Industrial Health
Online ISSN : 1880-8026
Print ISSN : 0019-8366
ISSN-L : 0019-8366
Original Articles
Chemical Exposures in Research Laboratories in a University
Shiro TAKADASatoru OKAMOTOChikahisa YAMADAHirohiko UKAIHajime SAMOTOFumiko OHASHIMasayuki IKEDA
Author information
JOURNAL FREE ACCESS

2008 Volume 46 Issue 2 Pages 166-173

Details
Abstract

Research laboratories in a university were investigated for air-borne levels of legally designated organic solvents and specified chemical substances. Repeated surveys in 2004-5 (four times in the two years) of about 720 laboratories (thus 2,874 laboratories in total) revealed that the solvent concentrations were in excess of the Administrative Control Levels only in a few laboratories (the conditions improved shortly after the identification) and none with regard to specified chemicals. Thus, working environments were in Control Class 1 in almost all (99.5%) laboratories examined. Such conditions were achieved primarily by extensive installation and use of local exhaust systems. The survey further revealed that types of chemicals used in research laboratories were extremely various (only poorly covered by the regulation) whereas the amounts of each chemical to be consumed were quite limited. For protection of health of researchers (including post- and under-graduate students) in laboratories, therefore, it appeared more appropriate to make personal exposure assessment rather than evaluation of levels of chemicals in air of research laboratories. Considering unique characteristics of research activity, it is important to educate each researcher to make his/her own efforts to protect his/her health, through supply of knowledge on toxicity of chemicals as well as that on proper use of protective equipments including exhaust chambers.

Content from these authors
© 2008 by National Institute of Occupational Safety and Health
Previous article Next article
feedback
Top