OCCLUSION OF FULL CAST CROWN AT THE INTERCUSPAL POSITION
Shigeo HASEGAWAEiichi BANDOBatsuhei TANAKATsuneo TABATA
Author information
JOURNAL OPEN ACCESS

1981 Volume 28 Issue 2 Pages 53-60

Details
Abstract
The IP-Checker type MS capable of measuring the height of a crown at the intercuspal position (IP) was invented. The following observations were obtained. 1. The intercuspal position is stable within 5 µm 2. The intercuspal position shows a higher stability under slight biting than under heavy biting Under this condition, the teeth show a displacement of about 20 µm by the distortion of the periodontal membrane. 3. The crown made by the ordinary procedure is about 300 µm higher at the intercuspal position. Therefore, an occulusal adjustment is always necessary. 4. With the current method of occlusal adjustment adjustment of the crown to a definite height with the maximum error of 10 µm is possible in the oral cavity.