In this research, it aims to understand the limit of the length of the horizontal fixture branch in the gravity drain of the super-water saving closet that becomes a problem when the free plan in water circumference making is achieved in SI house. And it compared the closet of washing volume of water 6L and 8I.
View full abstract
-
Yuji TAKAHASHI, Masayuki OTSUKA, Hideaki HOSHINA
Article type: Article
Session ID: A-23
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The report proposes a method (hybrid drainage system) by using of gravity drainage system and pressure pumping drainage system together with using pressure feed pump unit which can supplement the decrease in gravity drainage transfer ability. And to clarify some considerations of piping design by evaluating the performance of this method.
View full abstract
-
Shin KOUNO, Masayuki OTSUKA, Zhe Zhang, Tsubasa UENO
Article type: Article
Session ID: A-24
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report propose a prediction method for drainage performance, which use the evaluation indices acquired by measuring a pipe pressure variation and an air flow rate when air-admittance valves are installed in a locations along the horizontal fixture drain branch of a drainage stack system. And examines how the change of the negative pressure value and the positive pressure value of pipe pressure affects the drainage performance.
View full abstract
-
Tsubasa UENO, Masayuki OTSUKA, Zhe Zhang, Shin KOUNO
Article type: Article
Session ID: A-25
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report uses the evaluation indices acquired by measuring a pipe pressure variation and an air flow rate when air-admittance valves were installed in two locations along the horizontal fixture drain branch of a drainage stack system. And examines how the change of the negative pressure value and the positive pressure value of pipe pressure affects the drainage performance when the number of locations for installing air-admittance valves is increased.
View full abstract
-
Zhe Zhang, Masayuki OTSUKA, Shin KOUNO, Tsubasa UENO
Article type: Article
Session ID: A-26
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report examines how the change of the negative pressure value and the positive pressure value of pipe pressure affects the drainage performance when the number of locations for installing air-admittance valves is increased. The main items to be examined are as follows: Understand the change of pipe pressure and air flow rate in relation to the change of the number of air admittance valves . Examine a workaround for the positive pressure which is important mainly for defining drainage performance and determine the threshold limit value of drainage performance. Propose and verify the piping model for prediction of drainage performance when multiple air-admittance valves are installed.
View full abstract
-
Takayuki TOYAMA, Kyosuke SAKAUE, Yoshinori TANAKA, Shinji SHIBATA, Shu ...
Article type: Article
Session ID: A-27
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, we tested the capacity of the two types of drainage stack systems connected to the Super water-saving toilets which uses 4.8-liters of water per flush, and also tested the effect of air pressure changes in pipe on trap seal water. Following the previous report, based on these results we report on the adaptation of the super water-saving toilets in the apartment houses.
View full abstract
-
Hirofumi KAGAMI, Masayuki OTSUKA, Hideaki HOSHINA, Keisuke HIRAI
Article type: Article
Session ID: A-28
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In recent years, water saving closet is moving ahead. So that, This thesis deals with the comparison of the influence on drainage capacity of super-water saving closet uses 5-liters and every kind of super-water saving closet. In addition, Accumulating dates of the experiment is the purpose of this thesis too.
View full abstract
-
Gen MORIMURA, Kyosuke SAKAUE, Hana KURIYAMA, Motoyasu KAMATA
Article type: Article
Session ID: A-29
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The purpose of this study is to develop the simple test method of trap performance using simple testing devises. We experimented on the method to apply to opaque traps using the hydrograph by the seal-break-test, and obtained the result which this method was effective for the pipe traps, but it developed that we needed be improved for the partition traps more. And we examined the anti-pressure performance of Super Saving Water Type WC by this method.
View full abstract
-
Shigekazu OKAUCHI, Kyosuke SAKAUE, Hirofumi YAGI
Article type: Article
Session ID: A-30
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The examples that WC's traps break super high-rise apartment houses are sporadic recently. It is hard to think the phenomenon of this seal break to have occurred because of only the induced siphonage based on an atmospheric pressure. We assumed that indoor pressure influenced this phenomenon and examined the influence by actual measurement.
View full abstract
-
Hideyuki MARUYAMA, Michihiro KOIKE, Koji SAWADA, Hideo YAMAGA, Kyosuke ...
Article type: Article
Session ID: A-31
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
A siphonic drainage system is a kind of slope-less drainage system using small diameter pipes. We examine a method to lay the sink of the kitchen by siphonic drainage. When we wash with running water, a problem that water stays on a trap occurs. Therefore we use the expansion air bag to solve the problems. As a result of experiment, we understand that this technique is effective and investigated the demanded performance of the bag.
View full abstract
-
Yu Aida, Kyosuke SAKAUE, Hideo YAMAGA, Hideyuki MARUYAMA, Michihiro KO ...
Article type: Article
Session ID: A-32
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
A siphonic drainage system is a kind of slope-less drainage system using small diameter pipes. This paper verified drainage noise by the siphonic drainage system with a temporary tank combined with floor-preceding double-floor. The result showed that the noise of the siphonic system was larger than the conventional drainage system. The result also indicated a possibility of reducing the siphonic system's noise by preventing under-floor noise-propagation from its tank.
View full abstract
-
Yoshifusa NISHIMURA, Kyousuke SAKAUE, Hideo YAMAGA, Hideyuki MARUYAMA, ...
Article type: Article
Session ID: A-33
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
A siphonic drainage system is a kind of slope-less drainage system using small diameter pipes. We have already reported its sufficient drainage ability, but its maintenance performance is needed to be verified for practical use. In this paper, pipe-cleaning methods for conventional apartment were tested on the siphonic drainage system. Also, we conducted an experiment and proposed artificial fouling for further pipe-cleaning test on the system.
View full abstract
-
Yuki TANAKA, Kyosuke SAKAUE, Takehiko MITUNAGA
Article type: Article
Session ID: A-34
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aimed to accumulate the basic data concerned about the design of the siphonic drainage system. We carried out the verification experiments about the flow characteristic in the following circumstances in the cases that the convex rising elbow pipe was connected to the outlet part of the horizontal drain pipe or it wasn't connected. And in addition, we also examined on experiment about the effectiveness of the formula derived from the Bernoulli's equation to calculate the pressure in the pipes when the siphon effect has been started.
View full abstract
-
Katsumi HONDA, Kyosuke SAKAUE, Hideo ISOZAKI
Article type: Article
Session ID: A-35
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, we examined the discharge characteristics and performance of the siphonic drainage system with the long horizontal drainage pipe for a kitchen sink with a disposer by the field experiment for the purpose of practical uses.
View full abstract
-
Susumu TAKACHI, Kaori KOBAYAKAWA, Kazuya KOMINAM, Takashi OKAZAK
Article type: Article
Session ID: A-36
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The trend investigation result of various interceptors in the outline of the investigation and grease-interceptor was arranged. As a result, the current state and the tendency to the situation to date to the installation realities of grease-interceptor along with worth of an investigation result were able to be understood four times.
View full abstract
-
Kaori KOBAYAKAWA, Susumu TAKACHI, Kazuya KOMINAMI, Takashi OKAZAKI
Article type: Article
Session ID: A-37
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We investigated the trend of the sale amounts of oil-interceptors, plaster-interceptors and hair-interceptors, which companies of Interceptor Industrial Institute of Japan have sold. As the result, we was able to grasp the current conditions and the tendency of the actual setting situation of each interceptor.
View full abstract
-
Kazuya KOMINAMI, Susumu TAKACHI, Kaori KOBAYAKAWA, Takashi OKAZAKI
Article type: Article
Session ID: A-38
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper proposes the method of examining the performance from recent experimental results about oil-interceptors. According the results, the oil keeping performance against to rain water and a large amount of oil inflow clearly can manipulate by using a few types of internal mechanics of oil-interceptors. The test condition and the measuring method for which good retention efficiency on sand and oil and the rise in water level are presented here. As a result, the relevant selection of oil-interceptor that has the proper capacity and mechanics becomes available.
View full abstract
-
Hiroyuki KUSAKARI, Keita FUKUI, Seishi OKADA, Hitoshi AKAI, Nobuharu M ...
Article type: Article
Session ID: A-39
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In order to investigate the effect of an add-on purifier for the grease interceptor at the experiment with the condition when adding pure lard to tap water, the most effective result was using the purification unit which was composed with the ozone or diffused air process and added enzyme material, and the reduction quantity was 5% of the total.
View full abstract
-
Isao NAGANUMA, Kyosuke SAKAUE, Toshihisa MATUSHIMA, Yoshio IKEDA, Taka ...
Article type: Article
Session ID: A-40
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is necessary to aim at the welded joint durability and corrosion resistance improvement to construct the high endurance piping system, and it is necessary to prevent the weld being oxidized. To obtain durability and corrosion resistance in the weld, the criteria sample of the oxidized scale in the weld was made, and the present study expressed numerically and evaluated the color.
View full abstract
-
Daisaku MURAKI, Toshihisa MATUSHIMA, Ichirou NAGUMO, Yoshio IKEDA, Tak ...
Article type: Article
Session ID: A-41
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We built the stainless steel plumbing of approximately 40m and welded it while pouring back shielding gas into the piping. Then we inspected it whether a weld could get white skin and evaluated coloration parts of an oxidation scale formed on the weld by the color difference. In addition, we suggest the construction points of the automatic welding in sites.
View full abstract
-
Kazuharu TSUNETOU, Kyousuke SAKAUE, Hiroshi IIZUKA, Kazuyuki NAKANO, T ...
Article type: Article
Session ID: A-42
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
For general-purpose synthetic rubber used in stainless steel pipe fittings, performance was evaluated by applying heat aging test. The results from the test are shown below. 1) Black powder, almost did not occur. 2) Some dumbbell specimens were deposited Bloom. 3) The antioxidant, decreased slightly. 4) Tensile strength and elongation also decreased with the longer test time.
View full abstract
-
Hiroshi IIZUKA, Kyousuke SAKAUE, Kazuharu TSUNETOU, Kazuyuki NAKANO, T ...
Article type: Article
Session ID: A-43
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
To evaluate the durability test, a dumbbell test piece made of synthetic rubber in general, the concentration of residual chlorine test solution was adjusted, will be held immersion. 1) The amount of black powder deposition, processing time will be high density, are now rank 05 rating. 2) Changes in hardness and tensile and elongation, the material is different. 3) The processing time will be high levels of residual chlorine contained in the test solution, and voids and cracks. 4) The percentage of residual antioxidant, showed different trends depending on the material.
View full abstract
-
Tsutomu NAKAMURA, Kyousuke SAKAUE, Hiroshi IIZUKA, Kazuharu TSUNETOU, ...
Article type: Article
Session ID: A-44
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this paper, citing fitting stainless steel pipe that is used, the results showed that the examined life of synthetic rubber used to prevent leakage. 1) The water supply system,, the life of synthetic rubber is around 50 years. 2) System in the fire water must be replaced frequently, life as much as synthetic rubber is expected to Water System. 3) The hot water system, the reference is the life of synthetic rubber-up to 15 are estimated to be about 20 years. 4) The chlorine is injected into the system as well water, the life of synthetic rubber is estimated to be around 30 years.
View full abstract
-
Michihiro KOIKE, Kyosuke SAKAUE, Sadanori KODERA, Shigeyuki MATSUMOTO, ...
Article type: Article
Session ID: A-45
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The piping systems in apartment houses are constructed by pipes, pipe fittings and valves mainly. We can reduce the stop time and the accompany works to occur because of maintenance by facilitating maintenance in the stainless steel piping. We suggest the stainless steel piping system realizing improvement for the service life using the easy maintenance method for pipe fittings and valves.
View full abstract
-
Naoto OBARA, Kyosuke SAKAUE, Michihiro KOIKE
Article type: Article
Session ID: A-46
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
The life of conventional piping system depends on corrosion and deterioration. The long-life-piping system gives more economical advantage and more CO_2 emission advantage than the conventional piping system. This paper describes the results of evaluation the life cycle cost and the life cycle CO_2 of all-stainless steel piping system in apartment houses by LCC (life cycle cost) and LCCO_2 (life cycle CO_2) in the period of 200 years.
View full abstract
-
Hideo YAMAGA, Hidekazu FUJIMOTO, Masayuki OTSUKA, Shinichi CHIKAZUMI, ...
Article type: Article
Session ID: A-47
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to establish an evaluation method on renewal of common drainage stack and propose a new renewal method. In a pipe-space mock-up, a renewal method using a slide coupling was tested. The operation time and space required for the renewal was verified, and its evaluation method was studied.
View full abstract
-
Youzou KAKO, Hidekazu FUJIMOTO, Masayuki OTSUKA, Shinichi CHIKAZUMI, H ...
Article type: Article
Session ID: A-48
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to establish an evaluation method on renewal of common drainage stack and propose a new renewal method. In succession to the previous paper, a renewal method using interchange coupling was verified. From the result, an evaluation method and space required for renewal were clarified, and building plan for easy-renewal was proposed.
View full abstract
-
Shinichiro GOTO, Toshihisa MATSUSHIMA, Takao FUJIWARA
Article type: Article
Session ID: A-49
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Evaluation of the function of an immediately hot water loop plumbing system. It experimented immediately by the practical model piping of the loop piping that had the hot water function, and discharge characteristics when circulating and the pressure loss were verified. The best piping design technique was considered as a result.
View full abstract
-
Ryosuke ISHIBASHI, Motoyasu KAMATA, Toshihisa MATSUSHIMA
Article type: Article
Session ID: A-50
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
I reports about Anti-corrosion coupling for feeding pipe. Method of evaluating anti-corrosion performance for that coupling has only method for new coupling. I propose Method of Anti-corrosion performance evaluation of coupling for feeding pipe.
View full abstract
-
Toshihiro YAMATE, Minoru HACHIYA, Teruyasu MORITA, Tomonao MITSUMORI, ...
Article type: Article
Session ID: A-51
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In the repair construction work etc. of the buildings the wet fire piping and the wet sprinkler piping are cut by the fusion and grinder. In their cases, the phenomena of the cutting part's igniting are reported. It is possible to depend on the hydrogen generated in piping as their causes. The reproduction experiment was done filling tap water in the galvanic couple of the stainless flexible tube joint and the galvanized steel pipe. Moreover, the galvanic couple of the stainless steel plate and the zinc plate was soaked in the airtight container that filled tap water, and the pressure change in the container was examined. As a result of the experiment, the generation of the hydrogen gas was confirmed. It reports on the outline as follows.
View full abstract
-
Michinori KUBOTA, Kazunobu SAGARA, Toshio YAMANAKA, Hisashi KOTANI, Yo ...
Article type: Article
Session ID: B-23
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In this study, a detection method of dead water zone for water thermal energy storage tank of multi-connected complete mixing type is proposed. A simulation using a physical model under ideal conditions is conducted with measured temperature and flow rate, and measured data is compared with results of the simulation in order to detect dead water zone in the detection method. The detection method was applied to a real thermal energy storage system and the dead water zone was detected.
View full abstract
-
Takuya FUJIMOTO, Yohei YAMAGUCHI, Tomo OKAMURA, Yoshiyuki SHIMODA
Article type: Article
Session ID: B-24
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
A large-scale increase in the electricity generation capacity of PV is expected to disturb the stability of the electricity grid system. This paper analyzes the capacity to reduce the surplus electricity by shifting the hours during which heat pump water heaters installed in residential houses are operated. First we evaluated the effect while assuming a detached house with a family. We then estimated the effect for the residential sector of Osaka city while assuming that PV and heat pump water heater would be adopted by 40% of the detached house stock of the city.
View full abstract
-
Masashi YAMAGIWA, Yuka ASANO, Kazunobu SAGARA, Toshio YAMANAKA, Hisash ...
Article type: Article
Session ID: B-25
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
It is difficult to realize the actual condition of a thermal energy storage by outdoor air which uses the building structure and furniture as the heat storage material. However, some of those heat storage materials have been unconsidered on reported heat transfer simulation. In order to improve the system simulation, this paper presents a new calculation model for beams which have almost the same heat capacities as furniture and shows the effect of heat storage materials along the air flow path in the building thermal energy storage system.
View full abstract
-
Yifei YU, Takeshi IWATA, Kazunobu SAGARA, Toshio YAMANAKA, Hisashi KOT ...
Article type: Article
Session ID: B-26
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
To design a temperature-stratified water TES tank of high performance, it is very important to decide the design of diffusers used as inlet and outlet, depth of water in the tank, flow rate, temperature of inlet, and so on. To establish the most suitable operation of water TES tank, it is beneficial to use CFD for evaluating the thermal storage performance. In this paper, it is aimed to validate CFD. The result of CFD calculation was compared with the experimental data, and it was found that the temperature profile obtained from the CFD calculation corresponds almost to the experimental date.
View full abstract
-
Yuta KOTAJIMA, Masahiro OTOMO
Article type: Article
Session ID: B-27
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
In the heat source system of a water heat storage method comprised of only an electric heat source machine, we planned re-design, environment load reduction to aging update. It reports on a outline of the re-design and the effect of the energy reduction by data at the time of the completion.
View full abstract
-
Hideharu NIWA
Article type: Article
Session ID: B-28
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
New railway Nakanoshima-line was inaugurated in Osaka Nakanoshima area, and four new under-ground located stations were opened in 2008's autumn. At three of these stations, thermal energy of river water is utilized for heat pump system with ice storage as unused energy for energy saving and heat island relaxation. In this paper outline of the ice storage system using thermal energy of river water and results of operation performance evaluation in 2009's summer are introduced.
View full abstract
-
Kazuki YAJIMA, Masashi KAWANO, Yuzo SAKAMOTO, Ryuji YANAGIHARA, Masayu ...
Article type: Article
Session ID: B-29
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper reports the result of measurement of energy consumption in a central AC system in the University of Tokyo. Effect of the AC system improvement was confirmed. On the other hand, there is a problem that air-conditioning equipment deteriorated. This paper analyze an additional energy savings by system simulation by LCEM.
View full abstract
-
Ryuji YANAGIHARA, Masashi KAWANO, Yuzo SAKAMOTO, Masayuki ICHINOSE, Ka ...
Article type: Article
Session ID: B-30
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper reports the result of investigation and measurement of energy consumption in the University facilities. The facilities of medicine and a pharmacy and the hospital was much energy consumption. Therefore, we performed CO2 reduction by improving the operating based on a measurement result and introduction of Heat-recovery turbo chiller in University Hospital.
View full abstract
-
Masashi KAWANO, Ryuji YANAGIHARA, Yuzo SAKAMOTO, Hiroyuki MURAYAMA, Su ...
Article type: Article
Session ID: B-31
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This paper reports the result of measurements and Investigation of the Multi-Spiilit Air-Conditioning systems in the University of Tokyo. From these results, we understood that the capacity of the equipments were a large tendency. Therefore, we performed examination about reasonable capacity and proposed the renewal method as TSCP measures.
View full abstract
-
Hiroyuki MURAYAMA, Sumio SHIOCHI, Masashi KAWANO, Ryuji YANAGIHARA, Yu ...
Article type: Article
Session ID: B-32
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We investigated operational status in a multi-split air-conditioning system in the University of Tokyo. We inferred an annual thermal load from the measurement capacity of the system. Using the inferred thermal load as an input condition, we carried out annual energy simulations by LCEM and evaluated energy saving effect of renewal of the system, change of evaporating temperature and change in size of the system.
View full abstract
-
Yuuji MIYAJIMA, Hiroshige KIKUCHI, Takanari MIZUSHIMA, Hideo HANAOKA
Article type: Article
Session ID: B-33
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
Chilling units are driven all year round in industrial plants that have clean rooms and buildings that have data centers, because the inside cooling load of these institutions is large. An earlier report reported that we developed an optimizing control system of free cooling system with open cooling tower and heat exchanger. In this report, cooling water module that is able to produce the chilling water and the cooling condenser water was proposed. After setting up the test equipment, cooling capacity was examined. It was found that the cooling capacity of chiller operation is higher than the free cooling operation.
View full abstract
-
Kazuki YAMADA, Itaru MURASAWA, Masataka HOSOYA
Article type: Article
Session ID: B-34
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report presents the examination on design process and the measurement results of the heat sources with free cooling system operated automatically by the controller for heat sources in production factory. Based on measured data, the effectiveness of the heat sources with free cooling system was confirmed by simulation.
View full abstract
-
Kazutaka TERAO, Yasuhiro HAMADA, Takanori SUDA, Shunsuke IGARASHI, Kat ...
Article type: Article
Session ID: B-35
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to develop a hybrid energy buffer system for residential combined heat and power. Firstly, the effect of residential fuel cell combined heat and power systems was evaluated. Secondly, we propose the hydrogen storage alloy and the electric double layer capacitor as a energy buffer, and the effect of energy supply systems with each buffer was evaluated.
View full abstract
-
Yuuki ABE, Yoshiharu ASANO, Hideki TAKAMURA, Akiya OZAWA
Article type: Article
Session ID: B-36
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
We measured the detached house that installed a gas engine cogeneration system (GE-CGS) and a solar photovoltaic system (PVS). We measured the energy consumption of GE-CGS and the production of electricity of GE-CGS and PVS, as well as the amount of hot water and the quantity of heat supplied by GE-CGS. Then, we calculated the primary energy consumption and CO_2 emissions of the target all-electric house. We compared the primary energy consumption and CO_2 emissions of two houses. We found that the target house (GE-CGS+PVS) could reduce primary energy and CO_2 emissions.
View full abstract
-
Kiyotaka TAKEDA, Ryuichiro GOTO, Mitsuru NAKAMURA, Yasuhiro HAMADA, Ke ...
Article type: Article
Session ID: B-37
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to verify the effectiveness of optimum utilization of residential combined heat and power systems in cold regions for energy conservation. The outline is shown introducing the system and experimental condition. Operation results and primary energy reduction on representative weeks are shown and results on a space heating period are shown.
View full abstract
-
Ryuichiro GOTO, Mitsuru NAKAMURA, Kiyotaka TAKEDA, Yasuhiro HAMADA, Ke ...
Article type: Article
Session ID: B-38
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This report describes the evaluation concerning the performance of residential combined heat and power systems of fuel cells (SOFC) in the experimental house. First, the outline is shown about the system itself and experimental condition. Secondly, operation results are shown. And, the effects of the primary energy reduction are evinced.
View full abstract
-
Takuya MURAI, Yasuhiro HAMADA, Keita AMAZAWA, Katsunori NAGANO, Ryuich ...
Article type: Article
Session ID: B-39
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
This study aims to verify the effectiveness of optimum utilization of residential combined heat and power systems in cold regions for energy conservation. The numerical simulations concerning optimum utilization of residential combined heat and power systems were carried out, their optimum operation conditions and the effects of the primary energy reduction were evinced. In order to verify the availability of power and heat supply system that uses the CHP, we carried out analyses on characteristics of energy demand and the ratio of heat to power.
View full abstract
-
Kazumichi ARAKI, Kenya TAKAMURA, Atsushi AKISAWA, Takao KASHIWAGI, Tak ...
Article type: Article
Session ID: B-40
Published: August 12, 2010
Released on J-STAGE: August 31, 2017
CONFERENCE PROCEEDINGS
FREE ACCESS
To make CGS equipment plan, authors propose to make an exquisite simulation program, and to combine this with Particle swarm optimization. In this paper, CGS equipment plan of existing DHC is evaluated by using this technique. It is shown that the total error of a linear approximation is about ±5%. The effect of the part load performance of the equipment is shown. Efficiency changes most as the temperature of cooling water changes.
View full abstract