Original Article
Comparison of shear bond strength of reattached incisor fragment using Er,Cr:YSGG laser etching and conventional acid etching: An in vitro study
Ferah RehmanGyanendra KumarMridula GoswamiJatinder Kaur Dhillon
Author information
JOURNAL FREE ACCESS

2016 Volume 25 Issue 2 Pages 115-120

Details
Abstract

Aim: The aim of this in vitro study is to evaluate the shear bond strength of reattached fractured incisor fragments using Er,Cr:YSGG laser and conventional acid etching without additional tooth preparation.
Material and methods: Forty extracted human teeth were divided in two groups of 20 each (Groups A and B). In Group A, fractured surface was treated by an Er, Cr: YSGG laser system (Waterlase MD, Biolase Technology Inc., San Clemente, CA, USA) operating at a wavelength of 2,780 nm and frequency of 20 Hz. In Group B, fractured surface was etched using 37% phosphoric acid (Scotchbond, 3M). In both the groups, further subdivision with 10 sample each was made based on horizontal and oblique fracture. After laser or acid etching, all the samples were reattached using flowable composite resin and light cured. The samples were tested for shear bond strength.
Results: Mean shear bond strength for Group A (94.70±39.158) was lower as compared to Group B (121.25±49.937), although the difference was not statistically significant(p value=0.121). Similarly no statistical significant difference was observed amongst the subgroups. (p>0.05)
Conclusions: Er,Cr:YSGG laser etching in reattachment of fractured incisor fragment is a good alternative to conventional acid etching. Er,Cr:YSGG showed comparable efficiency in rebonding of fractured teeth fragment as acid etching.