Application of Activated Clay for Improvement of Water Quality in Wire Electric Discharge Machining
Eri NagahashiFumihiko OgataTakehiro NakamuraNaohito Kawasaki
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML
Supplementary material

2019 Volume 2 Issue 6 Pages 119-124

Details
Abstract

In this study, the availability of activated clay treatment for decreasing the electrical conductivity in the real wire cut water was demonstrated. Activated clay (AC) was prepared, and its characteristics were investigated. The ability to adsorb Zn2+ and the removal ability through electrical conductivity were evaluated. It was found that the AC had a montmorillonite-like structure. Its specific surface area, micropore volume, mesopore volume, and macropore volume were 125.0 m2/g, 0.7 μL/g, 172.6 μL/g, and 13.7 μL/g, respectively. The cation exchange capacities at pH 5 and pH 10 were 56.2 and 67.2 cmol/kg, respectively. The effects of temperature, contact time, and pH of the solution on the adsorption of Zn2+ were measured. The amount of Zn2+ adsorbed by the AC increased with an increase in the adsorption temperature or in the pH. Adsorption isotherms data were fitted to the Freundlich equation compared to the Langmuir equation. Adsorption equilibrium was reached within 30 min, and kinetic data were fitted to the pseudo-second-order model compared to the pseudo-first-order model. Additionally, the AC was proven to effectively suppress the electrical conductivity. The suppression achieved by using washed AC was higher than that obtained by virgin AC. Washing AC with distilled water is useful for removing released ions (SO42-). Therefore, the column treatment packed with washed AC was evaluated in this paper. Finally, washed AC could remove Zn2+, resulting in the reduction of electrical conductivity (removal percentage is 47%). These findings provide significant information that can be useful for the removal of Zn2+ and reducing the electrical conductivity from wire cut water.

INTRODUCTION

Wire electric discharge machining is an innovative technology that can accurately and automatically cut even hard materials, such as carbides, into complicated shapes.1) Brass is mainly used as wire and is pulled through the workpiece from a supply spool onto the take-up equipment. During the application, an electric discharge occurs between the wire electrode and the work-piece in the presence of tap (or deionized) water with high resistivity.2) This phenomenon induces its capability of machining any material with electrical conductivity more than 0.01µS/cm (increasing the ion concentrations released from wire or workpiece).3)

In addition, it is important to achieve an optimal condition for the wire electric discharge machining. If the process is not performed in optimal conditions, serious problems such as short-circuiting of the wire, wire breakage, and work surface damage can easily occur.1) Therefore, many researchers suggested solutions that entail physicochemical techniques.1,37) One of them ensures the water quality by decreasing the amount of anions or cations in the tap water. In general, this is achieved by controlling the electrical conductivity through an ion exchange treatment. However, this technology is relatively costly and thus not economically feasible. Therefore, an alternative technique must be envisioned.

In this study, we focused on using an activated clay (AC) to decrease the electrical conductivity (i.e. the amount of ions) in aqueous solutions. Our AC is a 2:1 layered clay mineral, with a tetrahedral layer centered on silicon (or aluminum), and an octahedral layer centered on aluminum (or magnesium).8,9) Previous studies reported that AC is a much cheaper material; yet, it has a good adsorption capability which is beneficial for cation removal from aqueous solutions.10,11) However, no study reported on AC being applied for maintaining the water quality in wire electric discharge machining. Therefore, we used AC for the improvement of water quality in wire electric discharge machining.

In this study, we prepared the AC and investigated its physicochemical characteristics. The effect of temperature, contact time, and pH of the solution on the adsorption of ions by the AC were also evaluated. Finally, the application of the AC using a column was demonstrated. The obtained results provide new insights for improving water quality and thus the performance of wire electric discharge machining.

MATERIALS AND METHODS

Materials

A sample solution of zinc ions was prepared using zinc chloride (FUJIFILM Wako Pure Chemical Co., Japan). The AC was purchased from Kanto Chemical Co. Inc., Japan, and the “Washed AC” was prepared by the following method. Three grams of AC were added to 500 mL of purified water. The suspension was shaken at 100 rpm for 24 h at room temperature. Subsequently, the suspension was filtered through a 0.45 µm membrane filter (Advantec MFS, Inc., Japan), and the obtained residue was the “Washed AC” used in this study. In addition, real circle water from an electrical discharge machining apparatus was obtained from Uehara sei shoji Co. Ltd., Japan.

Properties of the AC

The characteristics of the AC were determined by the following method. Electron microscope images were obtained using a SU-1510 (SEM, JEOL, Japan), and the functional groups were measured by a FT-IR–460Plus (JASCO, Japan). X-ray diffraction (XRD) analysis was performed by MiniFlex II (Rigaku, Japan); specific surface area and pore volume were measured by a NOVA 4200e specific surface analyzer (Yuasa Ionics, Japan). The cation exchange capacity (CEC) was determined by the Japanese Industrial Standard (JIS 1478) method. The pH of the solution was measured with a digital pH meter (HORIBA, Ltd, Japan).

Analysis of Real Circle Water

The electrical conductivity of a real circle water, obtained from an electrical discharge machining apparatus, was measured by a multi water quality checker conductivity meter, WA-2017SDJ (Sato Shoji, Japan). Concentrations of sodium, potassium, magnesium, calcium, zinc, copper, manganese, and silicon ions were measured by an inductively coupled plasma optical emission spectrometry, iCAP-7600 (ICP-OES, Thermo Fisher Scientific Inc., Japan). Concentrations of fluoride, chloride, nitrate, and sulfate ions were measured by ion chromatography (DIONEX ICS-900, Thermo Fisher Scientific, USA). The measurements were performed using the IonPac AS12A system (4×200 mm, Thermo Fisher Scientific, USA). The mobile phase and regenerant comprised 2.7 mmol/L Na2CO3 + 0.3 mmol/L NaHCO3 and 12.5 mmol/L H2SO4, respectively. The flow rate was 1.5 mL/min at ambient temperature. The micro membrane suppressor was an AMMS 300 system (4 mm, Thermo Fisher Scientific, USA).

Adsorption Isotherms

AC (0.05 g) was added to a zinc ion solution at 5-100 mg/L (50 mL). The suspension was shaken at 100 rpm for 2 h at 10, 25, and 50°C. The sample solution was filtered through a 0.45 µm membrane filter, and the filtrate concentration of zinc ion was measured by ICP-OES. The amount of zinc ion adsorbed was calculated using Eq. (1).

q = (C0Ce) / VW           (1)

where q is the amount adsorbed (mg/g), C0 is the initial concentration, Ce is the equilibrium concentration (mg/L), V is the solvent volume (L), and W is the weight of the adsorbent (g). The data are expressed as the mean±standard error (S.E.) of the mean (n=3–6).

Effect of Contact Time and pH on the Adsorption of Zinc Ion onto the AC

To evaluate the contact time, AC (0.05 g) was added to a zinc ion solution at 50 mg/L (50 mL). The suspension was shaken at 100 rpm for different time intervals (0.17, 0.5, 2, 6, 22, and 24 h) at 25°C. To evaluate the pH, the adsorption experiments were performed with 0.05 g of AC and a zinc ion solution at 50 mg/L (50 mL) at different pH values (pH: 3, 4, 5, and 6). The pH level was adjusted by 0.1 mol/L of hydrochloric acid. The amount of zinc ion adsorbed in each case was calculated using Eq. (1). The data are expressed as the mean±standard error (S.E.) of the mean (n=3–6).

Applications of AC at Different Conditions

AC (0.1 g or 0.2 g as condition I or condition II, respectively) and Washed AC (0.1 g as condition III) were added to real circle water (100 mL). The suspensions were shaken at 250 rpm for different time intervals (0.17, 0.5, 1, 2, 6, 22, and 24 h) at room temperature. In addition, an ion exchange rain (Uehara sei shoji Co., Ltd., Japan) was used as the control in this experiment. Changes in each concentration, pH, and electrical conductivity were evaluated by the aforementioned methods.

Finally, to evaluate the application of AC in the real field, the changes in each concentration, pH and electrical conductivity were measured by the aforementioned methods using a column with Washed AC (diameter×height: 2.5 cm×10 cm). Washed AC (3.0 g) was added up to a level of 1 cm above the base of the column. The approximate condition for the column experiment was as follows: space velocity (S.V.), 61.1 1/h; linear velocity (L.V.), 0.61 m/h; flow rate, 5 mL/min (down flow). The column experiment was performed at ambient (room) temperature, and the volume of real circle water was 500 mL. The data are expressed as the one-time measurement.

RESULTS AND DISCUSSION

Properties of Adsorbent

The surface roughness of the AC was confirmed in this study (Fig. S1). The physicochemical properties of the AC were evaluated. The specific surface area, micropore volume, mesopore volume, and macropore volume were 125.0 m2/g, 0.7 μL/g, 172.6 μL/g, and 13.7 μL/g, respectively. The cation exchange capacity at pH 5 and pH 10 were 56.2 and 67.2 cmol/kg, respectively. The FT-IR of AC is shown in Fig. S2. The bands at 3699 cm-1 (Al-OH-Al stretching) and 915 cm-1 (Al-OH-Al binding) are indicative of dioctahedral smectite. The peaks at 3435 cm-1 (H-O-H stretching) and at 1637 cm-1 (H-O-H bending) indicate the presence of water. In addition, the broad at 1034 cm-1 represents the Si-O-Si stretching vibration.10,12) Finally, the chemical structure was confirmed (Fig. S3). The XRD pattern of the AC shows mainly the presence of montmorillonite. These results indicate that the surface properties of the AC have similar trends for raw and acid-treated bentonites.12)

Concentration and Electrical Conductivity

Decreasing the electrical conductivity in the circle water is one of the goals of this study. To this aim, we firstly measured the concentration and electrical conductivity of real circle water in wire cut condition (Table 1). Concentrations (and resulting contributions to the overall electrical conductivity) of Mg2+, Zn2+, and Cl- were higher than those of other ions. The electrical conductivity of the wire cut water was 60.6 µS/cm. Mg2+ and Cl- are usually present in tap water, yet it is Zn2+ that highly contributes to the electrical conductivity (12.5 µS/cm, 21%). Therefore, removal of Zn2+ from wire cut water is important for decreasing electrical conductivity, thus we focused in our experiments on removing Zn2+ from the aqueous solution system.

Table 1. Concentration and Electrical Conductivity of Real Circle Water in Wire Cut Condition
Elements Concentration
(mg/L)
Electrical conductivity
(µS/cm)
Na+ 1.38 3.01
K+ 0.23 0.44
Mg2+ 3.73 16.3
Ca2+ 2.13 6.34
Zn2+ 7.76 12.5
Cu2+ 2.24 3.89
Mn2+ 0.10 0.20
Si 0.27 0.00
F- 1.61 4.69
Cl- 4.62 9.96
NO3- 0.88 1.01
SO42- 1.39 2.78

Adsorption Capacity of Zn2+ onto the AC

The adsorption isotherms of Zn2+ onto the AC at different temperatures are shown in Fig. 1. The adsorbed amounts positively depended on temperature (10 < 25 < 50°C). However, this trend was not confirmed at equilibrium concentration of over 40 mg/L in the case of adsorption isotherm at 25°C. Previous studies reported that Zn2+ adsorption in bentonite clay or in special modified raw bentonite was approximately 2–3 or 0.4–2.3 mg/g, respectively.13,14) In this study, the adsorbed amount was approximately 4.0 mg/g. Therefore, the adsorption capability of the AC is sufficient for removing Zn2+ from an aqueous solution.

Fig. 1

Adsorption Isotherms of Zinc Ion onto the AC at Different Temperatures

Initial concentration: 5~100 mg/L, solvent volume: 50 mL, adsorbent: 0.05 g, contact time: 2 h, temperature: 25°C, stirring: 100 rpm, pH in the solution: 5.7~6.5, the data are expressed as the mean±standard error (S.E.) of the mean (n=3–6).

The adsorption isotherms were evaluated by the Langmuir (2) or Freundlich (3) equations.

Ce/qe = 1/aWs + Ce/Ws           (2)

where qe is the adsorption capacity at equilibrium (mg/g), Ce is the equilibrium concentration of Zn2+ (mg/L), and Ws and a are the maximum adsorption capacity (mg/g) and the equilibrium adsorption constant (L/mg), respectively.

log qe = log K + 1/n log Ce           (3)

where K is a constant indicative of the relative adsorption capacity of AC, and n is a constant indicative of the intensity of the adsorption and varies with surface heterogeneity.15)

Table 2 shows the Langmuir and Freundlich constants for the adsorption of Zn2+ onto the AC. The correlation coefficient of Freundlich (0.961–0.982) provides a better fit than that of Langmuir (0.689–0.996). The Freundlich-type isotherm hints toward surface heterogeneity. In addition, Zn2+ was easily adsorbed on the AC when 1/n was in the range of 0.1–0.5 but not when 1/n > 2. These results suggest that Zn2+ adsorption readily occurred when 1/n < 2 (0.35–0.88).16)

Table 2. Langmuir and Freundlich constants for the adsorption of zinc ions onto the AC
Temperatures (°C) Langmuir constants Freundlich constants
Ws
(mg/g)
a
(L/mg)
r logK 1/n r
10 10.8 0.01 0.689 -1.06 0.88 0.982
25 4.49 0.04 0.922 -0.31 0.45 0.961
50 4.90 0.13 0.996 0.03 0.35 0.966

Effect of Contact Time and pH on the Adsorption of Zn2+

Figure 2 shows the effect of contact time on the adsorption of Zn2+ onto the AC. The adsorption equilibrium was reached within 30 min. Previous studies reported that the adsorption equilibrium of Zn2+ onto natural bentonite or kaolin was attained within 25 h or 80 min, respectively.17,18)

Fig. 2

Effect of Contact Time on the Adsorption of Zinc Ion onto the AC

Initial concentration: 50 mg/L, solvent volume: 50 mL, adsorbent:0.05 g, contact time: 0~24 h, temperature: 25°C, stirring: 100 rpm, pH in the solution: 5.8, the data are expressed as the mean±standard error (S.E.) of the mean (n=3–6).

The adsorption kinetics were used to evaluate the rate of adsorption and the adsorption mechanism.19,20) Kinetic data were investigated by applying the pseudo-first-order (Eq. (4)) and pseudo-second-order (Eq. (5)) models, as follows:

ln (qeqt)/qe = - k1t           (4)

t/qt = 1/(k2qe2) + t/qe           (5)

where qe and qt correspond to the amount of Zn2+ adsorbed at equilibrium and at time t (mg/g), respectively; k1 is the pseudo-first-order rate constant (1/h); and k2 is the pseudo-second-order rate constant (g/mg/h).

The correlation coefficient of the pseudo-second-order model (0.999) was higher than that of the pseudo-first-order model (0.417). In addition, the value of qe,exp (2.93 mg/g) was closer to that of qe,cal in the pseudo-second-order kinetic model (2.79 mg/g) than in the first-order model (0.23 mg/g). These results indicate that the adsorption of Zn2+ is controlled by chemical sorption (chemisorption), involving valence forces.21)

Subsequently, the effect of pH on the adsorption of Zn2+ onto the AC was evaluated (Fig. 3). It was observed that the adsorption capacity of Zn2+ onto the AC increased with the increasing pH of the solution. At lower pH values, the decreasing of adsorption capacity might be attributed to the electrostatic repulsion between Zn2+ and the protonated surface functional group. However, at higher pH values, the adsorption capacity was enhanced due to an increase of the deprotonated surface functional group (Scheme is below).11)

S-OH + M2+ ⇄ S-O-M + H+

S-O- + M2+ ⇄ S-O-M

where S represents the active surface functional groups (silanol or aluminol site) onto AC, and M represents the metal ions. In this study, similar trends were observed compared to previous studies.

Fig. 3

Amount of Zinc Ion Adsorbed onto the AC at Different Values of pH

Initial concentration: 50 mg/L, solvent volume: 50 mL, adsorbent: 0.05 g, contact time: 2 h, temperature: 25°C, stirring: 100 rpm, pH in the solution: 3.0~6.0, the data are expressed as the mean±standard error (S.E.) of the mean (n=3–6).

Application of AC in Real Circle Water

Table 3 shows the changes in element concentrations, pH, and electrical conductivity with the AC (Condition I). The AC treatment was performed to decrease the concentration of Zn2+ (8.11→3.62 mg/L) and Cu2+ (2.59→0.32 mg/L). However, we also observed increases in the concentration of Si (0.23→3.40 mg/L) and SO42- (0.79→6.90 mg/L). These results suggest that Zn2+ and Cu2+ were adsorbed onto the AC, whereas Si and SO42- were desorbed from it during the treatment. Finally, it can be concluded that the electrical conductivity of real circle water can be reduced approximately 27% by the AC treatment. In the following experiments, we focused on the concentrations of Zn2+ and SO42-, and on the electrical conductivity (Fig. 4 and Table 4).

Table 3. Changes in Element Concentrations, pH, and Electrical Conductivity with the AC
Time (h) 0 0.17 0.5 1 2 6 22 24
Elements (mg/L)
Zn2+ 8.11 5.11 4.57 4.28 4.02 3.84 3.72 3.62
Cu2+ 2.59 0.53 0.41 0.32 0.29 0.29 0.35 0.32
Mn2+ 0.10 0.08 0.07 0.07 0.07 0.07 0.06 0.07
Al3+ 0.02 0.00 0.01 0.01 0.03 0.05 0.09 0.08
Si 0.23 0.26 0.33 0.44 0.75 1.32 3.23 3.40
Na+ 0.86 0.89 0.88 0.81 0.90 0.84 0.95 0.91
K+ 0.25 0.52 0.47 0.42 0.45 0.35 0.50 0.41
Mg2+ 4.71 3.51 3.32 3.20 3.12 3.01 2.96 2.91
Ca2+ 1.95 1.72 1.67 1.49 1.54 1.38 1.35 1.28
F- 1.52 1.50 1.56 1.55 1.58 1.40 1.54 1.53
Cl- 1.91 1.90 1.96 1.86 2.06 2.10 2.14 2.84
NO3- 0.18 0.16 0.18 0.17 0.44 0.25 0.23 0.25
SO42- 0.79 6.55 6.80 6.79 6.88 6.38 6.44 6.90
pH 7.1 6.8 6.8 6.7 6.7 6.6 6.6 6.5
Electrical conductivity (μS/cm) 72.7 62.2 59.7 57.2 55.1 52.8 52.9 53.2

Solvent volume: 100 mL, adsorbent: 0.1 g, contact time: 0~24 h, temperature: room temperature, stirring: 250 rpm, pH in the solution: 7.1

Fig. 4

Changes in the Concentration of Zinc Ion and Sulfate Ions Using the AC in Real Circle Water

Solvent volume: 100 mL, adsorbent: 0.1~0.2 g, contact time: 0~24 h, temperature: room temperature, stirring: 250 rpm, pH in the solution: 6.8~7.5, the data are expressed as the one-time measurement.

Table 4. Changes in the Electrical Conductivity in Different Conditions
Time (h) Electrical conductivity (μS/cm)
Condition I Condition II Condition III Ion exchange resin
0 72.7 77.0 72.3 71.9
0.17 62.2 66.4 48.6 66.5
0.5 59.7 65.5 47.0 54.1
1 57.2 63.6 43.7 48.2
2 55.1 65.6 39.7 23.9
6 52.8 66.3 35.8 3.4
22 52.9 66.6 36.2 2.8
24 53.2 66.0 36.0 3.4

Amount adsorbent of virgin AC is 0.1 g or 0.2 g in condition I or condition II, and amount adsorbent of washed AC is 0.1 g in condition III.

Solvent volume: 100 mL, contact time: 0~24 h, temperature: room temperature, stirring: 250 rpm

We confirmed the increase of SO42- after the AC treatment, and therefore washed the AC with distilled water to prevent the release of SO42- from the AC. The removal rate of Zn2+ from real circle water was similar for Conditions I-III. However, the released concentration of SO42- from the AC was in the following order: Condition III < Condition I < Condition II. This phenomenon indicates that the washed treatment with distilled water is useful for the removal of SO42- from the AC. In addition, the reduction rate of the electrical conductivity after 24 h was in the order: Condition II (14%) < Condition I (27%) < Condition III (50%) < Ion exchange resin (95%). However, Condition III shows the ability of reducing the electrical conductivity in a short time, i.e. within 10 min. Therefore, we could establish a very cheap and rapid treatment for the removal of electrical conductivity.

Finally, the column packed with washed AC was used to exemplify a real application of the AC in field conditions (Table 5). The experimental results confirmed that the adsorption capability of Zn2+ was higher (7.93→1.51 mg/L), and the released SO42- from the AC was lower (1.22→3.66 mg/L) compared to untreated AC. Moreover, the reduction rate of the electrical conductivity was approximately 47%. This result suggests that the column treatment packed with washed AC is useful for reducing the electrical conductivity by ion removal.

Table 5. Changes in Element Concentrations, pH and Electrical Conductivity Using a Column Containing Washed AC
Time (h) 0 0.17 0.5 1 2 6 22 24
Elements (mg/L)
Zn2+ 7.93 7.20 4.71 1.73 1.30 1.12 1.56 1.51
Cu2+ 2.65 3.02 1.31 0.13 0.58 0.14 0.61 0.60
Mn2+ 0.10 0.10 0.06 0.03 0.03 0.04 0.03 0.03
Al3+ 0.00 0.00 0.00 0.02 0.04 0.06 0.04 0.03
Si 0.23 0.36 0.46 0.64 0.75 1.39 3.41 3.56
Na+ 0.70 0.68 0.63 0.60 0.64 0.57 0.54 0.56
K+ 0.78 0.71 0.84 1.50 0.91 0.68 0.65 0.52
Mg2+ 4.83 4.37 2.97 1.37 1.24 1.22 1.26 1.23
Ca2+ 1.91 1.93 1.41 0.85 0.89 0.84 0.68 0.72
F- 0.07 0.07 0.06 0.06 0.07 0.06 0.07 0.07
Cl- 2.70 2.53 2.46 3.39 2.96 2.74 2.37 2.63
NO3- 0.28 0.33 0.21 0.21 0.20 0.18 0.19 0.22
SO42- 1.22 3.61 2.84 3.16 3.45 3.58 3.69 3.66
pH 6.8 6.6 6.5 5.8 5.2 4.8 4.9 4.8
Electrical conductivity (μS/cm) 69.9 66.9 51.9 36.9 39.5 41.7 37.1 36.9

Solvent volume: 500 mL, flow rate: 5mL/min, S.V.: 61.1 1/h, L.V.: 0.61 m/h

In summary, an AC was prepared for removing Zn2+ from wire cut water. The physicochemical properties of the AC were investigated, and the adsorption capability was evaluated in this paper. The AC has a montmorillonite-like structure, and a specific surface area of 125.0 m2/g. The amount of Zn2+ adsorbed onto the AC increased with the temperature increasing (10–50°C). The experimental data were fitted to the Freundlich equation (correlation coefficient: 0.961–0.982). Moreover, the adsorption capability was found to be affected by the contact time and pH of the solution. Adsorption equilibrium of Zn2+ onto the AC was reached within 30 min. Adsorption rate data were shown to fit better to the pseudo-second-order model (correlation coefficient: 0.999) than to the pseudo-first-order model (correlation coefficient: 0.417).

Additionally, the AC was proven to be able to reduce the electrical conductivity of wire cut water. The reduction of electrical conductivity using washed AC was higher (50%) than that achieved using untreated AC (27%). A column treatment packed with washed AC was useful for reducing the electrical conductivity (47%). Taken together, these results indicate that washed AC could have a high potential for reducing the electrical conductivity (through Zn2+ removal) from wire cut water.

Conflict of interest

The authors declare no conflict of interest.

REFERENCES
 
© 2019 The Pharmaceutical Society of Japan

BPB Reports applies the Creative Commons Attribution (CCBY) license to works we published. The license was developed to facilitate open access - namely, free immediate access to, and unrestricted reuse of, original works to all types. Under this license, authors agree to make articles legally available for reuse, without permissions of fees, for virtually any purpose. Anyone may copy, distribute, or reuse these articles, as long as the author and original source are properly cited.