Applied Human Science
Print ISSN : 1341-3473
ORIGINALS
Distribution of Muscle Fiber Conduction Velocity of M. Biceps Brachii During Voluntary Isometric Contraction with Use of Surface Array Electrodes
Weiqiang LiKazuyoshi Sakamoto
Author information
JOURNAL FREE ACCESS

1996 Volume 15 Issue 1 Pages 41-53

Details
Abstract

Surface electromyogram (EMG) was recorded in m. biceps brachii during the contractions of 20, 40 and 60% of maximum voluntary isometric contraction (MVC) in twelve healthy male subjects, using surface array electrodes. The distribution of muscle fiber conduction velocity (MFCV) was found directly using the averaging technique and the cross-correlation function technique. MFCVs in the region of 20-45 mm measured from end-plate denoted constant value of about 4 m/s in 20% MVC, while MFCVs in the region around end-plate and tendons showed about 10 m/s in 20% MVC. The values of MFCV depended on the contraction levels of muscle. The model for the generation of MFCV which considered the ensemble of muscle fibers with the shape of a cone was proposed. The theoretical values of MFCV by the muscle fiber ensemble model (MFE model) proposed in the paper showed in good agreement with the experimental results.

Content from these authors
© 1996 Japan Society of Physiological Anthropology
Previous article
feedback
Top