Asian Pacific Journal of Dentistry
Online ISSN : 2185-3487
Print ISSN : 2185-3479
Original article
Bonding performance of self-adhesive luting agents to highly translucent zirconia ceramics
Toyoaki KobayashiTomohiro TakagakiRena Takahashi Masaomi IkedaJunji Tagami
Author information
JOURNAL FREE ACCESS FULL-TEXT HTML

2020 Volume 20 Issue 2 Pages 29-33

Details
Abstract

Purpose: The purpose of this study was to evaluate the long-term durability of the bonds between self-adhesive luting agents and yttria-stabilized partially stabilized zirconia (Y-PSZ) and the effect of phosphoric acid etching as a surface pre-treatment to Y-PSZ.

Materials and Methods: A total of 180 Y-PSZ disks were divided into two groups; the control group and the phosphoric acid etching group prior to the bonding with one of three self-adhesive luting agents; Panavia SA Cement Plus Automix (SAP), RelyX Unicem2 Automix (UC2), or Maxcem Elite Chroma (MXE). Bonded specimens were stored in distilled water, for 1 day, 30 days, or 150 days. After storage, the tensile bond strength was measured using a universal testing machine. The data were statistically analyzed using Welch's t-test and Welch's t-test with Bonferroni correction (α = 0.05).

Results: The tensile bond strength of each luting agent measured more than 15 MPa after 1 day of immersion in distilled water with or without phosphoric acid etching. There were no significant differences between SAP and UC2 after 30 days and 150 days (p > 0.05) of immersion. SAP and UC2 showed significantly higher bond strength than MXE after 30 days and 150 days (p < 0.05) of immersion. There were no significant differences between with/without phosphoric acid etching in all groups (p > 0.05).

Conclusion: Durability of self-adhesive luting agent to Y-PSZ was material-dependent. A surface pre-treatment with phosphoric acid etching to Y-PSZ did not affect the bond strength of self-adhesive luting agent to Y-PSZ.

Introduction

Ceramic dental restorations have become increasingly popular due to their good esthetics and biocompatibility as compared with porcelain-fused-to-metal (PFM) restorations [1]. Early generation zirconia, conventional yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), have outstanding mechanical properties but exhibit an inherent opacity that makes its use less desirable when the esthetic appeal is essential [2]. Recently, yttria-stabilized partially stabilized zirconia (Y-PSZ) has been introduced in dentistry. Y-PSZ contains more Y2O3-stabiliser than Y-TZP and this results in a significant amount of cubic zirconia phase [3], which makes Y-PSZ highly translucent and especially suitable for anterior esthetic crowns [2]. Y-PSZ is more hydrothermally stable but has lower levels of mechanical properties than Y-TZP [3].

In comparison with silica-based ceramics, zirconia-based ceramics present difficulty in forming reliable and durable bonds with luting agents [4]. Correct luting agent selection is a prerequisite for obtaining good bonding and success of indirect restorations. Luting agents are recommended for adhesive bonding in dentistry because of their low solubility in the oral environment, reduced microleakage at the restoration-tooth interface, and good optical properties [5]. Self-adhesive luting agents represent the latest and most simplified category of luting agents that is much easier to use than the rest. Therefore, these luting agents have rapidly gained popularity as luting agents for all types of ceramic restorations.

Before the seating procedure, phosphoric acid gel is widely used in clinical situations to remove contaminants from the inner surface of restorations. At present, little information is available regarding phosphoric acid etching as a surface pre-treatment to Y-PSZ for its use in conjunction with self-adhesive luting agent. Therefore, the purpose of this study was to evaluate the long-term durability of the bond between self-adhesive luting agents and Y-PSZ and the effect of phosphoric acid etching as a surface pre-treatment to Y-PSZ. The null hypotheses tested in this study were that (i) selection of self-adhesive luting agent does not affect the bond strength between self-adhesive luting agent and Y-PSZ, (ii) the length of the storage period does not affect the bond strength between self-adhesive luting agent and Y-PSZ, and (iii) a surface pre-treatment with phosphoric acid etching to Y-PSZ does not affect the bond strength of self-adhesive luting agent to Y-PSZ.

Materials and Methods

The materials used in this study are listed in Table 1. One hundred and eighty fully sintered Y-PSZ disk-shaped specimens (Katana HT, Kuraray Noritake Dental, Tokyo, Japan) of 5 mm thickness 12 mm diameter were randomly divided into 18 groups (n = 10). All specimens were finished with 600-grit silicon carbide paper under running water and air-abraded using a blasting machine (Basic eco, Renfert, Hilzingen, Germany) with 0.3 MPa using 50 m alumina particles (Cobra, Renfert) for 20 s from a distance of 10 mm. Then they were ultrasonically cleaned in deionized water for 5 min and 99% ethanol for 2 min. The cleaned specimens were divided into two groups: the control (PA–) group and the phosphoric acid (PA+) group. The specimens in the PA+ group were treated with 40% phosphoric acid (K-etchant Gel, Kuraray Noritake Dental) for 20 s with a rubbing motion, left to stand for 10 s, rinsed with water for 20 s, and air-dried for 10 s. After the pretreatment, a plastic tape with a circular hole (4 mm in diameter and 100 m in thickness) was placed on each of the specimens to demarcate the area for bonding.

Table 1 Materials used

Material Code Manufacturer Compositions Batch No.
Katana
Zirconia HT
Zirconia Kuraray Noritake Dental,
Tokyo, Japan
ZrO2, 90-95%; Y2O3, 5-8%; Others, <2%

not available
Panavia SA Cement Plus Automix SAP Kuraray Noritake Dental bis-GMA, TEGDMA, HEMA, 10-MDP, hydrophobic aromatic dimethacrylate, hydrophobic aliphatic dimethacrylate, sodium fluoride, silanated barium glass filler, silanated colloidal silica (70 wt% / 40 vol%)
4E0205
RelyX Unicem2 Automix UC2 3M ESPE,
St. Paul, MN, USA
Base Paste: methacrylate monomers containing phosphoric acid groups, methacrylate monomers, silanated fillers (70 wt% / 43 vol%), initiator components, stabilizers, rheological additives
Catalyst Paste: methacrylate monomers, alkaline (basic) fillers, initiator components, stabilizers, pigments, rheological additives
670650
Maxcem Elite Chroma MXE Kerr Corporation,
Orange, CA, USA
HEMA, GDM, UDMA, 1,1,3,3-tetramethylbutyl hydroperoxide TEGDMA, fluoroaluminosilicate glass, GPDM, barium glass filler, fumed silica (69 wt%)
6325871
K-etchant Gel PA Kuraray Noritake Dental 40% phosphoric acid, water, colloidal silica, dye

CG0055
Alloy Primer metal primer Kuraray Noritake Dental VBATDT, 10-MDP, acetone
A40088

bis-GMA, bisphenol-A-diglycidylmethacrylate; TEGDMA, triethyleneglycol dimethacrylate; HEMA, 2-hydroxyethyl methacrylate; 10-MDP: 10-methacryloyloxydecyl dihydrogen phosphate; GDM, 1,3-glycerol dimethacrylate; UDMA, urethane-dimethacrylate; GPDM, glycero-phosphate dimethacrylate; VBATDT, 6-(4-vinylbenzyl-n-propyl)amino-1,3,5-triazine-2,4-dithione

Stainless steel rods (8 mm diameter and 30 mm length) were used as an adherend. Stainless steel rods were finished with 600-grit silicon carbide papers and air-abraded in the same manner as Y-PSZ specimens. Then they were ultrasonically cleaned with water for 3 min. Stainless-steel rods were treated with metal primer (Alloy Primer, Kuraray Noritake Dental), and bonded to the Y-PSZ specimens with one of the three automix self-adhesive luting agents, Panavia SA Cement Plus Automix (SAP, Kuraray Noritake Dental), RelyX Unicem2 Automix (UC2, 3M ESPE, St. Paul, MN, USA), or Maxcem Elite Chroma (MXE, Kerr Corporation, Orange, CA, USA). Excess luting agent was removed from the bonding margin with a micro-brush and light-cured with an LED light-curing unit (VALO, Ultradent, South Jordan, UT, USA) at standard mode (1,000 mW/cm2) from each quarter for 10 s, that is, for 40 s in total. The bonded specimens were left at room temperature for 30 min. Then they were stored in deionized water at 37˚C for 1 day, 30 days, or 150 days. The tensile bond strengths (TBS) were measured using a universal testing machine (Autograph AGS-J, Shimadzu, Kyoto, Japan) at a crosshead speed of 2 mm/min. Bond strength data were statistically analyzed in SPSS software (SPSS 22, IBM; Armonk, NY, USA) at a significance level of α = 0.05. Data distribution was evaluated primarily with the Shapiro-Wilk test, and equality of variance was evaluated with the Levene’s test. When the Shapiro-Wilk test showed a normal distribution and the Levene’s test did not show homogeneity of variances, then the data were analyzed with Welch's t-test to evaluate the differences between PA– and PA+, and Welch's t-test with Bonferroni correction to evaluate the differences among the luting agents and to evaluate the differences among the periods of storage.

After debonding, fractured specimens were observed with an optical microscope (SMZ100, Nikon, Tokyo, Japan) at 8 magnification. The fractured specimens were classified into the following two types: A, adhesive failure at the interface between Y-PSZ and luting agent; and B, cohesive failure in luting agent and mixed failure.

Results

The TBS test results are shown in Table 2. Within the same luting agent and the same PA condition, there were significant differences among 1 day and 30 days, and 1 day and 150 days storage periods in all groups (p < 0.05). However, the differences between 30 days and 150 days periods were not significant in any of the groups (p > 0.05). Within the same period and the same PA conditions, there were no significant differences between UC2 and MXE after 1 day, and between SAP and UC2 after 30 days and 150 days of storage (p > 0.05). There were no significant differences between PA– and PA+ in all groups (p > 0.05).

Representative fracture mode images are shown in Fig. 1. In the SAP groups, only type B was observed regardless of the PA status and storage period. In the UC2 groups, both type A and type B were observed regardless of their PA status and storage period. In the MXE groups, both type A and type B were observed regardless of their PA status after 1 day. Only type A was observed regardless of its PA status after 30 days and 150 days.

Fig. 1 Representative fracture mode images

A, adhesive failure at the interface between Y-PSZ and luting agent; B, cohesive failure in luting agent and mixed failure

Table 2 Tensile bond strength in MPa and the fracture mode distribution (Type A / Type B)

Luting agent PA 1 day 30 days 150 days
SAP 21.60 ± 4.65 (0/10) 8.64 ± 1.41aC (0/10) 9.20 ± 3.20aE (0/10)
+ 18.30 ± 6.04A (0/10) 10.03 ± 3.34bD (0/10) 9.90 ± 2.08bF (0/10)
UC2 15.13 ± 4.72B (4/6) 8.12 ± 2.33cC (2/8) 9.72 ± 3.21cE (2/8)
+ 17.45 ± 5.04A (2/8) 6.73 ± 1.69dD (5/5) 7.05 ± 2.47dF (3/7)
MXE 18.54 ± 11.56B (4/6) 0.32 ± 0.01e (10/0) 0.37 ± 0.02e (10/0)
+ 17.70 ± 10.78A (2/8) 0.34 ± 0.02f (10/0) 0.32 ± 0.02f (10/0)

All values are the mean ± SD.

When the PA condition and the period are same, the values with the same capital superscript letters indicate no significant differences among the luting agents (p > 0.05).

Same small superscript letters indicate no significant differences within the row (p > 0.05).

Type A, adhesive failure at the interface between Y-PSZ and luting agent

Type B, cohesive failure in luting agent and mixed failure

Discussion

The acidic functional monomers play a key role in self-adhesive luting agents. Molecular structure of functional monomers strongly influences the chemical interaction and bonding performance of luting agents with zirconia ceramics [6]. Each of the self-adhesive luting agents used in the present study contains specific acidic phosphate monomers.

SAP contains 10-methacryloyloxydecyl dihydrogen phosphate (MDP), a phosphate methacrylate adhesive monomer, which has originally developed to bond to tooth structure and metal oxide restorative material. Research have shown that MDP promotes adhesion to zirconia through the chemical interaction between the phosphate ester group of MDP and the hydroxyl groups in the zirconia surface [7,8,9]. The chemical bond between MDP and bisphenol-A-diglycidyl-methacrylate (bis-GMA) composite resins is established by the methacrylate group of MDP and the composite resin matrix of the luting agent. The MDP molecule increases the bond strength by converting a hydrophilic surface to a hydrophobic one and by forming phosphoric acid salts between the composite and zirconia [10]. Additionally, the MDP molecule forms a hydrogen bond between of MDP and zirconia [10,11]. The combination of airborne particle abrasion and MDP monomer contained either in the adhesive primer or in the luting agent itself is the recommended method of bonding to zirconia [12,13,14,15]. In PA- group, SAP showed higher bond strength than UC2 and MXE after 1 day of storage in the present study. After 30 days and 150 days of storage, the SAP groups showed lower bond strength than after 1 day. However, all specimens of SAP group did not show adhesive failure at the interface between zirconia and luting agent. This result was in line with the previous study [16]. Accumulation of MDP on the zirconia surface probably improved adhesion and degree of conversion of luting agent [6].

UC2 has the characteristic of self-etching phosphorylated methacrylate that is designed to bond directly to both enamel and dentin. With two phosphate groups and at least two double-bonded carbon atoms, good bond strength with zirconia and adequate cross-linking to the resin matrix are achieved [17]. Self-adhesive luting agents have a low pH, and the acidic groups join with calcium hydroxyapatite to form a stable bond between the methacrylate network and tooth [18]. UC2 has been reported to have stable physical properties, i.e., water sorption, solubility, flexural strength, and pH-neutralization behavior [19]. Therefore, UC2 showed comparable TBS to SAP after 30 days and 150 days regardless of PA.

Although MXE group showed more than 15 MPa after 1 day of storage, the bond strength TBS of MXE dropped dramatically after 30 days and 150 days of storage. MXE contains glycerol-phosphate dimethacrylate (GPDM) which is one of the first chemical compounds proposed to bond to human dentin [20]. GPDM has one phosphate acidic functional group and two polymerizable methacryloyl groups [6,21]. A previous study reported that chemical interactions of GPDM with zirconia ceramic surfaces do not exhibit ordered arrangement due to steric hindrance [6].

GDM and tetramethylbutyl hydroperoxide in MXE may be responsible for water uptake and stress build-up associated with hydroscopic expansion. GDM has relatively higher hydrophilicity and water sorption [22] than other methacrylate monomers contained in SAP and UC2. Consequently, MXE was more prone to hydrolytic degradation. Thus, after 30 days and 150 days of storage MXE groups showed extremely low bond strength and a high rate of adhesive failure at the interface between zirconia and luting agent.

Differences in chemical and physical properties of self-adhesive luting agents may affect the bonding mechanism and bonding durability to zirconia ceramic [23,24]. According to what is stated above, the first and second null hypotheses were rejected, which means the selection of self-adhesive luting agent and storage period affected the bond strength of self-adhesive luting agent to Y-PSZ.

In the present study, a surface pre-treatment with phosphoric acid etching to Y-PSZ did not affect the bond strength in all groups. Thus, the third null hypothesis was accepted. In a clinical situation, contamination of the inner surface of restorations by saliva, blood, or silicone indicators during the try-in procedure of restoration is unavoidable [25]. Contamination deteriorates the bonding of the restoration, but this problem could be solved by using various surface cleaning methods. As for the mechanical cleaning method, alumina blasting is one of the effective methods to clean saliva contaminated restorations [26,27,28]. Airborne-particle abrasion cleans the bonding surface and increases roughness, surface area, and surface energy and therefore the wettability of zirconia surfaces [29,30]. Moreover, airborne-particle abrasion may generate on the zirconia surfaces the hydroxyl groups that facilitate the chemical reaction with phosphate monomer containing self-adhesive luting agent [30,31]. As for chemical cleaning methods, the use of a product composed of a hypersaturated solution of zirconia particles in sodium hydroxide was recommended [32,33].

Several studies revealed that although PA removes organic residues from salivary contamination [26], PA might change the surface energy at the zirconia surface and, thereby, reduce the bonding properties [26,27,34,35]. Applying PA to surfaces of zirconia leaves a phosphorous residue that impairs the bond strength to luting agent [26,28,36]. The reason for the inconsistency of results between the previous studies and the present study was not clear, surface pretreatment with phosphoric acid etching did not improve the bond strength of any self-adhesive luting agents.

Within the limitation of this study, it can be concluded that the durability of self-adhesive luting agent to Y-PSZ was material-dependent. Also, a surface pre-treatment with phosphoric acid etching to Y-PSZ did not affect the bond strength of self-adhesive luting agent to Y-PSZ.

Acknowledgments

The authors gratefully thank Kuraray Noritake Dental Inc. for the supporting materials used in this study.

Conflicts of Interest

None of the authors have any conflict of interest to declare.

References
  • 1. Ozer F, Mante FK, Chiche G, Saleh N, Takeichi T, Blatz MB. A retrospective survey on long-term survival of posterior zirconia and porcelain-fused-to-metal crowns in private practice. Quintessence Int 2014; 45: 31-8.
  • 2. Stawarczyk B, Keul C, Eichberger M, Figge D, Edelhoff D, Lümkemann N. Three generations of zirconia: From veneered to monolithic. Part I. Quintessence Int 2017; 48: 369-80.
  • 3. Inokoshi M, Shimizu H, Nozaki K, Takagaki T, Yoshihara K, Nagaoka N, et al. Crystallographic and morphological analysis of sandblasted highly translucent dental zirconia. Dent Mater 2018; 34: 508-18.
  • 4. Zarone F, Russo S, Sorrentino R. From porcelain-fused-to-metal to zirconia: clinical and experimental considerations. Dent Mater 2011; 27: 83-96.
  • 5. Hill EE, Lott J. A clinically focused discussion of luting materials. Aust Dent J 2011; 56 Suppl 1: 67-76.
  • 6. Arai M, Takagaki T, Takahashi A, Tagami J. The role of functional phosphoric acid ester monomers in the surface treatment of yttria-stabilized tetragonal zirconia polycrystals. Dent Mater J 2017; 36: 190-4.
  • 7. Ozcan M, Nijhuis H, Valandro LF. Effect of various surface conditioning methods on the adhesion of dual-cure resin cement with MDP functional monomer to zirconia after thermal aging. Dent Mater J 2008; 27: 99-104.
  • 8. Papia E, Larsson C, du Toit M, Vult von Steyern P. Bonding between oxide ceramics and adhesive cement systems: a systematic review. J Biomed Mater Res B Appl Biomater 2014; 102: 395-413.
  • 9. Tanış M, Akçaboy C. Effects of different surface treatment methods and MDP monomer on resin cementation of zirconia ceramics an in vitro study. J Lasers Med Sci 2015; 6: 174-81.
  • 10. Pilo R, Kaitsas V, Zinelis S, Eliades G. Interaction of zirconia primers with yttria-stabilized zirconia surfaces. Dent Mater 2016; 32: 353-62.
  • 11. Chen L, Suh BI, Brown D, Chen X. Bonding of primed zirconia ceramics: evidence of chemical bonding and improved bond strengths. Am J Dent 2012; 25: 103-8.
  • 12. Ozcan M, Kerkdijk S, Valandro LF. Comparison of resin cement adhesion to Y-TZP ceramic following manufacturers' instructions of the cements only. Clin Oral Investig 2008; 12: 279-82.
  • 13. Oyagüe RC, Monticelli F, Toledano M, Osorio E, Ferrari M, Osorio R. Effect of water aging on microtensile bond strength of dual-cured resin cements to pre-treated sintered zirconium-oxide ceramics. Dent Mater 2009; 25: 392-9.
  • 14. Lehmann F, Kern M. Durability of resin bonding to zirconia ceramic using different primers. J Adhes Dent 2009; 11: 479-83.
  • 15. Kern M, Barloi A, Yang B. Surface conditioning influences zirconia ceramic bonding. J Dent Res 2009; 88: 817-22.
  • 16. Aung SSMP, Takagaki T, Lyann SK, Ikeda M, Inokoshi M, Sadr A, et al. Effects of alumina-blasting pressure on the bonding to super/ultra-translucent zirconia. Dent Mater 2019; 35: 730-9.
  • 17. Mirmohammadi H, Aboushelib MN, Salameh Z, Feilzer AJ, Kleverlaan CJ. Innovations in bonding to zirconia based ceramics: Part III. Phosphate monomer resin cements. Dent Mater 2010; 26: 786-92.
  • 18. Burgess JO, Ghuman T, Cakir D. Self-adhesive resin cements. J Esthet Restor Dent 2010; 22: 412-9.
  • 19. Zorzin J, Petschelt A, Ebert J, Lohbauer U. pH neutralization and influence on mechanical strength in self-adhesive resin luting agents. Dent Mater 2012; 28: 672-9.
  • 20. Van Landuyt KL, Snauwaert J, De Munck J, Peumans M, Yoshida Y, Poitevin A, et al. Systematic review of the chemical composition of contemporary dental adhesives. Biomaterials 2007; 28: 3757-85.
  • 21. Yoshihara K, Nagaoka N, Hayakawa S, Okihara T, Yoshida Y, Van Meerbeek B. Chemical interaction of glycero-phosphate dimethacrylate (GPDM) with hydroxyapatite and dentin. Dent Mater 2018; 34: 1072-81.
  • 22. Park J, Eslick J, Ye Q, Misra A, Spencer P. The influence of chemical structure on the properties in methacrylate-based dentin adhesives. Dent Mater 2011; 27: 1086-93.
  • 23. Blatz MB, Phark JH, Ozer F, Mante FK, Saleh N, Bergler M, et al. In vitro comparative bond strength of contemporary self-adhesive resin cements to zirconium oxide ceramic with and without air-particle abrasion. Clin Oral Investig 2010; 14: 187-92.
  • 24. Pilo R, Papadogiannis D, Zinelis S, Eliades G. Setting characteristics and mechanical properties of self-adhesive resin luting agents. Dent Mater 2017; 33: 344-57.
  • 25. van Schalkwyk JH, Botha FS, van der Vyver PJ, de Wet FA, Botha SJ. Effect of biological contamination on dentine bond strength of adhesive resins. SADJ 2003; 58: 143-7.
  • 26. Yang B, Lange-Jansen HC, Scharnberg M, Wolfart S, Ludwig K, Adelung R, et al. Influence of saliva contamination on zirconia ceramic bonding. Dent Mater 2008; 24: 508-13.
  • 27. Ishii R, Tsujimoto A, Takamizawa T, Tsubota K, Suzuki T, Shimamura Y, et al. Influence of surface treatment of contaminated zirconia on surface free energy and resin cement bonding. Dent Mater J 2015; 34: 91-7.
  • 28. Yoshida K. Influence of cleaning methods on resin bonding to saliva-contaminated zirconia. J Esthet Restor Dent 2018; 30: 259-64.
  • 29. Kern M, Wegner SM. Bonding to zirconia ceramic: adhesion methods and their durability. Dent Mater 1998; 14: 64-71.
  • 30. Yang B, Barloi A, Kern M. Influence of air-abrasion on zirconia ceramic bonding using an adhesive composite resin. Dent Mater 2010; 26: 44-50.
  • 31. Sasse M, Kern M. Survival of anterior cantilevered all-ceramic resin-bonded fixed dental prostheses made from zirconia ceramic. J Dent 2014; 42: 660-3.
  • 32. Takahashi A, Takagaki T, Wada T, Uo M, Nikaido T, Tagami J. The effect of different cleaning agents on saliva contamination for bonding performance of zirconia ceramics. Dent Mater J 2018; 37: 734-9.
  • 33. Samran A, Al-Ammari A, El Bahra S, Halboub E, Wille S, Kern M. Bond strength durability of self-adhesive resin cements to zirconia ceramic: An in vitro study. J Prosthet Dent 2019; 121: 477-84.
  • 34. Yang B, Wolfart S, Scharnberg M, Ludwig K, Adelung R, Kern M. Influence of contamination on zirconia ceramic bonding. J Dent Res 2007; 86: 749-53.
  • 35. Angkasith P, Burgess JO, Bottino MC, Lawson NC. Cleaning methods for zirconia following salivary contamination. J Prosthodont 2016; 25: 375-9.
  • 36. Phark JH, Duarte S, Kahn H, Blatz MB, Sadan A. Influence of contamination and cleaning on bond strength to modified zirconia. Dent Mater 2009; 25: 1541-50.
 
© 2020 Asian Pacific Journal of Dentistry