The LNG secondary pumps in LNG regasification terminal used to be cooled down by arranging
temporary pipe system and controlling its valves manually and discontinuously based on
experience of the operators. However, this processes increased variation of operations quality and
a risk of LNG leakage due to repetitive thermal stress on the temporary pipe system. In order to
solve these problems, an orifice is attached in the temporary pipe system, diameter of which is set
for cooling down continuously without manually controlling the valves. This improvement was
confirmed to be effective and contribute to safer operations by the verification test