BUNSEKI KAGAKU
Print ISSN : 0525-1931
Notes
Qualitative Analysis for Trace Amounts of Organocompounds Derived from Constitutional Materials of Electrolytic Compartments During Generation of an Acidic Electrolyzed Water
Toshikazu TakenouchiShouhei Hayase
Author information
JOURNAL FREE ACCESS

2010 Volume 59 Issue 9 Pages 817-821

Details
Abstract
The solution produced in the anolyte compartment by the electrolysis of a dilute NaCl solution, ie., acidic electrolyzed water was analyzed by a gas chromatograph/mass spectrometer (GC/MS). As a result, organochlorinated compounds that are derived from constitutional materials of electrolytic compartments, and silicone compounds originated from O-ring of electrolytic compartments were detected. We examined the surfaces of ABS resin and a diaphragm, which were immersed in acidic electrolyzed water for 4 weeks, by scanning electron microscopy, slight changes of the surfaces were observed. It is likely that acidic electrolyzed water that contains free chlorine deteriorates constitutional materials of electrolytic compartments.
Content from these authors
© The Japan Society for Analytical Chemistry 2010
Previous article Next article
feedback
Top