Concrete Journal
Online ISSN : 2186-2753
Print ISSN : 0387-1061
ISSN-L : 0387-1061
Bottom-Up Concreting into Steel Tube Column Filled with Ultra High-Strength Concrete Using Silica Fume
T. YonezawaT. OkunoK. MitsuiN. NumakuraT. ÔuraM. Sato
Author information
JOURNAL FREE ACCESS

1993 Volume 31 Issue 12 Pages 22-33

Details
Abstract
In this technical report outline of the first application, in Japan, of the ultra highstrength concrete with design strength of 600 kgf/cm2 using silica fume to a super high-rise building is presented.The structure of the 39 story building is a steel frame with steel tube colums filled with the ultra high-strength concrete. The concrete was pumped into the columns from the bottom up to 61.9 m at a time. For the production of the silica fume concrete, a ready mixed concrete plant that enables the use of as-produced silica fume was developed. Trial mixing tests, pumping tests and bottom-up concreting tests were carried out before construction. The outline of the plant and the results of the actual construction are presented along with the preliminary tests.
Content from these authors
© Japan Concrete Institute
Previous article Next article
feedback