Journal of Environment and Safety
Online ISSN : 2186-3725
Print ISSN : 1884-4375
ISSN-L : 1884-4375
Proceedings of ACSEL2018, The 5th Asian Conference on Safety and Education in Laboratory November 21-22, 2018
Generation mechanism of 1,4-dioxane in the exhaust gas from an industrial waste incineration facility
Yasuro Fuse, Takashi Nagaya, Ichiro Aizawa
Author information
JOURNAL FREE ACCESS

2019 Volume 10 Issue 2 Pages 49-52

Details
Abstract

The mean concentration of 1,4-dioxane in the atmosphere is 0.029 µg/m3. This value is higher than those of water and food. At the industrial waste incineration facility targeted in this study, 1,4-dioxane was generated when the exhaust gas was passed through a dry process neutralizing apparatus with a lime coated bag filter. It is conjectured that the 1,4-dioxane is generated from the lime on the bag filter. Thus, the 1,4-dioxane generation mechanism was investigated via a simulation experiment where the dry process neutralizing apparatus was replicated.

Content from these authors
© 2019 Academic Consociation of Environmental Safety and Waste Management,Japan
Previous article Next article
feedback
Top