Analytical Sciences
Online ISSN : 1348-2246
Print ISSN : 0910-6340
ISSN-L : 0910-6340
Notes
Time-resolved Measurement of Copper Emission Spectrum Excited by a Low-pressure Argon Laser-induced Plasma
Yohei USHIROZAWAKazuaki WAGATSUMA
Author information
JOURNAL FREE ACCESS

2006 Volume 22 Issue 7 Pages 1011-1015

Details
Abstract

A laser-induced plasma generated with a pulsed Nd:YAG laser under evacuated conditions has complicated structures both temporally and spatially. The time-resolved spectra of copper in three different wavelength regions were observed in detail for elucidating the excitation mechanisms of many atomic/ionic copper emission lines. The emission intensities of copper emission lines, measured in a time-resolved mode, were strongly dependent on the kind of copper lines: ionic or atomic lines, and their excitation energies. Generally, copper ionic lines were rapidly decayed and dominantly emitted from the initial breakdown zone, because the copper ions requiring larger excitation energies were produced mainly in the hot breakdown zone. On the other hand, the atomic lines were emitted during prolonged periods, implying that they could also be excited in the expanded plasma zone. The excitation phenomena occurring in the laser-induced plasma could be better understood by analyzing the time-resolved copper spectra.

Content from these authors
© 2006 by The Japan Society for Analytical Chemistry
Previous article Next article
feedback
Top