Article ID: e26.48
Airborne ultrasound sensing requires both a suitable wavelength for the target and a short waveform duration for accurate echo discrimination. However, conventional airborne ultrasound emitters are narrowband owing to mechanical resonance, which results in elongated waveforms and reduced sensing accuracy. This study proposes a signal processing method for harmonic pulse compression based on bandwidth expansion using the Hilbert transform and frequency multiplication. The method is applied to nonlinear chirp signals generated by harmonic components in air under high-intensity ultrasound radiation. By multiplying the instantaneous phase of each extracted harmonic component, the sweep bandwidth can be expanded while preserving the waveform shape, enabling independent pulse compression without requiring prior knowledge of sound speed or wave arrival time. Experiments using an airborne ultrasound phased array demonstrated that harmonic components up to the fifth order could be processed individually, and the pulse width was reduced to approximately two periods of the sweep start frequency.