In this paper, emission intensity tables of greenhouse gas (especially HFC, PFC and SF
6) are presented and LCA (Life Cycle Assessment) case studies using those tables are discussed.
The emission intensity tables of greenhouse gas are derived from Economic Input-Output Tables (I/O tables) and several statistical data. The emission intensities derived from the total amount transferred between sections in I/O tables become larger than the intensities derived from the actual amount of gases transferred between sections. In order to calculate the intensities of these gases, certain sections of the I/O tables should be decomposed. The I/O tables are modified, adding these sections, which correspond to ″HFC″, ″PFC″, ″HCFC″ and ″SF
6″ manufacturing industries. The emission intensities become large in not only ″HFC″, ″PFC″, ″HCFC″, ″SF
6″ subsections, but also ″Semiconductor devices and integrated circuits″, ″Liquid crystal devices″ and ″Relay switches and switchboards″ sections.
LCA case studies are conducted on a laptop PC and an air conditioner. The greenhouse gas emission at each stage of the life cycle is increased by about 20% for a laptop PC and by about 1% for an air conditioner with the CO
2 equivalent compared with the result calculated by the emission intensity tables of CO
2 and N
2O.
抄録全体を表示