2025 Volume 78 Issue 1 Pages 187-195
A fundamental study was conducted to establish a measurement method for the fixed amount of CO2 in the cementitious materials. The fixed amount of CO2 in the calcium compounds that simulate cement hydrates containing monocarbonate was measured by the TG-DTA method and TOC method, and their values were compared. As a result, the TOC method provided highly accurate measurement values under the conditions of a sample size of 150μm or less and dripping amount of pure water of 4mL/g or more on the sample. The measurement values of the fixed amount of CO2 in monocarbonate were generally accurate by the TOC method, while those by the TG-DTA method showed smaller values than the theoretical ones.