When a differential transformer having a high linearity is designed, there are so many conditions to consider that it is very difficult to correctly induce overall conclusions with only a few experiments under particular conditions. This problem is solved in this paper as follows:
1) Differential transformers are divided into two classes, two sectional type and three sectional type.
2) Designing condition is decided for constant primary impedance on each type.
3) Secondary coil is reasonably arranged by checking magnetic flux distributions.
4) Linear range is extended by means of feedback compensation including the connected circuit.
Obtained through the above study are the excellent differential transformers suitable for many conditions and yet have such a wide linear range as 30-40% of their length.