature, and hot water flow rate were examined. The result suggested that the efficiency increased by 3% when surrounding temperature rised and 5% when hot water flow rate rised. The prediction of efficiency using the average heat of hot water supply was carried out.
View full abstract
-
Chieko EDO, Makoto SATO, Masayuki MAE, Kiyoshi FUKUZAWA, Motoyasu KAMA ...
Article type: Article
Session ID: A-13
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this report, the Supplying Hot Water Usage Mode making method when the efficiency of a domestic gas and the oil heater is described. It was discovered that the heat efficiency for instantaneous hot water heaters was affected on a micro level with regards to the amount of continual time used during a single action, the interval between actions, and the number of actions implemented, and hot water accumulators were affected by the time zone distribution for the actions on a micro level, so these different heat efficiency characteristics were taken into account when creating the Usage Mode. Moreover, the outline concerning ten measurement data to contribute to the Usage Mode making was described.
View full abstract
-
Makoto SATO, Masayuki MAE, Kiyoshi FUKUZAWA, Motoyasu KAMATA, Chieko E ...
Article type: Article
Session ID: A-14
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research aims at the standardization of the efficiency by a Usage Mode in the water heater in which the gas and oil are assumed to be a heat source. This paper describes a making of supplying hot water usage mode. The Standard Usage Mode consists of a combination of the reason for water use and the volume used for each action and the continual amount of time it was used for each action, and the number of actions that hot water was used over the period of one day for a household consisting of four people (a couple and two children) was set at 51 times, with 455L of hot water calculated at a temperature of 40 degrees Celsius used.
View full abstract
-
Kiyoshi FUKUZAWA, Masayuki MAE, Takeshi KONDO, Makoto SATO, Takayuki S ...
Article type: Article
Session ID: A-15
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this report, the result of experimenting on efficiency of various changes of the ambient temperature and the water supply temperature by the Standard Usage Mode and the Multi Usage Mode is described. The purpose of the efficiency experiment is two points (the grasp of the influence that the ambient temperature, the water supply temperature of the heater, and the Usage Mode give efficiency and the grasp of the change in efficiency according to the kind of the heater). As a result, the efficiency in winter rose in the latent heat collection type while the efficiency of summer rose in the expression heater as for the old model momentarily when the experimental condition was seen.
View full abstract
-
Masayuki YAMAMOTO, Ken KURIYAMA, Yasuhiro NAKAMURA, Takeshi MATSUYAMA
Article type: Article
Session ID: B-1
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
An optimum control of heating and cooling plant with thermal storage tanks and refrigerators operated at discrete points is a large-scale mixed integer plan problem. In the previous paper, we proposed a practical approximation method without using the mixed integer programming. In this paper, we investigate into heat supply from thermal storage tanks calculated by previous method to easily solve our difficult problem by simplex method.
View full abstract
-
Takeshi MATSUYAMA, Yasuhiro NAKAMURA, Ken KURIYAMA, Masayuki YAMAMOTO
Article type: Article
Session ID: B-2
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The authors showed that a large-scale driving plan through a day could return to the most optimum driving control of a refrigerator every single time if they used heat release from heat storage tank calculated by the most optimum control technique of previous paper 4) as an efficient driving plan by a previous report. We are based on this result by this report and state technique to demand a driving plan for machinery having the nonlinearity which is a pump of stage refrigerator and ON-OFF type running with mixture integer plan law.
View full abstract
-
Hideharu KOMODA, Ken YAMAMOTO, Mariko KAMIYA
Article type: Article
Session ID: B-3
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The partial thermal load at that point of design is widely different from operating. This paper describes analysis energy-saving effect based on the energy-simulation for Hybrid Heat Source System with ice storage system in order to energy-saving at the point of operating system.
View full abstract
-
Toru YAMAMOTO, Eiichi SUZUKI, Michio KOJIMA, Akemi TAGUCHI
Article type: Article
Session ID: B-4
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper shows the situation of action activity which is energy conservation by using BEMS data effectively. In developed system, a set point of second side air conditioning facility was changed and controlled. Furthermore, a characteristic of energy demand of a building and operating performance characteristic of heat source machinery was analyzed, and optimal operation of heat source system was planned.
View full abstract
-
Keiji KUNIYOSHI, Yasunori AKASHI
Article type: Article
Session ID: B-5
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper addresses the effects of optimization of PID parameters in building air-conditioning systems. On the optimization of PID parameters, we proposed optimum adjusting strategy using GA. It simulates mechanisms of organisms' heredity and evolution. The strategy simultaneously searches multiple kinds of PID parameters of VWV 2-way valve and VAV unit. As a result of the calculation, it was confirmed that GA was an effective strategy when PID parameters of the multiple controls were found.
View full abstract
-
Yoshiaki YUMOTO, Ryuji YANAGIHARA, Toru ICHIKAWA, Tatsuo NOBE, Shigeki ...
Article type: Article
Session ID: B-6
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The performance of an unitary air-conditioner is evaluated by JIS or JRA rules. However, the tests are done in static condition, and the actual performance is not evaluated. These false estimates produce a different anticipation of future energy consumption or waste heat contamination. In this paper, an easy method for actual performance evaluation is studied, and discussed the way of a method from outdoor unit.
View full abstract
-
Yusuke HAGA, Satoshi SHIMIZU, Tatsuo NOBE
Article type: Article
Session ID: B-7
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research is developed of an actual performance evaluation system of package air-conditioner. We developed the sampling system to measure heat rejection from outdoor unit. As for the developed sampling system, an actual performance of the package air-conditioner is appreciable. Performance of operated package air-conditioner was evaluated by using the sampling system.
View full abstract
-
Satoshi SHIMIZU, Yusuke HAGA, Yoshiaki YUMOTO, Shigeki KAMETANI, Tatsu ...
Article type: Article
Session ID: B-8
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research is accuracy verification of sampling system of heat rejection flux from outdoor unit .In the calorie box, it experimented 14 kinds of environmental condition of indoor and outdoor. The energy consumption efficiency of air-conditioning system was measured by three kinds of measurement procedure, the heat balance method, outdoor unit and sampling system of heat rejection flux from outdoor unit. The accuracy of sampling system of heat rejection flux from outdoor unit was verified compared with other kind of measurement procedure.
View full abstract
-
Ken SEKIYAMA, Motoi YAMAHA, [in Japanese]
Article type: Article
Session ID: B-9
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, we examine new methods that can evaluate machinery performance as Functional Performance Tests when on-going commissioning is applied to existing buildings with VRV systems. Therefore the simulation program that used a refrigerate cycle estimates energy consumption, and operating of equipments is evaluated by comparing it with actual energy consumption. This method can detect low setting point of indoor temperature and malfunction of equipment by deciding the upper limit value.
View full abstract
-
Anna WON, Satoshi YOSHIDA, Satoru SADOHARA, Shigeki KAMETANI, Tatsuo N ...
Article type: Article
Session ID: B-10
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The aim of this paper is to discuss the merit rating of Package Air-conditioner system on working normal times. For this purpose, we have an actual measurement in summer and winter that are lots of use of Energy consumption for Heat and cooling. The result of pattern of energy consumption and energy efficiency are showed as follows. The actual measurement COP of Air-conditioner in summer and winter shows a pretty low numeric result than COP published even if consideration to difference weather condition case by case.
View full abstract
-
Satoshi HASHIMOTO, Kosuke SATO
Article type: Article
Session ID: B-11
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Recently, the coverage of multi-split type air-conditioning system for building has expanded. As a result, total energy consumption by the air-conditioning systems is increasing. This paper discusses a visualization method for the operation data of multi-split type air-conditioning system. This method is effective for the optimizing of operation and design of the air-conditioning system that contributes to the energy saving. First, the concept of visualization is explained. Next, the examples of visualization are shown. Finally, the effectiveness is discussed.
View full abstract
-
Kosuke SATO, Satoshi HASHIMOTO
Article type: Article
Session ID: B-12
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper discusses effectiveness of the visualization method for the operation data of multi-split type air-conditioning system proposed by the former report. First, the characteristic of multi-split type air-conditioning system is analyzed, by applying the operation data of actual office building. Next, the best approach of operating, design, and developing equipment by applying this method is discussed.
View full abstract
-
Masahide Furukawa, Masafumi Hirota, Choyu Watanabe, Katsuaki Nagamatsu ...
Article type: Article
Session ID: B-13
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The partial load performance tests of multi-type package air-conditioner for buildings, the rated cooling performance of which was 56 kW, were carried out by using the air-enthalpy method testing apparatus. The annual energy consumption measured by those tests was closely compared with that estimated from the current calculating method. It was found that the current calculating method could not reproduce the deteriorations of COP that appeared under the low thermal load condition in both the cooling and heating seasons. As a result it seriously underestimated the annual energy consumption; the error amounted to as large as about 20% of the measured annual electric power consumption.
View full abstract
-
Fulin WANG, Hanunori YOSHIDA, Keiji MATSUMOTO
Article type: Article
Session ID: B-14
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, it is necessary to develop a method to estimate the energy consumption of air conditioners during a short time interval, such as one minute, to match the control interval, which is one minute in common. This paper proposes a method to estimate the energy consumption of air conditioners using the short time interval room air temperature simulation. The estimated energy consumptions are compared with measured values. The comparison shows that the estimation results are accurate enough to for evaluate the energy performance of a room air-conditioner's control algorithm.
View full abstract
-
Takaharu KAWASE, Yasushi KONDO, Toshihiro SUGIURA, Satoshi HASHIMOTO, ...
Article type: Article
Session ID: OS-1
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The idea of work-place productivity is expected to become an increasing important subject in the field of building servicing engineering. There has already been much research in this field outside Japan. It is possible to create new concepts of work-place productivity by applying a new technique which integrates past research. But more research and information are necessary to apply the idea to the actual planning of buildings. In this paper we summarize the history of research in this field and discuss important problem for the future.
View full abstract
-
Toshihiro SUGIURA, Satoshi HASHIMOTO, Masaaki TERANO, Masaharu NAKAMUR ...
Article type: Article
Session ID: OS-2
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We have reported that the indoor environmental improvement has high possibility to increase the productivity of occupants and to bring a large amount of profit to a building owner and a manager as a result. But there are few information to explain this easily, and positive indoor environmental improvement is not carried out. Therefore establishment of an assessment method of productivity is important. In this report, the result of research and study on subjective assessment method of productivity is reported.
View full abstract
-
Naoe NISHIHARA, Shin-ichi TANABE
Article type: Article
Session ID: OS-3
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, the objective evaluation of the effect of indoor environmental quality on productivity are reviewed and discussed. The objective evaluation methods mainly consist of 1) quantification of the performance, and 2) quantification of the human responses, that affect task performance, such as fatigue and mental workload. As for the quantification of the performance, the office simulated tasks for the subjective experiments, and automatic measuring system for the field study in offices such as call centers are reviewed. As for the quantification of the human responses with indoor environmental quality, the evaluation method of cerebral blood flow, flicker value and human voice for measurement of fatigue and mental workload are discussed.
View full abstract
-
Shin-ichi TANABE, Naoe NISHIHARA, Masaoki HANEDA
Article type: Article
Session ID: OS-4
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Several experiments in moderately high temperature environment were mentioned in this paper. In experiment in short period exposure, the effects on task performance were contradictory among the task types, while the subjects complained the feeling of mental fatigue more, and more cerebral blood flow were required to maintain same level of task performance at hot condition than that at thermally neutral condition. In experiment with long period exposure, indoor air temperature had effects on task performance, and the relationship between performance and complaints of fatigue were shown. Also, an example of field surveys was mentioned which showed the decline in performance in warmer environment.
View full abstract
-
Takashi AKIMOTO
Article type: Article
Session ID: OS-5
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Nowadays office environment that could increase workers' productivity is expected to be designed. Task/ambient conditioning system (TAC) is one of the systems that could remove local heat load effectively and create his/her preferred thermal environment. Subjective experiments with TAC were conducted to investigate the impact of TAC on occupants with regard to their productivity in a climate chamber and a real office environment. Results showed that TAC could contribute to increase their productivity. However, to know the real performance of TAC on productivity, further investigation on evaluation methods will be required.
View full abstract
-
Takamasa KANEKO, Shuzo MURAKAMI, Kazuhide ITO, Hitoshi FUKAO
Article type: Article
Session ID: OS-6
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper gives the summary of study on the productivity in classroom, focusing on the effect of the air quality and thermal environments on academic performance. Especially, study on consistency in productivity evaluation between the field test and experiment is a feature of this study. It also evaluates the consistency between objective and subjective evaluations of academic performance. This multilateral study indicates that improving indoor environment conditions in classrooms can substantially improve academic performance.
View full abstract
-
Yasuhiro SHIRATORI, Hiroaki TAKAI, Katsuhiko HIRANO, Takaharu KAWASE, ...
Article type: Article
Session ID: OS-7
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper describes the case study on the continuous subjective assessment of workplace productivity (WPP) in the T corp. building. During the study of 2 years, indoor environment was changed by moving and improved in office workplace, and it is confirmed that dissatisfied rate with 5 elements of indoor environment and WPP reflect the change of indoor environment sensitively. And unique open workplace make a good effect for WPP. Comparison of dissatisfied rate and WPP with other building is also reported.
View full abstract
-
Shigeyuki MATSUOKA, Yoshio MASUKAWA, Norio KUZUOKA
Article type: Article
Session ID: C-1
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report shows the operation results and, outlines the evaluation of operation results and the process of our long term operational improvement of the system in a large-scale complex of buildings. In this long term this operational improvement, the efficiency of the system was significantly improved in recent year, power demand leveling was achieved. Continuous confirming the operation data and evaluation of operation results proved useful and vital in the process.
View full abstract
-
Yoshio MASUKAWA, Norio KUZUOKA, Shigeyuki MATSUOKA
Article type: Article
Session ID: C-2
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report is about the actual electric power use in office rooms. In this building, we analyzed the amount of electric power of distribution panels, and measured the electric power consumption of the lighting and the outlet in a office room. The electric power use in office rooms is various depending on time and space. The actual electric power use is very small compared with the power supply capacity of the room for rent specification.
View full abstract
-
Masao Kimura, Michiro Shimazu, Masahiro Murai, Takuo Soga
Article type: Article
Session ID: C-3
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In the school plant with the water thermal storage tank, the best refrigerator for current capacity of the thermal storage tank was selected, renewed in measuring driving the temperature distribution in the air-conditioning load and the thermal storage tank and the refrigerator, and the optimization of the operation of the entire system was achieved.
View full abstract
-
Masahiro TAKEDA, Kosei SATAKE, Daiji AKAIWA, Susumu NAKANO, Masaya END ...
Article type: Article
Session ID: C-4
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In large-scale complex buildings with temperature-stratified thermal storage tank, the driving adjustment of the heat source system was performed based on analytical results of BEMS. The energy conservation effect acquired from driving adjustment of heat source system is described in this report. The future agenda is also mentioned.
View full abstract
-
Takao YOSHIKAWA, Kazunobu SAGARA, Toshio YAMANAKA, Hisashi KOTANI, Nob ...
Article type: Article
Session ID: C-5
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The thermal energy storage system is often used from the viewpoint of economy, but its optimum operation is difficult. It is said that the situation of various systems can be understood from changing the temperature profile in the tank. Therefore, this research aims to establish the Fault Detection technique for applying the focus at the temperature in the tank as part of developing a tool for the optimum operation. In this paper, results of trial of Fault Detection by using the data of temperature stratified thermal storage tank are presented.
View full abstract
-
Ken-ichiro TAKESHIMA, Kazunobu SAGARA, Toshio YAMANAKA, Hisashi KOTANI ...
Article type: Article
Session ID: C-6
Published: September 05, 2006
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is difficult to know the behavior of air-conditioning system with thermal energy storage tanks, because almost all systems do not have flowmeter. The aim of this research is to estimate the flow rate of such air-conditioning systems, using temperature in tanks which is easy to measure. In this paper the effect of the number of temperature measuring point in tanks on the estimation accurancy will be reported.
View full abstract