Annals of Japan Prosthodontic Society
Online ISSN : 1883-6860
Print ISSN : 1883-4426
ISSN-L : 1883-4426
Case Reports (Specialist)
A case treated by modifying the design of the major connector to reduce the discomfort of a removable partial denture
Hidetoshi Otsuka
Author information
JOURNAL FREE ACCESS

2023 Volume 15 Issue 3 Pages 377-380

Details
Abstract

Patient: A 66-year-old female patient presented at our hospital with a chief complaint of difficulty with mastication and compromised esthetics as a consequence of not using her mandibular removable partial denture. The patient’s masticatory function was improved by modifying the design of the major connector of the removable partial denture. A fixed partial denture was also fabricated to treat the compromised maxillary esthetics.

Discussion: The findings of this case report showed that the modified design of the major connector minimized interference of the removable partial denture with the tongue and improved the support and bracing provided by the denture, thus reducing discomfort during use.

Conclusion: It was concluded that the modified design of the major connector in a removable partial denture was associated with decreased discomfort.

Content from these authors
© 2023 Japan Prosthodontic Society
Previous article Next article
feedback
Top