Journal of Structural and Construction Engineering (Transactions of AIJ)
Online ISSN : 1881-8153
Print ISSN : 1340-4202
ISSN-L : 1340-4202
BOND STRESS-SLIP CHARACTERISTICS OF REINFORCING BARS IN GROUT-FILLED COUPLING STEEL SLEEVES
Yoshihisa HAYASHIRyohei SHIMIZUTadashi NAKATSUKAKazuo SUZUKI
Author information
JOURNAL FREE ACCESS

1994 Volume 59 Issue 462 Pages 131-139

Details
Abstract
Effects of variables, such as development length of reinforcing bars, kinds and compressive strength of grout, etc., on bond stress-slip relations of reinforcing bars in splices having grout-filled coupling sleeves of electric resistance welded steel tubes. Following main conclusions are obtained. (1) In pre-yield regions of reinforcing bars in splices with the same grout, the bond stress-slip relations which are considered to be almost similar are obtained. (2) Assumption of different constant bond stress in both pre- and post-yield regions of reinforcing bars in the splices leads equations to estimate practically both load capacities and failure modes of the splices.
Content from these authors
© 1994 Architectural Institute of Japan
Previous article Next article
feedback