Surgery for Cerebral Stroke
Online ISSN : 1880-4683
Print ISSN : 0914-5508
ISSN-L : 0914-5508
Topics: New Attempt for Bypass Surgery
Practical Application of 3-D Multifusion Imaging for STA-MCA “Tailored” Bypass
Yujiro TANAKAIchiro NAKAHARATsuyoshi OHTARyota ISHIBASHIMasanori GOMIHaruka MIYATASadayoshi WATANABE
Author information
JOURNAL FREE ACCESS

2014 Volume 42 Issue 6 Pages 432-438

Details
Abstract

Background: The indication of extracranial-intracranial (EC-IC) bypass surgery is likely to be limited, because the prognosis for ischemic stroke improves with better outcomes with medical therapy. Therefore, to achieve the maximum benefit in selected cases, an individualized surgical plan tailored to anatomical differences and the purpose of the surgery is necessary. We describe our practical application of 3-D multifusion imaging for “tailored” bypass surgery.
Methods: We selected the ideal recipient artery and simulated the craniotomy preoperatively using 3-D multifusion imaging on a general purpose workstation in 13 cases of EC-IC bypass treated in Kokura Memorial Hospital between October 2011 and October 2012. We identified discrepancies between imaging and the actual intra-operative view, and modified the image editing and operative procedure.
Results: In all 13 cases, bypass flow was maintained. There were positional deviations between the simulated craniotomy and the intra-operative view in two cases initially. In another two cases, we could not select the recipient artery because of insufficient visualization of the brain surface. Both problems were correctable.
Conclusion: We accurately identified the recipient artery that we had selected pre-operatively. This technique can be a stepping stone to “tailored bypass” and could be applied to various cerebrovascular surgeries.

Content from these authors
© 2014 by The Japanese Society on Surgery for Cerebral Stroke
Previous article Next article
feedback
Top