2012 Volume 52 Issue 2 Pages 174-180
Round-robin tests were conducted for designing standard procedures for thermal desorption analysis (TDA) of hydrogen. Scatters of diffusive and non-diffusive hydrogen contents measured at various institutions using common materials and experimental procedures were examined. Some factors causing the scatter and their respective contributions were examined in optional tests.