Special Section on Recent Development of Electro-Mechanical Devices — Papers selected from International Session on Electro-Mechanical Devices (IS-EMD2010) and other research results —
-
Noboru MORITA
2011 Volume E94.C Issue 9 Pages
1349
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
-
Tetsuya ITO, Shigeru OGIHARA, Yasuhiro HATTORI
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1350-1355
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In recent years, there has been increasing demand to miniaturize wiring harness connectors in automobiles due to the increasing volume of electronic equipment and so on. With this demand, contact failure caused by the fretting corrosion seems to become a serious problem in the future. In this report, three-dimensional observations using Focused Ion Beam (FIB)-SEM method have been made for tin plated fretting contacts before and after the contact resistance increase with tin plating thickness 5µm. With these observations, the three dimensional structural transition from tin to tin oxide have been examined.
View full abstract
-
Jing LI, Zhiying MA, Jianming LI, Lizhan XU
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1356-1361
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Using a self-developed ASTM test system of contact material electrical properties under low voltage (LV), small-capacity, the current-frequency variable and a photoelectric analytical balance, the electric performance comparison experiments and material weighing of silver-based electrical contact materials, such as silver/tungsten and silver/cadmium oxide contact materials, are completed under LV, pure resistive load and small current at 400Hz/50Hz. The surface profiles and constituents of silver/tungsten contact material were observed and analyzed by SEM and EDAX. Researches indicate that the form of the contact material arc burnout at 400Hz is stasis, not an eddy flow style at 50Hz; meanwhile, the area of the contact burnout at 400Hz is less than that of 50Hz, and the local ablation on the surface layer at 400Hz is more serious. Comparing the capacities of the silver-based contact materials with different second element such as CAgW
50, CAgNi
10, CAgC
4 and CAgCdO
15 at 400Hz, no matter what the performances of arc erosion resistance or welding resistance, it can be found that the capacities of the silver/tungsten material is the best.
View full abstract
-
Laijun ZHAO, Zhenbiao LI, Hansi ZHANG, Makoto HASEGAWA
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1362-1368
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
To clarify how the occurrence of contact welding is related to the series of arc duration characteristics in consecutive make and break operations, electrical endurance tests were conducted on commercially available automotive relays, and the voltage waveforms of make and break arcs between the electrodes were recorded with LabVIEW. Experimental results indicate that welding may occur suddenly or randomly with increasing number of operations. A single arc or a group of make or break arcs with a long arc duration does not necessarily result in contact welding, but a group of longer make or break arcs within a narrow range of operation numbers can cause imminent contact welding (such an effect can be called the “group of longer arcing duration effect”). It is confirmed that contact welding may occur in both make and break operations, but the welding probability during make operations is much higher than that during break operations.
View full abstract
-
Yu-ichi HAYASHI, Yoshiki KAYANO, Takaaki MIZUKI, Hideaki SONE, Hiroshi ...
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1369-1374
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
When contact failure occurs in a connector in a coaxial high-frequency (HF) signal transmission line, it is well known that common-mode (CM) radiation occurs on the line. We focus on contact conditions in a connector causing such CM radiation. Experiments and simulations verify that CM radiation increases as the contact resistance increases. While the CM current strongly depends on the distribution pattern of contact resistances at a low resistance, the CM current does not depend on these pattern at a high resistance. Our results indicate that it is important to maintain a symmetrical distribution of contact spots whenever the number of such spots is four or more.
View full abstract
-
Xuerong YE, Jie DENG, Qiong YU, Guofu ZHAI
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1375-1380
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Generally, the failure rate of a sealed relay is regarded as a constant value, no matter where and how it is used. However, the failure processes of sealed relays won't be the same under different conditions, even for one relay, its failure rate also will be changed during operations. This paper studies the failure process of a kind of sealed relay by analyzing the variations of its time parameters. Among contact resistance and all those time parameters, it is found that closing gap time can indicate the failure process of tested relay very well. For the purpose of verifying this conclusion derived from time parameters, the contacts are observed by microscope after the tested relay failed. Both theoretical calculation result of contacts gap and photos taken by microscope show that the hypothetic failure mode derived from time parameters is reasonable. Based on the failure analysis, the paper also proposes a dynamic reliability estimation method with closing gap time.
View full abstract
-
Toru SUGIURA, Junya SEKIKAWA, Takayoshi KUBONO
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1381-1387
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Silver electrical contacts are separated to generate break arcs in a DC48V/6-24A resistive circuit. The transverse magnetic field formed by a permanent magnet is applied to the break arcs. A series of experiments are carried out for two different experimental conditions. One condition is a constant contact separating speed while the magnetic flux density is changed to investigate the shortening effect of the arc duration. Another condition is a constant magnetic flux density while the contact separating speed is changed to investigate the changes in the arc duration and the contact gap when the break arc is extinguished. As a result, with constant separating speed, it is confirmed that the duration of break arcs is shortened by the transverse magnetic field and the break arcs are extinguished when the arc length reaches a certain value
L. Under the condition of constant transverse magnetic field, (i) the arc duration is shortened by increasing the separation speed; (ii) the contact gap when the break arc is extinguished is almost constant when the separating speed
v is sufficiently faster than 5mm/s.
View full abstract
-
Naoya TAKESHITA, Junya SEKIKAWA, Takayoshi KUBONO
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1388-1394
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Break arcs are rotated with the radial magnetic field formed by a magnet embedded in the fixed contact. They are generated in a DC42V resistive circuit. The circuit current when the contacts are closed varies from 5A to 21A. The strength of a radial magnetic field for rotating break arcs changes. Arc duration is investigated. Then rotational frequency, arc length and Lorentz force when the periodic rotation of break arcs starts are analyzed to investigate the conditions required to rotate break arcs. The following results are obtained. The arc length
L when the rotational motion of the break arc starts is almost constant at a constant magnetic flux density with an increase in circuit current. The arc length
L decreases with an increase in the magnetic flux density of the radial magnetic field. The rotational motion of break arcs starts when the arc length
L reaches a certain value determined by magnetic flux density. Rotational frequency and Lorentz force increase linearly with an increase in circuit current.
View full abstract
-
Kiyoshi YOSHIDA, Koichiro SAWA, Kenji SUZUKI, Masaaki WATANABE
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1395-1401
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Recently, photovoltaic power systems and electric vehicles have been commonly used. Therefore, the importance of DC (direct current) switching is expected to increase in the near future. The authors have been examining a method of evaluating the electrode loss of AgNi contacts for an electromagnetic contactor with a medium DC load current at a resistive circuit. In this study, the arc energy and electrode mass changes were investigated in more detail. We carried out experiments of 100,000 operations for an electromagnetic contactor at a load current of 5A constant with a source voltage change from 100 to 160V. The arc duration, contact resistance, arc energy, and electrode mass changes were measured. As a result, the arc duration was found out increase with the source voltage. In addition, the stationary cathode mass change (loss) increased proportion only to the total arc energy. However, the stationary cathode loss per unit arc energy decreased at the highest source voltage.
View full abstract
-
Hongfei ZHAO, Xiaohua WANG, Zhiying MA, Mingzhe RONG, Yan LI
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1402-1408
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
An arc model has been applied in this paper to study the fundamental interruption environment of a 550kV SF
6 single-break tank circuit breaker. The full differential model takes into account of all important physical mechanisms and is implemented into a commercial Computational Fluid Dynamics (CFD) package, PHOENICS. The model takes a magneto-hydro-dynamics (MHD) approach and the governing equations are solved using the Finite Volume Method (FVM). Through the simulation, the flow velocity vector and mach number for capacitive current switching and short-circuit current breaking are analyzed, and flow dynamic characteristics are obtained. The simulation can provide helpful reference for the design of 550kV SF
6 single-break tank circuit breaker.
View full abstract
-
Yi WU, Hailong HE, Zhengyong HU, Fei YANG, Mingzhe RONG, Yang LI
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1409-1415
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
This paper focuses on the research of a new high-speed DC switch repulsion mechanism with experimental and simulation methods. Multi-physical equations reflecting the transient electromagnetic field, electric circuit, mechanical motion and material deformation are coupled in the calculation. For the reason of accuracy, skin effect and the proximity effect caused by the current in the coil are also taken into account. According to the simulation results, which indicate several key parameters severely affecting the mechanism speed, a high-speed DC switch repulsion mechanism is developed. By the test of mechanism motion, its average speed can be up to 8.4m/s and its mechanism response time is 250µs, which verifies the simulation results. Furthermore, during high speed motion the stress on the metal plate and moving contact is also discussed. It is noticed that the influence of the material deformation on the mechanical motion is very important.
View full abstract
-
Ruiliang GUAN, Hongwu LIU, Nairui YIN, Yanfeng HE, Degui CHEN
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1416-1421
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
With measuring the arc current, arc voltage and arc images, the high-current air arc commutation process across the separated electrodes was investigated. It shows that the existence of a short stable arc in the gap may increase the current commutation time. According to the energy balance of the arc column, the conditions to maintain the short stable arc were introduced and the effects of the current limiting resistance on the current commutation process were discussed.
View full abstract
-
Xingwen LI, Shenli JIA, Yimin YOU, Zongqian SHI
Article type: PAPER
2011 Volume E94.C Issue 9 Pages
1422-1426
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
The paper is devoted to the experimental study of the arc plasma characteristics in SF
6, N
2 and CO
2. To one flexible model of gas circuit breaker, short circuit experiments have been carried out considering the influence of contact gap (4-12mm), gas pressure (1-5atm), short circuit current (1-5kA effective value) as well as gas species particularly. During the experiments, the arc image, arc current and arc voltage are recorded by the high speed camera, shunt and voltage transducer, respectively. It demonstrates that to the above mentioned three kinds of gases, the arc radius and arc voltage increase with the short circuit current and gas pressure normally; however, under the same experimental conditions, N
2 arc holds the minimum arc radius and the maximum arc voltage, and the arc voltage of SF
6 arc is the lowest.
View full abstract
-
Yu-ichi HAYASHI, Takaaki MIZUKI, Hideaki SONE
Article type: BRIEF PAPER
2011 Volume E94.C Issue 9 Pages
1427-1430
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Recently, for electronic devices operating at high frequencies, the suppression of a high-frequency electromagnetic field of 1GHz or more has become necessary. We focus on a loose connector between a pair of electrical devices operating in the high-frequency band. Many electronic devices are used in living spaces, most of which are connected to one another. When a user connects two devices, achieving good contact only by finger tightening can be difficult. Accordingly, in this paper, considering the case where the tightening torque of a coaxial connector is insufficient, we analyze the effect of loose contact on electromagnetic field radiation from a transmission line.
View full abstract
-
Kazuaki MIYANAGA, Yoshiki KAYANO, Takashi KOMAKINE, Hiroshi INOUE, Tas ...
Article type: BRIEF PAPER
2011 Volume E94.C Issue 9 Pages
1431-1434
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In this paper, to clarify the thermal effect of the bridge for long lifetime contacts, the effects of heat conductivity on bridge break at different material contact pairs were discussed experimentally. To examine the relationship between the bridge and material, the electrode materials of the anode and the cathode were chosen as the same and the different material pairs in this experiment. Ag, AgPd
60 and Pd were chosen as the electrode materials, because Ag, AgPd
60 and Pd had the different thermal diffusivity. Firstly, the voltage waveforms in the bridge with different material pair were compared to the voltage waveform with the same material pair case. Secondary, the effects of heat conductivity on the break of bridge were discussed. In the results, the bridge voltage waveform depends on the electrode material at anode side. The length of the bridge at bridge break depends on the heat conductivity of the electrode material at anode side. This study provides the basic considerations on the thermal condition of the bridge break.
View full abstract
-
Makoto HASEGAWA
Article type: BRIEF PAPER
2011 Volume E94.C Issue 9 Pages
1435-1438
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In order to study the influences of contact opening speeds on arc extinction gap length characteristics, Ag contacts were operated to break DC inductive load currents from 0.1A to 2.0A at 14V with contact opening speeds of 0.5mm/s, 1mm/s, 2mm/s, 5mm/s and 10mm/s in a switching mechanism employing a stepping motor, and arc voltage waveforms were observed at each opening of the contacts. From the results, the average arc durations were determined at each current level under the respective contact opening speeds, and the average arc extinction gap lengths were calculated by multiplying the average arc duration value and the contact opening speed value. It was found that average arc durations showed no significant differences with increasing contact opening speeds. Thus, arc extinction gaps became larger at faster opening speeds in the inductive load conditions of this study.
View full abstract
-
Toru SEGAWA, Shinji MATSUO, Takaaki KAKITSUKA, Yasuo SHIBATA, Tomonari ...
Article type: PAPER
Subject area: Optoelectronics
2011 Volume E94.C Issue 9 Pages
1439-1446
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
We present an 8×8 wavelength-routing switch (WRS) that monolithically integrates tunable wavelength converters (TWCs) and an 8×8 arrayed-waveguide grating. The TWC consists of a double-ring-resonator tunable laser (DRR TL) allowing rapid and stable switching and a semiconductor-optical-amplifier-based optical gate. Two different types of dry-etched mirrors form the laser cavity of the DRR TL, which enable integration of the optical components of the WRS on a single chip. The monolithic WRS performed 1×8 high-speed wavelength routing of a non-return-to-zero signal at 10Gbit/s. The switching operation was demonstrated by simultaneously using two adjacent TWCs.
View full abstract
-
Pichai ARUNVIPAS, Chokchai SANGDAO, Ravee PHROMLOUNGSRI
Article type: PAPER
Subject area: Microwaves, Millimeter-Waves
2011 Volume E94.C Issue 9 Pages
1447-1454
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
This paper presents novel structures of band-pass filters using two configurations of open loop ring resonators (OPLRR): a resonator with embedded quadruply-stepped impedance transmission lines (QSITL) in coupled lines, and a stepped impedance resonator (SIR). Both types of OPLRR have the capability of suppressing the second spurious response and shifting the third spurious response to a higher frequency as well. To demonstrate the performances of both proposed resonators, two sections of each structure with cascaded and crossed configurations at an operating frequency of 0.9GHz are presented. Both methodologies are easy to design and implement. The methodology with a SIR has a better performance than the SITL. The measurement results of the proposed circuits are in full agreement with the simulated prediction results.
View full abstract
-
Huey Chian FOONG, Meng Tong TAN, Yuanjin ZHENG
Article type: PAPER
Subject area: Electronic Circuits
2011 Volume E94.C Issue 9 Pages
1455-1463
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
This paper presents the design and implementation of a supply and process-insensitive 12-bit Digital Pulse Width Modulator (DPWM) for digital DC-DC converters. The DPWM is realized by a ring oscillator-based segmented tapped delay line and a counter-comparator. The number of delay cells required is reduced by employing a proposed delay cell reuse technique. The ring oscillator of the tapped delay line is made insensitive to supply and process variation by biasing the differential delay cells with a supply-insensitive replica bias circuit. Simulation results show that the variation of the switching frequency of the DPWM at 1.02MHz is 0.4% for supply voltage variation between 1.5V and 2.5V and 0.95% over the temperature range from -40°C to 90°C. Monte-Carlo simulation was also performed to account for the effect of mismatch between the transistors of the ring oscillator. The worst case delay of the delay cells is 0.87% for ±5% (3-σ) mismatch. The design was fabricated in CMOS 0.18µm process and the fabricated DPWM achieved a supply sensitivity of 0.82% and a current consumption of 14µA.
View full abstract
-
Chun-Hsun WU, Le-Ren CHANG-CHIEN
Article type: PAPER
Subject area: Electronic Circuits
2011 Volume E94.C Issue 9 Pages
1464-1471
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
Low drop-out regulators (LDOs) are widely used in the system-on-a-chip (SoC) design. Due to the multi-function and energy saving requirements for mobile applications nowadays, more strict specifications are expected on the developmental roadmap of the LDOs. An output-capacitorless LDO providing fast transient response under the low supply voltage and low quiescent current conditions is proposed in this paper. Provided by the low supply voltage, the proposed LDO adopts cascading technique using the Multipath Nested Miller Compensation (MNMC) to maintain a higher bandwidth for fast transient requirement. In addition, a Transient Quiescent Current Booster (TQCB) is supplemented to the operational amplifier to improve the slew rate for the fast load transient. The TQCB only raises the quiescent current during the load transient instant so that both power saving and the load response improvement could be well achieved. It deserves noting that the proposed TQCB contains only two transistors, which is simple to be implemented compared to the other transient current enhancement techniques. The designed LDO has only 1.6pF capacitance for the totally added on-chip compensation, and 25.8µA of current consumption in the main amplifier. The recovery time under the fast load change is less than 3µs and the stability is guaranteed. Test results from the real implementation of a 0.35µm CMOS process verify that the designed LDO performs as expected.
View full abstract
-
Yupin SUPPAKHUN, Pornchai SUPNITHI, Yoshihiro OKAMOTO, Yasuaki NAKAMUR ...
Article type: PAPER
Subject area: Storage Technology
2011 Volume E94.C Issue 9 Pages
1472-1478
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In this paper, we propose a new method to estimate and effectively reduce the effect of thermal asperity (TA) in the perpendicular magnetic recording (PMR) channels with the state trellis. The TA is estimated from the state trellis, then its average is used to modify the equalized signal entering the Viterbi detector. For the partial response (PR) targets with DC component, the proposed method with a maximum-likelihood detector can improve the bit error rate performance by more than an order of magnitude when TA occurs and degrades when the giant magneto-resistive (GMR) nonlinearity and base line wander (BLW) effects are present. Unlike the previous studies, this method allows the use of PR targets with DC component under the presence of TA.
View full abstract
-
Haiyan JIN, Xianzhi DU, Fulin XIAO, Guangjun WEN
Article type: BRIEF PAPER
Subject area: Microwaves, Millimeter-Waves
2011 Volume E94.C Issue 9 Pages
1479-1482
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In this paper, we propose a wideband four-way turnstile-junction waveguide divider/combiner in the Ka-band. The proposed divider/combiner has an insertion loss of less than 0.8dB over the frequency range of 28-39.5GHz. A power combiner amplifier using this circuit and four MMIC amplifiers has been demonstrated with 83% combining efficiency at 34.9GHz. The measured results show that the turnstile-junction waveguide divider-combiner is a suitable element for developing a broadband millimeter-wave spatial power combiner amplifier.
View full abstract
-
Joon-Yub KIM, Yeon Tae JEONG, Byung-Gwon CHO
Article type: BRIEF PAPER
Subject area: Electronic Displays
2011 Volume E94.C Issue 9 Pages
1483-1485
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
The address discharge characteristics formed when an address pulse is applied in AC plasma display panels are investigated by changing the ramp-down voltage during the reset period. The address discharge time lag can be reduced when the difference between the ramp-down voltage and the scan-low voltage is set at a high value during the ramp-down period because the loss of the wall charges accumulated between the scan (Y) and address (A) electrodes during the reset period is minimized. In addition, the voltage applied to the X electrode during the ramp-down period can prevent the voltage margin from reduction even though applying high voltage difference on the Y electrodes.
View full abstract
-
Weiwei SHAN, Xin CHEN
Article type: BRIEF PAPER
Subject area: Electronic Instrumentation and Control
2011 Volume E94.C Issue 9 Pages
1486-1489
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In this brief paper, both static and dynamic behaviors of an electrostatic-actuated MEMS mirror are modeled and studied. To overcome the intrinsic pull-in problem and the dynamic disadvantages in the open-loop controlled actuation, a novel closed-loop feedback control method is proposed assuming the mirror tilt angle can be measured. First, a fixed voltage slightly higher than the pull-in voltage is applied when the mirror tilt angle is small. Then Proportional-Derivative (PD) control is used when the mirror is approaching the target position. Simulink simulation results show that this combined PD closed-loop control can overcome the pull-in problem and improve the dynamic behavior; furthermore, it can also enhance the robustness of the mirror actuation system to overcome environmental disturbances.
View full abstract
-
Dong-Su LEE, Sung-Chan KANG, Young-Hyun JUN, Bai-Sun KONG
Article type: LETTER
Subject area: Electronic Circuits
2011 Volume E94.C Issue 9 Pages
1490-1493
Published: September 01, 2011
Released on J-STAGE: September 01, 2011
JOURNAL
RESTRICTED ACCESS
In this letter, a novel body bias selection scheme for minimizing the leakage of MOS transistors is presented. The proposed scheme directly monitors leakages at present and adjacent body bias voltages, and dynamically updates the voltage at which the leakage is minimized regardless of process and temperature variations. Comparison results in a 46nm CMOS technology indicated that the proposed scheme achieved leakage reductions of up to 68% as compared to conventional body biasing schemes.
View full abstract