Sadanori KODERA, Mitsunori OGAMI, Keiko MURO, Noriyoshi ICHIKAWA, Hiro ...
Article type: Article
Session ID: A-1
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Relationship between household attributes and water use on water use from questionnaires, surveys and study reports the results of measurement on the time series variation in water supply and water supply facilities
View full abstract
-
Shizuka HORI, Noriyoshi ICHIKAWA, Sadanori KODERA, Masayuki MAE, Hiros ...
Article type: Article
Session ID: A-2
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to construct the method of optimization of water supply for design in housing complex. The amount of the water use and the water supply pattern of the housing complex have changed by a decrease in the number of homes / declining birthrate and a growing proportion of elderly people / and various factors of the lifestyle modification etc. In this paper / it reports on the result of the survey on the peak of the water usage in housing complex.
View full abstract
-
Tamio NAKANO, Noriyoshi ICHIKAWA, Sadanori KODERA, Hiroshi TAKATA, Mas ...
Article type: Article
Session ID: A-3
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, the authors investigated the water usage in housing complex in recent years. It was comparison and verification to be the problem the load of water supply for design in housing complex about three general design standards and the model of the conversation of water supply by the housing type. As a result, it became clear that the model of the conversation of water supply by the housing type is efficiency at the actual design. And it was necessary to do the proposal about service level of water supply.
View full abstract
-
Kazuhiko SAKAMOTO, Saburo MURAKAWA, Hiroshi TAKATA, Keisuke OHCHI
Article type: Article
Session ID: A-4
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The authors carried out measurements about the volume of water supply loads and the consumed amount of electric power by booster pump system in a super high-rise apartment house. Based on the results of measurements, the trend of fluctuation of water consumption and electric power were analyzed. As a result, we showed that it was possible to hold down the increase of the consumption of electric energy by using the suitable water supply system on the basis of the high accuracy for water supply demands estimation.
View full abstract
-
Takumo MIYANAGA, Toshihiro SANKAI, Fumitoshi KIYA, Yoshihiko ABIKO, Ma ...
Article type: Article
Session ID: A-5
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In case of earthquake-stricken, peoples have to prepare themselves for disruption of water infrastructure. Especially, it is vital to retain the domestic noncommercial water for resident of skyscraper condominium. Above all, they need flash water of toilet in a time of disaster. Therefore, the authors research about the emergency water supply of local governments etc. In the result, emergency water supplies vary from local governments to residents. So the authors suggest that resident of skyscraper condominium need quantity of water till the restoration of infrastructure.
View full abstract
-
Hitoshi AKAI, Keiko NOCHI, Fumi SAKANAKA, Katsuhiko NAKAMURA, Seishi O ...
Article type: Article
Session ID: A-6
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is important for the circulation type bath to control the residual concentration of disinfectant as precaution against Legionnaires' disease. In this study, we analyzed and examined the distribution of residual chlorine concentration, and the correlation of the residual chlorine concentration between the bathtub and the chlorine control detection sensor, which were gained from the investigation at 2 bath systems in Hokkaido in July 2009.
View full abstract
-
Keita FUKUI, Seishi OKADA
Article type: Article
Session ID: A-7
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, bathwater hardly shows displeasure to bathing with a family by practice, displeasure is often shown in a public bathhouse. As for a bathtub, the thing in which the human elution and detergent of the substance from the body adhered to the body, and also a disinfectant are mentioned by human bathing. Then, bathwater is extracted about a real bathtub and research is advanced for the purpose of grasping the actual condition of offensive odor. The bathtub underwater odor could be expressed with odor concentration, and this odor concentration was set to "42."
View full abstract
-
Masaki SUGOH, Keiko NOCHI, Masayuki OTSUKA, Masamistu OGAWA, Hitoshi A ...
Article type: Article
Session ID: A-8
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, it dealt with dissolved organic carbon by the biological activity charcoal, and bacteria carried out inhibiting experiment by the hollow fiber membrane method In addition, ultraviolet irradiation and chlorination were used jointly. By the hollow fibermembrane method, bacteria were stopped. However, it was proven to remultiply by the cyclic use process. Then, though as a result bf using the ultraviolet irradiation method jointly, the inactivation rate of bacteria heightened, it was not possible for the no detection. The sake was that hollow fiber membrane method which solves these used the chlorination jointly. The condition was that it made the chlorination concentration to be with 2mg/L and makes the intermittent flow and on to be the filtration tank back step in 4 time/d.
View full abstract
-
Yuta Yamagishi, Masaaki Ogawa, Kazuo Muramatu
Article type: Article
Session ID: A-9
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Continuous filtration causes the suspended matter trapped in the filter to accumulate in the filter layer. This necessitates the cleaning of the filter layer on a periodic basis in order to restore the layer to its original state and condition. This paper reports on a new back-flow cleaning method that is more efficient than the conventional back-flow cleaning, and it provides the performance evaluation results of this method.
View full abstract
-
Masaki IMAI, Seishi OKADA
Article type: Article
Session ID: A-10
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study relates to density of disinfectant management. When it is used water in a building-related institution, a disinfectant must be included than rule density by all means. Chlorine and chlorine dioxide are used for the disinfectant mainly. Therefore this study experimented on a factor to lead to density of disinfectant decrease. The factor took up water temperature, atmosphere opening or sealing up, contact materials, reaction with the underwater ingredient.
View full abstract
-
Toshihiro SANKAI
Article type: Article
Session ID: A-11
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
To reduce Environmental Load from TANDOKUSHORI-JOKASO, We develop Wastewater Treatment System Based on Water-Saving Technology. On this Paper, some Results of Study concerning Characteristics of Concentrated Wastewater Treatment by TANDOKUSHORI-JOKASO are reported.
View full abstract
-
Hideaki HOSHINA, Masayuki OTSUKA, Toshitaka KATOU, Masanobu INOUE
Article type: Article
Session ID: A-12
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study a basic drain performance was evaluated by using the drainage piping of a high-rise model as an examination of the initial stage to apply a business disposer to a business building of the high-rise. In this paper, reports on three of the the drain ability experiment, the transportation performance experiment, and high-pressure washing experiments.
View full abstract
-
Shunsuke AKAMA, Nobuharu MAEDA, Seishi OKADA, Keita FUKUI
Article type: Article
Session ID: A-13
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research clarified the characteristics and the processing effect of the system which carries out solid liquid separation with a sedimentation tank, and processes water. It aimed at comparing with the system which furthermore installs an electrode directly and has not established the circulation course. The effect was accepted as a result. Moreover, since selection of a setting position can be performed easily, when introducing a system newly, it is thought that it is effective. It is thought also in comparison with other processing systems that it is significant.
View full abstract
-
Azusa MORI, Kaori USAMI, Yoshihiro KATO, Masashi MIURA, Norifumi ISU
Article type: Article
Session ID: A-14
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The influence of flushing water on the precipitate formation from urine in drainpipes was investigated. In the case of using flush water, hydroxyapatite and amorphous calcium phosphates were precipitated as rigid scale on the surface of drainpipe. In contrast, in the case of waterless condition, struvite was precipitated in gel-like matrix composed of amorphous calcium phosphates and organic compounds, resulting from high concentration of urine and high pH. It is suggested that the waterless condition prevents the formation of rigid scale on the surface of the drainpipe.
View full abstract
-
Hironori YAMASAKI, Masayuki OTSUKA, Yuta TAKAHASHI
Article type: Article
Session ID: A-15
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study proposes a method for testing the performance of a toilet with an uroflowmeter, which is developed for this very purpose, when the toilet is installed to a stack system, and examines how effective the method may be according to the results, with the intention of clarifying the variation of pipe pressure allowable when the toilet is installed to a drainage ventilation system.
View full abstract
-
Yuta TAKAHASHI, Masayuki OTSUKA, Hironori YAMASAKI, Hiroshi IDA
Article type: Article
Session ID: A-16
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study proposes a method for testing the performance of a toilet with an uroflowmeter. This paper applies three point evaluations suggested by the previous paper, discusses performance evaluation method when the toilet is installed to a loop .vent pipe system. At the same time, this paper discusses validity of design method of loop vent pipe system.
View full abstract
-
Aya MATSUMOTO, Mari MOROKAWA, Kanako TOYOSADA, Yasutoshi SHIMIZU, Kyos ...
Article type: Article
Session ID: A-17
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We investigated the consciousness and the actual condition for excretion sound in toilet uses. The investigation of consciousness showed that women had high ratio to care an excretion sound out of home and performed twice or more flushing to absorb excretion sound and the use of it was effective in restraint of this multiple flushing. The investigation of the actual condition showed that the mean flushing number of times per once toilet use was 1.74 times before installing of a flush sound jamming device and 1.08 times after installing of it, and the flushing number of times per person per use decreased 0.66 times by installing that device.
View full abstract
-
Naoji MITSUMOTO, Yoshinori KOMATSU
Article type: Article
Session ID: A-18
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We have been investigating toilet in convenience stores by placing as a new type of public toilets. One of the results was the low use rate of toilets on female compared with that on male, however the reason was not made cleared yet. So, we investigated the toilet use aimed on female according to the toilet styles with the aim of making cleared what kind of toilet is prefered to women. It was shown that women prefer toilet separated by sex from the result of the use rate and the congested rate.
View full abstract
-
Mari MOROKAWA, Kanako TOYOSADA, Yasutoshi SHIMIZU, Kuniharu KOJIMA, Hi ...
Article type: Article
Session ID: A-19
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We investigated the consciousness and the actual condition about the recent toilet use by questionnaire. As a result, the mean excretion number of times were 1.1 times for defecation and 5.2 times for urine, mean washing number of times were 2.5 times for defecation, 4.7 times for urine and 0.4 times for cleaning, per person per day. It became clear that the excretion number of times tended to increase a little with aging, and this number in home or outside had a significant difference by the occupation.
View full abstract
-
Ryota YANASE, Hiroyuki KOSE
Article type: Article
Session ID: A-20
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The purpose of this study is to investigate the actual situation of using sanitary fixtures except for the house. The authors carried out a questionnaire to 409 high school students or over. The results found in this study are summarized as follows; a) people using the booth not only discharge but also change their clothes and arrange their belongings, b) various acts in the washroom were confirmed, and it hinted the usefulness of installing the powder corner.
View full abstract
-
Hiroyuki KOSE
Article type: Article
Session ID: A-21
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
"Decision of Fixtures Requirement" in the SHASE-S206 technology guide is used in the field of the architectural design, and the importance is high. In the future, the development of the technology guide which can be applied to large scale of the building and use of the toilet of individual building, all buildings use. In the revision of future technology guide, it is necessary to present the more general purposive calculation method as SHASE, while present calculation method is followed. Then, in this study, the calculation program of fixture requirement with the high generality was developed, and the calculation result was compared with the result of the current technology guide.
View full abstract
-
Tsuyoshi UENO, Hiroyuki KITAHARA, Toshiyuki MIYANAGA, Wataru URABE
Article type: Article
Session ID: B-1
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research aims at the development of a heat source characteristic model of air conditioner for cooling period, which is useful for energy-saving of cooling demand while keeping comfort of residents in residential building. This heat source characteristic model aims at the ratio of the theoretical efficiency and real efficiency of the heat source of the appliance. The model does not depend on the characteristic of the specific appliance; therefore it is applicable for various appliances. In this paper, detail of the modeling is described.
View full abstract
-
Hiroyuki KITAHARA, Tsuyoshi UENO, Toshiyuki MIYANAGA, Wataru URABE
Article type: Article
Session ID: B-2
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This research aims at the development of a heat source characteristic model of air conditioner for cooling period, which is useful for energy-saving of cooling demand while keeping comfort of residents in residential building. In this paper, an experiment for grasping characteristic of air conditioner for cooling period and the results of comparing simulation values with measured values are described. Monitored data and estimated data were almost equivalent.
View full abstract
-
Kenji UEDA, Yoshie TOGANO, Yoshiyuki SHIMODA
Article type: Article
Session ID: B-3
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Estimating partial-load performance of centrifugal chiller is very important to operate a heat source system in high efficiency. In this paper, we show a method of calculating the partial-load performance for fixed-speed chiller and iiriable-speed chiller. The method is flamed by simple equations derived from thermodynamics and fluid dynamics of centrifugal compressor. The performance at various operations can be calculated by the method (partial-load ratio, cooling water temperature, chilled water temperature). Accuracy of the method is compared with measurement performance data. Furthermore, the method will be applied for a control board of chiller and a simple simulation which consists of Excel spreadsheets.
View full abstract
-
Saki TAKAYAMA, Yasunori AKASHI, Yasuhiro KUWAHARA, Kenji UEDA, Yoshie ...
Article type: Article
Session ID: B-4
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The simple performance evaluation tools which consist of Excel spreadsheets have been used. In this paper, we apply the calculation method of partial load performance of variable-speed chiller to the tool. The method is applied without modifying the structure of the tool, and accuracy of the tool is compared with measurement performance data. Furthermore, energy consumption of centrifugal chiller for business use building in summer is calculated by the tool, and compared with results of a conventional simulation model which is high accuracy. The differences between the tool and the simulation model are from 5 to 10%.
View full abstract
-
Yohei SHINO, Shigeki KAMETANI, Hisashi NAOI
Article type: Article
Session ID: B-5
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This simulation model is built to optimize a heat source system of a building due to reduce energy consumption and carbon dioxide emissions. We calculated heat load of a modeled office building and analyzed energy consumption and carbon dioxide emission with using various central and split air conditioning systems. Furthermore, it will be efficient model for energy saving of the building, and eventually, for reducing the heat island effect.
View full abstract
-
Masaya TACHIBANA, Masahiko UMETSU, Masamichi IWATANI, Gou NODA
Article type: Article
Session ID: B-6
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Due to the redevelopment plan, a demolition and new construction of the "Kyobashi 1 / 2-Chome DHC (District Heating and Cooling) Plant" has been examined. This paper summarizes outline of the temporary relocation work for the DHC and describes the optimization study for the DHC design on continuous assessment to fulfill the requirement of the newly installed DHC system serving to the redevelopment area.
View full abstract
-
Shohei OGATA, Ryosuke OKADA, Kimiya MURAKAMI
Article type: Article
Session ID: B-7
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, the energy-saving effect of the heat source water supply network using reclaimed water constructed in an existing urban area was analyzed. As a result of analysis, in a building, the energy-saving effect of the heat source system became about 15 to 20% at the maximum. Moreover, in the whole existing urban area, the effect in the case using the heat storage tank became 16.4%.
View full abstract
-
Shinya NAGAE, Yoshiyuki SHIMODA, Shiori TAKAMURA, Kenichiro WATANABE, ...
Article type: Article
Session ID: B-8
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The purpose of this study is to examine the most efficient operational control method in district heating and cooling system (DHC) which is renovated for energy efficiency implovement. The simulation model for the original and renovated plant was developed based on the equipment specifications of the original plant. The accuracy of this model is verified based on the comparison to the measured data in 2009. From the result of this study, it is found that the optimal operation of high-efficiency equipment and effective control of flow rate contribute greatly to energy efficiency improvement.
View full abstract
-
Shiori TAKAMURA, Yoshiyuki SHIMODA, Shinya NAGAE, Kenichiro WATANABE, ...
Article type: Article
Session ID: B-9
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Usually, district heating and cooling (DHC) plant is evaluated by its efficiency. However, the efficiency of the plant may be influenced by the heat load pattern or the temperature that is different in each DHC. If this influence is large, each DHC can't be compared only in efficiency. Therefore, the purpose of this study is to evaluate these influences quantitatively. In the last of this paper, the difference in three calculation methods of exhaust heat from combined heat and power was considered.
View full abstract
-
Hisataka KITORA, Hideharu NIWA, Yoshibumi SUGIHARA, Ryutaro KUBO, Masa ...
Article type: Article
Session ID: B-10
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The DHC system in the block 3 in Nakanoshima was planned to utilize thermal energy of river water. Heat source system of the DHC was extended by second stage construction in March 2009. This report outlines overview of the expanded DHC system and performance evaluation of operation in 2009.
View full abstract
-
Kimiya MURAKAMI, Ryosuke OKADA
Article type: Article
Session ID: B-11
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In Tokyo, the new institution concerning DHC system was founded. There, evaluation of the energy efficiency of a DHC system is very important. Proper evaluation of the efficiency of DHC system which utilize cogeneration especially is a subject. Therefore, in efficiency evaluation, the influence which the method of classifying the annual primary energy consumption of CGU into a generated electricity part and a waste heat part has was considered by this paper. Next, the domain selection system using a distribution coefficient was proposed.
View full abstract
-
Noriomi Okazaki, Kunio MIZUTANI, Hideyuki SATO, Hiroyuki NISHI, Daisuk ...
Article type: Article
Session ID: B-12
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This Paper reports the summary of the improvement in stability of Variable Water Volume Control for Primary Water System. Primary Water System is unsettled to changed heat load or number of operating heat source machine. We investigated method for improvement in stability of Variable Water Volume Control for Primary Water System. We suggested operating frequency is calculated by the accuracy of P-Q model. This method is practical use and useful by some experiments.
View full abstract
-
Sakae IWAI, Seiichi KITTA
Article type: Article
Session ID: B-13
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, we report the effects of energy saving to by Change of Supply Temperature of Chilled Water to Air-Conditioning System. Energy-saving effect is calculated by simulation. Simulation model in this case, power reduction due to chilled water temperature change is 6% or more and had enough energy savings. Determining how chilled water temperature, examined the proposal to set the temperature on a monthly basis and determined by measurement of load factor.
View full abstract
-
Mariko KAMIYA, Hideharu KOMODA, Masaya HIRAOKA
Article type: Article
Session ID: B-14
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Minimization of the energy during the operation of building is becoming an important issue to reduce the carbon dioxide emission worldwide. For this purpose, in the design process the energy consumption of several types of air conditioning systems should be examined in depth. Preliminary research conducted by authors indicated that the widely used central air conditioning system results in a lot of energy loss due to the spatially distributed different loads in a building. In this report, the multi-split type air-conditioning system that utilises water as a heat source with individually controlled plural water pumps is examined in view of total consumption of energy during a whole year.
View full abstract
-
Hideki YAMAMOTO, Hajime AKAHANE, Katsuhiko TANAKA, Masashi MOMOTA, Tsu ...
Article type: Article
Session ID: B-15
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
For further spread expansion, high promotion and development for efficiency will be demanded strongly, in future. At first we arranged it and analyzed stocktaking and past knowledge and we confirmed the promotion of efficiency element for the future, on this paper. Furthermore, We tested it about these each elements and inspected the technical possibility for efficiency use from the result.
View full abstract
-
Satoshi YANO, Takashi SINOJIMA, Kenji HIDAKA, Nobuyuki TORII, Yoshihir ...
Article type: Article
Session ID: B-16
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Output side of air-conditioning system is connected to FCU. We expected the cold water returned from FCU as cascading use. By it, in the summer, it realized large difference of temperature running at 13 ℃ at the maximum. In the winter, it realized the collection of the outside air reduced the source production heat capacity. In addition, it realized outside air-conditioning system supply air temperature 16℃ without any heat source.
View full abstract
-
Kenji HIDAKA, Nobuyuki TORII, Satoshi YANO, Takashi SINOJIMA, Kazuki D ...
Article type: Article
Session ID: B-17
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper is regarding the maximum efficiency of ice thermal storage system with large temperature difference. We focus on the system design and operation by illustrating the actual data at Aeonmall kusatu. Each chilling unit operated at 70% partial load where it shows the highest efficiency. And the gap from the actual load was covered with ice melting capacity. By tuning up the system operation schedule seasonally, the average COP of the primary chilling system through a year can be raised up to 4.02 which is higher than other similar systems.
View full abstract
-
Yoshihiro MATSUMOTO, Takashi SHINOJIMA, Satoshi YANO
Article type: Article
Session ID: B-18
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper is a design of Ice thermal storage system with large temperature difference and the verification of results of performance with operating this system. OAC FCU and Air conditioning of the secondary side connected in series. We speak the necessary air conditioning plumbing and automatic attention to operate this system. And we examined the influence that the characteristic of OAC and FCU gave a system. As for the system setting, FCU cold water exit temperature is important.
View full abstract
-
Takafumi NISHII, Akihiko YOSHIZAWA, Tadahiko IBAMOTO, Hajime AKAHANE, ...
Article type: Article
Session ID: B-19
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Focusing a transportation energy reduction of the ice storage system, we had proposed the system which has the vertical ice storage tank. However, because this system was structurally uneasy, we proposed a consolidated vertical ice thermal storage tank that distributed the heat storage tank. On this paper, we examined the thermal quality by using a consolidated vertical ice thermal storage tank. The effectiveness of the flange connection was able to be confirmed by this research, and to maintain chilled water (supply) under seven degrees within the condition of peak heat load. Moreover, it was confirmed that a ultrasonic meter could detect the state of full charging by sensing the distance between bottom of the tank and ice.
View full abstract
-
Junya TANAKA, Motoi YAMAHA, Akihiro OSAWA, Hisashi FUJITA, Tsuyoshi IT ...
Article type: Article
Session ID: B-20
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
An analysis of thermal characteristics of a storage tank containing phase change material with middle temperature melting point was conducted. We made experiments that examined influence of temperature and flow rate of the tank inlet using a mixture of paraffin waxes of melting temperature of 16 ℃. We found that input temperature should be 3 to 4 ℃ lower than the melting temperature and lower flow rates resulted in preferable outlet response.
View full abstract
-
Motoi YAMAHA, Junya TANAKA, Akihiro OSAWA, Hisashi FUJITA, Tsuyoshi IT ...
Article type: Article
Session ID: B-21
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
A simulation model for thermal energy storage tank using phase change material with moderate melting temperature was proposed. The model consists of one-dimensional heat transfer equation together with enthalpy method for phase change. Stratification was taken into account by two zone mixing model. Comparison of experimental results showed good agreement and system simulation was conducted to validated performances of the tank.
View full abstract
-
Kenji SUKEMIYA
Article type: Article
Session ID: B-22
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The heating storage capacity of existing thermal storage water tank which space is small can be increased by installation of the latent heat thermal storage system. In the facility design including design of the multi tank connection type thermal storage water tank, if the effect to use the latent heat thermal storage can be understood by the simulation beforehand, it is significant. The computing models of coagulation and dissolution analysis, and the model of thermal storage water tank are combined, and the result of the behavior analysis of the multi tank connection type thermal storage water tank is reported in this paper.
View full abstract
-
Kenichi HASGAWA, Shin-ichi MATSUMOTO, Shuzo MURAKAMI
Article type: Article
Session ID: C-1
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The penetration rates of several energy-saving technologies for houses from 2010 to 2050 were forecasted by means of questionnaire survey on Delphi method. The Delphi method is a forecasting method which relies on experts' judgements. In this paper, ten kinds of technologies such as housing equipment for space heating and demand hot water, PV, HEMS and so on were investigated to the experts working on home supply. Investigated results of these technologies penetration rates should be useful to the development of scenarios for a Low-carbon society.
View full abstract
-
Matsunori NARA
Article type: Article
Session ID: C-2
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The method to generate electricity by introducing the hydrogen produced with the wastewater and waste into the fuel cell is developed. We did a basic experiment study to manufacture hydrogen by making the sugar manufacture waste fluid of an organic wastewater a substrate and using the purple nonsulphur bacterium. The relation among the substrate quantity, the photosynthesis bacillus growth rate, and the hydrogen production that influenced the efficiency of this hydrogen manufacturing system as a result of doing the case study of the batch type was able to be shown.
View full abstract
-
Makoto SATO, Yuhei KOBYASHI, Hiromi KOMINE
Article type: Article
Session ID: C-3
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, the selection procedures of renovation measures remarkable as sustainable design for timeworn school in the Kawasaki city were developed. This paper describes a database to organize schools and overview of school performance. In addition, also described in the simulation results validate the energy conservation at a school renovation.
View full abstract
-
Yuhei KOBYASHI, Makoto SATO, Hiromi KOMINE
Article type: Article
Session ID: C-4
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The relations between environmentally conscious improvement techniques and various characteristics of these techniques were analyzed from the view of renovating timeworn schools and improving classroom environment. The flowchart for planning environmentally conscious improvement techniques to particular school property was suggested. The trial of planning procedure according to this flowchart for a certain elementary school established in Kawasaki city was carried out in order to verify the planning system.
View full abstract
-
Yasunobu ASHIE, Takao SAWACHI, Yasuo KUWASAWA, Masato Miyata, Yoshimas ...
Article type: Article
Session ID: C-5
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Hydrogen does not produce carbon dioxide (CO2) when burned and is hence regarded an ideal clean energy source. This study investigates the CO2-reduction effects and cost-effectiveness of a hydrogen society into which hydrogen stations and pipelines are assumed to be extensively introduced. Part 1 gives an overview of the objectives of this study. Then the methods of simulating energy use in a district heating/cooling system and individual heat source system are described. Finally, methods of evaluating annual cost and CO2 reduction cost of introducing hydrogen stations to the entire district are explained.
View full abstract